• 제목/요약/키워드: x-y-z stage

검색결과 83건 처리시간 0.027초

VCM을 이용한 리소그래피용 레티클 스테이지의 설계 및 기구학적 해석 (Design and Kinematic Analysis of the Reticle Stage for Lithography Using VCM)

  • 오민택;김문수;김정한
    • 한국공작기계학회논문집
    • /
    • 제17권3호
    • /
    • pp.86-93
    • /
    • 2008
  • This paper presents a design of the reticle stage for lithography using VCM(Voice Coil Motor) and kinematic analysis. The stage has three axes for X,Y,${\theta}_z$, those actuated by three VCM's individually. The reticle stage has cross coupled relations between X,Y,${\theta}_z$ axes, and the closed solution of the forward/inverse kinematics were solved to get an accurate reference position. The reticle stage for lithography was designed for reaching both high accuracy and long stroke, which was $0.1{\mu}m$ (X,Y)/ $1{\mu}rad({\theta}_z)$ accuracies and relatively long strokes about 2mm (X,Y) and 2 degrees(${\theta}_z$). Also this research presents a rotational compensation algorithm for the precision gap sensor for the stage. Simulation results show the overall performance of the whole algorithm and the improvement quantity of the rotational compensation algorithm.

Experiments of a Novel Magnetic Levitation Stage for Wide Area Movements

  • Jeon, Jeong-Woo;Caraiani, Mitica;Oh, Hyeon-Seok;Kim, Sung-Shin
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.558-563
    • /
    • 2012
  • In this paper, a novel planar type magnetic levitation system without other assistant devices is proposed and it can move with 6 degree of freedom (X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$) in wafer size as well as in nano scale positioning.The mover is composed with 2-D Halbach permanent magnet array and the stator is composed with $10{\times}10$ coil arrays.It was composed in laboratory and tested with short stroke (4 [mm]) and long stroke (160 [mm])movements. The errors of short movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}3urad$, ${\pm}2urad$, ${\pm}1urad$]The errors of long stroke movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}1.5urad$, ${\pm}2urad$, ${\pm}0.5urad$].

Development of Tele-operation system Based on the Haptic Interface

  • Lee, Jong-bae;Chung, Joong-ki;Moon, Chan-woo;Lim, Joon-hong
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.236-239
    • /
    • 2003
  • In this paper, we investigate the issues for the design and implementation of tele-operation system based on the haptic interface. Here, the 3-DOF haptic device and the x-y-z stage are employed as master controller and slave system respectively. In this master-slave system, the force feedback algorithm, the modeling of virtual environments and the control method of x-y-z stage are proposed. In this paper, inernet network is used for data communication between master and slave. We construct virtual environment of the real convex surface from the force-feedback in controlling the X-Y-Z stage and getting the force applied by the 3-DOF haptic device.

  • PDF

Design and Implementation of Tele-operation system based on the Haptic Interface

  • Lee, Jong-Bae;Lim, Joon-Hong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권2호
    • /
    • pp.161-165
    • /
    • 2003
  • In this paper, we investigate the issues on the design and implementation of tele-operation system based on the haptic interface. Here, the 3-DOF haptic device and the X-Y-Z stage are employed as master controller and slave system respectively. For this master-slave system, the force feedback algorithm, the modeling of virtual environments and the control method of X-Y-Z stage are presented. In this paper, internet network is used for data communication between master and slave. We construct virtual environment of the real convex surface from the force-feedback in controlling the X-Y-Z stage and measuring the force applied by the 3-DOF haptic device.

초정밀 마이크로 위치결정 스테이지의 제작 및 평가 (Experiment of the Precision micro-positioning stage)

  • 한창수;백석;노명규;이찬홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.244-247
    • /
    • 2002
  • The performance of the precision micro-positioning 4-dof stage is presented. The compact design utilizes the monolithic mechanism to achieve the translation in the Z axis and rotation in the $\theta$ z, $\theta$ x and $\theta$ y axes with high stiffness and high damping. Hysteresis, nonlinearity, and drift of the piezoelectric effects are improved by incorporating the sensors in a feedback control. Experiments demonstrate that the micro-positioning stage is capable of 2nm resolution over the travel range of 25$\mu\textrm$ m in the Z axis, 0.0l7 $\mu\textrm$ rad resolution over the 170$\mu\textrm$ rad in the $\theta$ z and 0.011 $\mu\textrm$ rad resolution over the $\mu\textrm$ rad in the $\theta$ x and $\theta$ y axes. The cross-axis interferences among the axes are at a noise range. This stage is available for positioning error compensation of the XY stage with large stroke.

