• Title/Summary/Keyword: width of device

Search Result 716, Processing Time 0.032 seconds

Magnetocaloric Properties of AlFe2B2 Including Paramagnetic Impurities of Al13Fe4

  • Lee, J.W.;Song, M.S.;Cho, K.K.;Cho, B.K.;Nam, Chunghee
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1555-1560
    • /
    • 2018
  • $AlFe_2B_2$ produced by using a conventional arc melter has a ferromagnetic material with a Curie temperature ($T_C$) of around 300 K, but the arc-melt generates paramagnetic $Al_{13}Fe_4$ impurities during the synthesis of $AlFe_2B_2$. Impurities are brought to cause a decrease in magnetocaloric effects (MCEs). To investigate the effects of $Al_{13}Fe_4$ impurities on MCEs, we prepared and compared ascast and acid-treated samples, where the acid treatment was performed to remove the $Al_{13}Fe_4$ impurities. For the structural analysis, powder X-ray diffraction was carried out, and the measured data were subjected to a Rietveld refinement. The presence of $Al_{13}Fe_4$ impurities in the as-cast sample was observed in the phase analysis measurements. Magnetic properties were investigated by using Superconducting Quantum Interference Device (SQUID) measurements for the as-cast and the acid-treated $AlFe_2B_2$ samples. From isothermal magnetization measurements, Arrott plots were obtained showing that the transition of $AlFe_2B_2$ has a second-order magnetic phase transition (SOMT). The $T_C$ and the saturation magnetization increased for the acid-treated sample due to removal of the paramagnetic impurities. As a consequence, the magnetic entropy change ($-{\Delta}S$) increased in the pure $AlFe_2B_2$ samples, but the full width at half maximum in the plot of $-{\Delta}S$ vs. T decreased due to the absence of impurities.

Improvement of the Directivity of a Doppler Log Using Linear Transducer Array (직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구)

  • 신형일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

Electromagnetic Micro x-y Stage for Probe-Based Data Storage

  • Park, Jae-joon;Park, Hongsik;Kim, Kyu-Yong;Jeon, Jong-Up
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • An electromagnetic micro x-y stage for probe-based data storage (PDS) has been fabricated. The x-y stage consists of a silicon body inside which planar copper coils are embedded, a glass substrate bonded to the silicon body, and eight permanent magnets. The dimensions of flexures and copper coils were determined to yield $100{\;}\mu\textrm{m}$ in x and y directions under 50 mA of supplied current and to have 440 Hz of natural frequency. For the application to PDS devices, electromagnetic stage should have flat top surface for the prevention of its interference with multi-probe array, and have coils with low resistance for low power consumption. In order to satisfy these design criteria, conducting planar copper coils have been electroplated within silicon trenches which have high aspect ratio ($5{\;}\mu\textrm{m}$in width and $30{\;}\mu\textrm{m}$in depth). Silicon flexures with a height of $250{\;}\mu\textrm{m}$ were fabricated by using inductively coupled plasma reactive ion etching (ICP-RIE). The characteristics of a fabricated electromagnetic stage were measured by using laser doppler vibrometer (LDV) and dynamic signal analyzer (DSA). The DC gain was $0.16{\;}\mu\textrm{m}/mA$ and the maximum displacement was $42{\;}\mu\textrm{m}$ at a current of 180 mA. The measured natural frequency of the lowest mode was 325 Hz. Compared with the designed values, the lower natural frequency and DC gain of the fabricated device are due to the reverse-tapered ICP-RIE process and the incomplete assembly of the upper-sided permanent magnets for LDV measurements.

