• Title/Summary/Keyword: window area's rate

Search Result 24, Processing Time 0.025 seconds

The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio (차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가)

  • Jang, Cheol-Yong;Han, Hye-Sim;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

Energy Performance Analysis the Common House Pansang Type and Tower (공동주택의 판상형과 타워형 에너지 성능 비교 분석)

  • Yoon, Sung-Meen;Lee, Kyung-Hee;Ahn, Young-Chull
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.57-64
    • /
    • 2013
  • This study focus on the analysis of the energy performance in accordance with apartment houses arrangement type by using Ecotect Analysis. Korea, energy-poor country, the rate of dependence on imports amount to 94%, have to reduce energy consumption part of building except in industry and transport which affect the economic. Apartment houses are built in various forms in order to reduce energy, are modelled in each window area ratio, shape, orientation, climate through simulation. Through this study, we can analyze energy performance by form, window area ratio, orientation, climate change and know the optimal elements by the form. In particular, although there have been studied research on the window area ratio and research related to the arrangement form, determined that the information on the regional climate characteristics and the direction of placement is less than existing research. To supplement those problem, adding to seven direction(West, S-60-W, S-30-W, South, S-30-E, S-60-E, East) and climatic element(southern region) is characteristic of this study. The form of apartment houses was modelled for apartment houses built in the 10 years since. And each modeling were analyzed by Ecotect Analysis.

A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating (건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

A study on the Insulation Performance of the Super Window applied to building energy efficiency rating (초단열 슈퍼윈도우의 건물에너지효율등급 적용 연구)

  • Jang, Cheol-Yong;Kim, Chi-Hoon;Ahn, Byung-Lip
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.205-210
    • /
    • 2009
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend. According to the flow of energy is lost from the building, will be achieved through the walls and roof and windows. Among these, the window through the loss of about 45% of the entire building is big enough to rate. In addition, the building regulation U-value Limitation of window is $3.3W/m^2$ K in southern regions, while U-value Limitation of wall is $0.35{\sim}0.58W/m^2$ K. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1)Thermal performance of insulated Super Window measured as $1.44W/m^2$ $^{\circ}C$ 2)Required energy for heating was cut down about 5.3% from 266.99 $MJ/m^2$ yr to 252.85 $MJ/m^2$ yr 3)Super Window's reduction rates increased 4.1% from 31.48% to 35.58% when it is compared to normal windows. 4)Building energy efficiency rating elevated from 2nd rating to 1st rating.

  • PDF

Balcony window style photo-voltaic(PV) system design by considering resident's residential time rate - Focus on the design of apartment building balcony window PV system and it's performance - (거주자 주택 점유율을 고려한 공동주택 발코니 PV시스템 디자인 - 공동주택의 발코니 PV시스템 디자인과 성능검증 중심으로 -)

  • Chin, Kyung-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • In case of general residential house, photovoltaic can be installed at roof, wall, and any other places. But, in case of apartment building, there has not enough roof space to install photovoltaic panels to supply enough electricity. Actually, apartment building roof and facade wall (exclude the balcony window space) is not enough space to produce and supply the electricity to residents by installing PV panel. Generally, the space of facade balcony with windows in facade wall at apartment building occupied about $70{\sim}80%$, in all facade space. So, if we could use the balcony and windows space in facade as PV to generating electricity, there could contribute the energy saying. But, PV cell is opacify. So if it installed at front window area in apartment building, residents may have displeasure for that opacity character. But the other hand, residents are not always in house especially in day time that is exactly good time for generating electricity by PV. If we can use PV at the facade balcony with window without collusion of resident's displeasure, there have good attraction to using sustainable energy. Hence, this study suggests the design of facade balcony window style PV by considering resident's living pattern in apartment building. The methods of this study are as follows. At first, this study surveyed to the residents about residential time in their home and asked user demand by Delphi survey. At second, this study designed balcony open style PV system which oriented to the user demand. At third, this study tests designed result performance by computer simulation that compared design result with old design. As a result, For the purpose of satisfying the resident demand, there designed sliding window style which slide the several door systems to the one side. That would be make balcony absolute open scenery to the residents. Hence, the designed system performance results were as follows. When we compare the small apartment and large apartment, smaller one has good performance than larger one. Because resident's residential time characteristic. And that has more good electronic performance than vertical style that is similar to roof style.

A Fundamental Study On the Self-Sufficient Heating Energy for Residential Building (주거용 건물의 난방 에너지 자립을 위한 기초 연구)

  • Son, Sun-Woo;Baek, Nam-Choon;Suh, Seung-Jik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.255-258
    • /
    • 2009
  • Leading developed countries have studied energy self-sufficient houses such as zero or low energy buildings to reduce energy consumption for buildings since the early 1990s. Moreover, some developed countries have actually constructed self-sufficient houses and operated them for demonstration, expanding use of such houses. Korea has also established Zero Energy Solar House(ZeSH) and studied energy independence. Therefore, this study analyzed research result regarding ZeSH, self-sufficient energy house hold of Korea, found out technologies used for heating energy independence, used building interpretation program(ESP_r) to evaluate performance of each factors and analyzed energy reduction quantitatively. Results from the research are as follows: Reduction rate of actual detached house's heating load was also analyzed quantitatively depending on application of each technology. When each factor was applied step-by-step, annual reduction rate of heating load depending on increase in insulation thickness reached 6.6~22.2 %. Annual reduction rate of heating load depending on increase insulation thickness, and change in window heating performance and area ratio reached 31.5 %. Annual reduction rate of heating load through high-sealing and high-insulation depending on change in leakage rate reached 40.0~88.9 %. Annual reduction of heating load, when Mass Wall and attached sun space was applied were applied reached 28.5~39.2 %, respectively.