  • PDF

Bioimpedance Changes in Rats with CCl4-Induced Liver Fibrosis

  • Heo, Jeong;Jung, Dong-Keun
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.71-76
    • /
    • 2011
  • To characterize the relationship between the stage of hepatic fibrosis and bioimpedance, several electric parameters were estimated in rats with $CCl_4$-induced liver fibrosis. Thirty three Sprague-Dawley rats were intraperitoneally injected with a $CCl_4$-mineral oil mixture (1:1, 0.2 mL/100 g) twice a week for 8 weeks. The resistance(R), reactance(X), impedance(Z), and dissipation factor(D) between 1 kHz and 100 kHz were then evaluated in the livers of the rats under pentobarbital anesthesia using an HP4294A Impedance Analyzer. The rats were killed 2, 4, 6, and 8 weeks later, and their livers were classified in accordance with Ishak's scoring system. R, X, and Z changed in accordance with the progression of hepatic fibrosis and the changes were greater at lower frequencies than at higher frequencies. In comparison, the D spectrum was biphasic; D increased initially then decreased with increasing frequency. All of the parameters(R, X, Z, and D) changed in accordance with the stage of fibrosis in the livers, but D changed specifically with the progression of fibrosis. These results indicate that hepatic fibrosis may be evaluated by determining the changes in D.

3축 마이크로 공작기계용 자기예압 공기베어링 스테이지의 정, 동적 특성 (Static and Dynamic Characteristics of Magnetically Preloaded Air Bearing Stage for a 3-Axis Micro-Machine Tool)

  • 노승국;;;박종권
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.468-472
    • /
    • 2005
  • In this paper, the static and dynamic stiffness of the air bearing stage for micro-micro machine tool are examined experimentally. For stiffness and precision concerns, air bearing stages are adapted for 3-axis micro-milling machine which is size of $200x200\;mm^2$. The air bearings in the stage are preloaded by permanent magnets to achieve desired bearing clearance and stiffness for vertical direction. As the stiffness of the air bearing is primary interests, static stiffness test were performed on XY stage in Z direction and Z column in Y direction. Dynamic test were performed on XY stage and Z column, respectively. Both static and dynamic tests were performed in different air pressure conditions. The vertical stiffness of XY stage is about 9 N/ pm where Y stiffness of Z column is much smaller as $1\;N/{\mu}m$ because of the large moment generated by Y force on the column.

  • PDF

초정밀 마이크로 위치결정 스테이지의 설계 (Design of the precision micro-positioning stage)

  • 한창수;김경호;이찬홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.539-542
    • /
    • 1997
  • We present a micro-positioning stage that has minimized geometrical error and can drive in the 4-axis. This stage divided into two parts: $Z\theta_x$ $\theta_y$, motion stage and$\theta_z$ motion stage. These stages are constructed in flexure hinges, piezoelectric actuators and displacement scnsors. The dynamic model for each stage is obtained and their FE (finite element) models are made. Using the Lagrange's equation, the motion of equation is found. Through the parametric analysis and FE analysis, sensitiv~ty of the design parameters is executed. Finally, fundamental frequencies, maximum stress, and displacement sensitivity for each stage are obtained. We expect that this micro-positioning stage be a useful micro-alignment device for various applications.

  • PDF

플렉셔 힌지 기반 6-자유도 초정밀 위치 결정 스테이지의 기구학 해석 (Kinematic Analysis of a 6-DOF Ultra-Precision Positioning Stage Based on Flexure Hinge)

  • 신현표;문준희
    • 한국정밀공학회지
    • /
    • 제33권7호
    • /
    • pp.579-586
    • /
    • 2016
  • This paper describes kinematic analysis of a 6-degrees-of-freedom (DOF) ultra-precision positioning stage based on a flexure hinge. The stage is designed for processes which require ultra-precision and high load capacities, e.g. wafer-level precision bonding/assembly. During the initial design process, inverse and forward kinematic analyses were performed to actuate the precision positioning stage and to calculate workspace. A two-step procedure was used for inverse kinematic analysis. The first step involved calculating the amount of actuation of the horizontal actuation units. The second step involved calculating the amount of actuation of the vertical actuation unit, given the the results of the first step, by including a lever hinge mechanism adopted for motion amplification. Forward kinematic analysis was performed by defining six distance relationships between hinge positions for in-plane and out-of-plane motion. Finally, the result of a circular path actuation test with respect to the x-y, y-z, and x-z planes is presented.

네트웍 기반 원격제어시스템의 설계 (Design of Haptic Tele-operation System)

  • 박창우;구자일;엄우용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1171-1172
    • /
    • 2008
  • In this paper, we investigate the issues on the design and implementation of tele-operation system based on the haptic interface. Here, the 3-DOF haptic device and the X-Y-Z stage are employed as master controller and slave system respectively. For this master-slave system, the force feedback algorithm, the modeling of virtual environments and the control method of X-Y-Z stage are presented. In this paper, internet network is used for data communication between master and slave.

  • PDF