  • PDF

Design of Electromagnetically Driven Micro Scanning Mirror for Laser Animation System (레이저 디스플레이를 위한 전자력 구동 스캐닝 미러의 설계)

  • Lee, Kyoung-Gun;Jang, Yun-Ho;Yoo, Byung-Wook;Jin, Joo-Young;Lim, Yong-Geun;Kim, Yong-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.578-585
    • /
    • 2009
  • In this paper, we present the design of an electromagnetic scanning mirror with torsional springs. The scanning mirror consisting of torsional springs and electromagnetic coils was designed for the applications of laser animation systems. We analyzed and optimized three types of torsional springs, namely, straight beam springs (SBS), classic serpentine springs (CSS), and rotated serpentine springs (RSS). The torsional springs were analyzed in terms of electrical resistance, fabrication error tolerance, and resonance mode separation of each type using analytical formula or numerical analysis. The RSS has advantages over the others as follows: 1) A low resistance of conductors, 2) wide resonance mode separation, 3) strong fabrication error tolerance, 4) a small footprint. The double-layer coils were chosen instead of single-layer coils with respect to electromagnetic forces. It resulted in lower power consumption. The geometry of the scanning mirror was optimized by calculations; RSS turn was 12 and the width of double-layer coil was $100{\mu}m$, respectively. When the static rotational angle is 5 degrees, the power consumption of the mirror plate was calculated to be 9.35 mW since the resistance of the coil part and a current is $122{\Omega}$ and 8.75 mA, respectively. The power consumption of full device including the mirror plate and torsional springs was calculated to be 9.63 mW.

Analysis of Equivalent Circuit Approach for Ridge Type CPW Traveling - Wave Structure (릿지 형태 CPW 진행파형 구조의 등가회로 분석)

  • 윤상준;공순철;옥성해;윤영설;구민주;박상현;최영완
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.3
    • /
    • pp.45-54
    • /
    • 2004
  • Microwave characteristics of ridge type CPW traveling-wave(TW) electroabsorption modulator and photodetector are affected by the thickness of intrinsic layer, width of guiding layer, and the separation of signal and ground electrodes. These factors are determined effective index of microwave and characteristic impedance due to changing of capacitance(C) and inductance(L) of device. However, conventional equivalent circuit of TW-structure is approximated to microstrip and CPW transmission line by distribution of electric and magnetic fields, respectively. In this paper, we analyzed microwave characteristics of TW-structure and found more accurate value of C and L by using finite difference time domain (FDTD) method. These values are adopted circuit element of equivalent circuit. Microwave characteristics obtained by the FDTD and equivalent circuit model show good agreement.

Fabrication from the Hybrid Quantum Dots of CdTe/ZnO/G.O Quasi-core-shell-shell for the White LIght Emitting DIodes

  • Kim, Hong Hee;Lee, YeonJu;Lim, Keun yong;Park, CheolMin;Hwang, Do Kyung;Choi, Won Kook
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.189-189
    • /
    • 2016
  • Recently, many researchers have shown an increased interest in colloidal quantum dots (QDs) due to their unique physical and optical properties of size control for energy band gap, narrow emission with small full width at half maxima (FWHM), broad spectral photo response from ultraviolet to infrared, and flexible solution processing. QDs can be widely used in the field of optoelectronic and biological applications and, in particular, colloidal QDs based light emitting diodes (QDLEDs) have attracted considerable attention as an emerging technology for next generation displays and solid state lighting. A few methods have been proposed to fabricate white color QDLEDs. However, the fabrication of white color QDLEDs using single QD is very challenging. Recently, hybrid nanocomposites consisting of CdTe/ZnO heterostructures were reported by Zhimin Yuan et al.[1] Here, we demonstrate a novel but facile technique for the synthesis of CdTe/ZnO/G.O(graphene oxide) quasi-core-shell-shell quantum dots that are applied in the white color LED devices. Our best device achieves a maximum luminance of 484.2 cd/m2 and CIE coordinates (0.35, 0.28).