  • PDF

Properties of CdS Thin Films Prepared by Chemical Bath Deposition as a Function of Thiourea/CdAc2 Ratio in Solution (CBD법으로 제작된 CdS 박막의 thiourea/CdAc2 농도비에 따른 특성)

  • Song, Woo-Chang
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.1
    • /
    • pp.28-32
    • /
    • 2008
  • In this paper CdS thin films, which were widely used window layer of the CdS/CdTe and the CdS/$CuInSe_2$ heterojunction solar cell, were grown by chemical bath deposition, which is a very attractive method for low-cost and large-area solar cells, and the structural, optical and electrical properties of the films was studied. As the thiourea/$CdAc_2$ mole ratio was increased, the deposition rate of CdS films prepared by CBD was increased due to increasing reaction velocity in solution and the optical bandgap was increased at higher thiourea/$CdAc_2$ mole ratio due to larger grain size and continuous microstructure. The minimum resistivity of the films was at thiourea/$CdAc_2$ mole ratio of 3.

A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation (자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sun-Dong
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.325-332
    • /
    • 2014
  • The purpose of this study was to measure the airtightness and Air-Flow Performance for 7th house of small apartment houses adopted window frame-type natural ventilation. All window and living room door is provide with window frame-type natural ventilation, and there is provide with manual controller. As the object of measurement, the 6th type small apartment houses with area of $33m^2$ to $51m^2$ was selected. airtightness performance was measured at the front door using Blower door system. We measured ventilation rate per hour on 50Pa pressure different between inside and outside by the 1st to 6th cases. As a result, when the natural ventilation frame was closed, average amounts are shown as the ventilation rate per hour were 2.27ACH (CASE1). and the result is similar to general apartment house (1.65~4.28ACH). When the natural ventilation frame was open, average amounts are shown as the ventilation rate per hour were 5.87ACH (CASE6). In addition, that's a 3.6ACH increased more than CASE1.

Remedial Measures of Ordinances and Regulations on landscaping at Site Level -The Case of Local Governments in Chollabuk-Do- (대지내의 조경관련 조례와 규제제도의 개선방안 -전라북도의 기초지방자치단체를 중심으로-)

  • 김남희;이명우
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.1
    • /
    • pp.37-47
    • /
    • 2000
  • This research focused on the improved alternatives of the ordinance which practically control the open space in-situ, public open space and landscape construction related to city landscape for the healthy physical and mental life of the city dwellers. The contents of the study are as follows: 1. The special law of Landscape Architecture should be legislated. 2. The portion of landscaping should be changed by up-grading in the Ordinance of Landscape area and planting and the terms of landscape Facilities should include the ecological aspects in it's contents in the law. 3. The administration of local governments should actively lead and support the dwellers to make the roof gardens and the window gardens in the building area of cities or commercial districts which have relatively low rate of green space. 4. Any new construction and restoration of the buildings with preservation of the natural environment and creation of public open space should be given incentive and Set-back space in aesthetic area should have appropriate planting area and facilities in it. 5. Organizing professional landscape evaluation committee and composing evaluation standards are very important because of the contemporary proposition of the establishment of the establishment of ecological space and conservation of urban natural space. Because of the characteristics of Landscape Architecture, the Provisions of landscape Architecture Design and landscape architecture supervision of the specialist should be legislated and the Landscape Architectural Organization should be established within the Government.

  • PDF

Development of an Evaluation Method for a Driver's Cognitive Workload Using ECG Signal (ECG 기반의 운전자별 인지 부하 평가 방법 개발)

  • Hong, Wongi;Lee, Wonsup;Jung, Kihyo;Lee, Baekhee;Park, Jangwoon;Park, Suwan;Park, Yunsuk;Son, Joonwoo;Park, Seikwon;You, Heecheon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.3
    • /
    • pp.325-332
    • /
    • 2014
  • High cognitive workload decreases a driver's ability of judgement and response in traffic situation and could result in a traffic accident. Electrocardiography (ECG) has been used for evaluation of drivers' cognitive workload; however, individual differences in ECG response corresponding to cognitive workload have not been fully considered. The present study developed an evaluation method of individual driver's cognitive workload based on ECG data, and evaluated its usefulness through an experiment in a driving simulator. The evaluation method developed by the present study determined the optimal ECG evaluation condition for individual participant by analysis of area under the receiver operating characteristic curve (AUC) for various conditions (total number of conditions = 144) in terms of four aspects (ECG measure, window span, update rate, and workload level). AUC analysis on the various conditions showed that the optimal ECG evaluation condition for each participant was significantly different. In addition, the optimal ECG evaluation condition could accurately detect changes in cognitive workload for 47% of the total participants (n = 15). The evaluation method proposed in the present study can be utilized in the evaluation of individual driver's cognitive workload for an intelligent vehicle.