• Title/Summary/Keyword: wind generation

Search Result 1,267, Processing Time 0.026 seconds

A Study on Driving Characteristics of combined Generation System 3kW Proto Type Photovoltaic/Wind Generation With Power Storage Apparatus (동력저장기능을 가지는 3kW proto type 태양광/풍력 복합발전시스템의 운전특성에 관한 연구)

  • Park, Se-Jun;Kang, Byung-Bog;Yoon, Jeong-Phil;Lim, Jung-Yeol;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.300-303
    • /
    • 2002
  • Combined generation system of Photovoltaic and wind generation have shortcoming that is different output power according to change of weather. So, the combined generation system is required backup system that such as a storage battery to supply energy, when not enough photovoltaic and wind power source for power supply equally and continually because the energy source is changeable and stable through change of weather as irradiation. temperature, wind speed. wind direction. seasons, etc.

  • PDF

Analysis on the Operation Characteristic of the Combined Electric Power Generation System by Photovoltaic and Wind Energy with Power Storage Apparatu (동력저장장치를 이용한 풍력$\cdot$태양광 복합발전시스템의 특성분석)

  • Lim Jung-Yeol;Lee Jung-Il;Jung Hak-Su;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.58-62
    • /
    • 2001
  • Photovoltaic and wind power generation have an advantage of unlimited and unpolluted amount of energy resource. In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. The system driven by the wind force in this paper consists of a generator, an invertor, batteries and sets for power storage with a spring. In this paper, the operation characteristics of system were analyzed through experiments for a trial product.

  • PDF

A Study on Power Storage Apparatus of combined Generation System 3kW Proto Type Photovoltaic/Wind Generation (3kW proto type 태양광/풍력 복합발전시스템의 전력보상장치에 관한 연구)

  • Park Se-Jun;Kang Byung-Bog;Yoon Jeong-Phil;Lim Jung-Yeol;Cha In-Su
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.74-77
    • /
    • 2002
  • Combined generation system of Photovoltaic and wind generation have shortcoming that is different output power according to change of weather. So, the combined generation system is required backup system that such as a storage battery to supply energy, when not enough photovoltaic and wind power source for power supply equally and continually, because the energy source is changeable and stable through change of weather as irradiation, temperature, wind speed, wind direction, seasons, etc..

  • PDF

Wind Resource Measurements and Analysis at the University Campus (대학교 캠퍼스의 풍력자원 측정 및 분석)

  • Yoon, JaeOck;Kim, Myung-Rae
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.19-24
    • /
    • 2008
  • The wind-power among the new and renewable energies uses the wind, a limitless, clean and pure energy which is available at any place. It requires low installation cost compared to the generation of other renewable energies, and is easy to operate, and furthermore, can be automated for operation. Korea has been taking a great deal of interest in the development of renewable energy generating equipment, specifically wind power generation as the nation has a nearly total reliance on imported petroleum. A measuring poll 30m high was installed at a location with an altitude of 142m above the sea level in order to measure and analyze the wind power potentiality at H University's Asan Campus, and the wind velocity and wind direction were measured for 1 year. As for the wind power resource of the area adjacent to Asan campus, the Weibull Distribution coefficient was C=2.68, K =1.29 at H30m. Weibull Distribution coefficient was modified on the basis of compensated wind velocity (=3.1m/s) at H 60m, and the energy density was $42W/m^2$. AEP 223,750 KWh was forecast based on the simulation of an 800KW grade wind turbine. It is considered that the wind power generation has to be studied further in the inland zone with low wind velocity to cope with the possible exhaustion of fossil fuel and ensure a sustainable environmental preservation.

Technique of Medern Wind Power Generation (현대의 풍력발전 기술)

  • Kim, Jeong-Hwan;Kim, Yoon-Hae;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.62-77
    • /
    • 2001
  • The modern wind turbines are widely used as important natural energy sources for the electric generation in western countries and some Asian nations. They are commercially matured and progressive and clear policy for the more development with higher technical purposes is maintained throughout the world. Modern wind turbines produce nearly 2000 kW output in their largest sizes and this trend increases up to more powerful power and ultimate utilization of wind energy favoured by clean natural energy. This article has the points of reviewing the states of the art of modern wind turbines with their present technical directions toward next generation version. Some descriptionsare given for easy understanding of the turbine components and related fluid mechanics concerned. The general outlines of policy taken over some countries are also introduced.

  • PDF

Development of One Day-Ahead Renewable Energy Generation Assessment System in South Korea (우리나라 비중앙급전발전기의 하루전 출력 예측시스템 개발)

  • Lee, Yeon-Chan;Lim, Jin-Taek;Oh, Ung-Jin;N.Do, Duy-Phuong;Choi, Jae-Seok;Kim, Jin-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.505-514
    • /
    • 2015
  • This paper proposes a probabilistic generation assessment model of renewable energy generators(REGs) considering uncertainty of resources, mainly focused on Wind Turbine Generator(WTG) and Solar Cell Generator(SCG) which are dispersed widely in South Korea The proposed numerical analysis method assesses the one day-ahead generation by combining equivalent generation characteristics function and probabilistic distribution function of wind speed(WS) and solar radiation(SR) resources. The equivalent generation functions(EGFs) of the wind and solar farms are established by grouping a lot of the farms appropriately centered on Weather Measurement Station(WMS). First, the EGFs are assessed by using regression analysis method based on typical least square method from the recorded actual generation data and historical resources(WS and SR). Second, the generation of the REGs is assessed by adding the one day-ahead resources forecast, announced by WMS, to the EGFs which are formulated as third order degree polynomials using the regression analysis. Third, a Renewable Energy Generation Assessment System(REGAS) including D/B of recorded actual generation data and historical resources is developed using the model and algorithm predicting one day-ahead power output of renewable energy generators.

The Study on Correction of Protective Relaying Set Value for the Power Electric Network Paralleled with Wind Farm (풍력전단지의 계통 연계 운전에 따른 보호 계전기 설정치 정정에 관한 고찰)

  • Jang, Sung-Il;Choi, Don-Man;Choi, Jeong-Hwan;Kim, Kwang-Ho;Oh, Jong-Youl;Kim, Joo-Yearl
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.487-490
    • /
    • 2002
  • Wind farm paralleled with electric power network can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the power line with wind farm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator. Consequently, it is difficult to detect the fault happened in the distribution network connected with wind generator. This paper describes the influence of wind turbine generator on the protective relaying system for detecting the fault occurred in a power line network. Simulation results shows that the fault current depends on the fault impedance, location, and the capacity of wind farm and distribution network load.

  • PDF

driving is Possible In low wind, suspension style & oil pressure wind force Power generation system (저풍속도에서도 구동 가능한 현수형 유압식 풍력발전)

  • Choi, June-Young;Choi, Hong-Kyoo;Yum, Sung-Bae;Kim, Young-Kyu;Lee, Chan-Jae;Min, Sung-Jun;Choi, Shin-Gwon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.35-38
    • /
    • 2008
  • Our country need to introduce wind force power generation system that country is small and narrow and becomes positioning with the other country because there are many mountainous regions. power generation efficiency of existent wind force power generation system is droping rapidly and connote much problem in country quality in case of a low wind. We proposed wind force power generation system that use oil pressure motor and synchronous motor that can improve choice of suitable suspension style and country quality in Korean methods special qualify to improve this.

  • PDF

A Study on Design of the Compensation System for Wind Energy Generation by Power Storage Apparatus (동력저장장치를 이용한 풍력발전 보상 시스템 설계에 관한 연구)

  • 윤석암;차인수;백행래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. In addition, most of them have very low usage efficiency because of the characteristic changes of wind. For the solution of these problems and for enough generation regardless of districts and geographical features the rotation energy stored in a spring drives a compact generator and then electric power is stored at battery and supplied to the load continuously according to the lack of wind force. In this paper, the fabricated system consisting of a wind generator and power storage apparatus was introduced and its operation characteristics were analyzed.

  • PDF

Wake Losses and Repositioning of Wind Turbines at Wind Farm (풍력발전단지의 후류손실 및 터빈 재배치에 관한 연구)

  • Park, Kun-Sung;Ryu, Ki-Wahn;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.17-25
    • /
    • 2015
  • The main objective of this study is to predict the wind power generation at the wind farm using various wake models. Modeling of wind farm is a prerequisite for prediction of annual energy production at the wind farm. In this study, we modeled 20 MW class Seongsan wind farm which has 10 wind turbines located at the eastern part of Jeju Island. WindSim based on the computational fluid dynamics was adopted for the estimation of power generation. The power curve and thrust coefficient with meteorology file were prepared for wind farm modelling. The meteorology file was produced based on the measured data of the Korea Wind Atlas provided by Korea Institute of Energy Research. Three types of wake models such as Jensen, Larsen, and Ishihara et al. wake models were applied to investigate the wake effects. From the result, Jensen and Ishihara wake models show nearly the same value of power generation whereas the Larsen wake model shows the largest value. New positions of wind turbines are proposed to reduce the wake loss, and to increase the annual energy production of the wind farm.