  • PDF

A Study on Design and Fabricate of a Intermediate Frequency Band SAW Filter (IF 대역 SAW 필터 설계 및 제작)

  • 유일현;권희두;정양희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • We have studied a method to design and fabricate the Intermediate Frequency(IF) band pass filter with low shape factor which is used for CDMA base station on the 35°Y-cut X-propagation Quartz substrate. In order to fabricate a device of the low shape factor for the IF SAW filter on this substrate, we employed apodization weighted type interdigital transducer(IDT) as an input and withdrawal weighted type IDT as an output by using impulse modelling method. Also, using the Kaiser-Bessel window function, we have adopted 2200pairs and 1000pairs of input and oueut IDT respectively to minimize the effect of ripple. Furthermore, the width and the space of IDT finger are 3.6 ㎛ and 3.5 ㎛ respectively. Thus, we can have optimal results when the IDT thickness is 6000Å in consideration of the ratio of SAW's wavelength while it's aperture is 2mm for impedance matching. The fabricated SAW filter for CDMA had the property of almost 115.2MHz of a center frequency, less then 1.27MHz of bandwidth, less than 1.3 of shape factor, - l5dB of out band attenuation insertion loss and -45dB of rejection band.

  • PDF

Fabrications and Properties of MFIS Structures using high Dielectric AIN Insulating Layers for Nonvolatile Ferroelectric Memory (고유전율 AIN 절연층을 사용한 비휘발성 강유전체 메모리용 MFIS 구조의 제작 및 특성)

  • Jeong, Sun-Won;Kim, Gwang-Hui;Gu, Gyeong-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.11
    • /
    • pp.765-770
    • /
    • 2001
  • Metal-ferroelectric-insulator- semiconductor(MFTS) devices by using rapid thermal annealed (RTA) LiNbO$_3$/AIN/Si(100) structures were successfully fabricated and demonstrated nonvolatile memory operations. Metal-insulator-semiconductor(MIS) C-V properties with high dielectric AIN thin films showed no hysteresis and good interface properties. The dielectric constant of the AIN film calculated from the capacitance at the accumulation region in the capacitance-voltage(C-V) characteristics was about 8. The C-V characteristics of MFIS capacitor showed a hysteresis loop due to the ferroelectric nature of the LiNbO$_3$ thin films. Typical dielectric constant value of LiNbO$_3$ film of MFIS device was about 23. The memory window width was about 1.2 V at the gate voltage of $\pm$5 V ranges. Typical gate leakage current density of the MFIS structure was the order of 10$^{-9}$ A/$\textrm{cm}^2$ at the range of within $\pm$500 kV/cm. The ferroelectric capacitors showed no polarization degradation up to about 10$^{11}$ switching cycles when subjected to symmetric bipolar voltage pulse(peak-to-peak 8 V, 50 % duty cycle) in the 500 kHz.

  • PDF

The effects of Breif, Intense Transecutaneous Electrical Nerve Stimulation on Nerve conduction, Pain Threshold in Healthy subjects (Brief, Intense TENS 자극이 신경전도, 통증역치의 변화에 미치는 효과)

  • Kim Tae-Youl;Hwang Tae-Yeun;Huh Choon-Bok
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.171-183
    • /
    • 1994
  • Purphose. This present study examines the effect of brief, intense transcutaneous electrical nerve stimulation(BTENS) on sensory nerve conduction, electrical pain threshold, and two-point discrimination measured at the superficial radial nevre distribution in 20 healthy subjects. Subjects. Twenty volunteercs, (10 females and 10 males(age range : 20-38 years : $mean{\pm}SD\;:\;27.00{\pm}5.12$), only subjects without prior traumatological and pathological were eligible to participated in this study. Methods. Nerve conduction were determined for the right superficial radial nerve. Electrical pain threshold were determined for the right wrist ipsilateral to the site of BTENS. Small disc electrodes were attached to the surface of the skin stradding the end of the radius. Square wave electrical pulses were delivered from an isolated stimulator through a constant current device at a frequency of 2 Hz(5 ms pulse width). Two-point discrimination, measured on the sensory distribution of superficial radial nerve. BTENS was delivered using a Max-SD( Medical design co.) portable battery powered stimulator. A cicular Ag/AgCl electrode in contact with hypertonic saline gel was attached to the lateral(radial side) surface of the forearm. Results. No significant effects were observed between stimulation methods in the prestimulation cycle(multi-way ANOVA repeated measures : distal latency ; F1.14=0.332. amplitude ; F 0.80=0.445, pain threshold ; F0.06=0.940.2 point discrimination ; F1.50=0.236). Highly significant effects were observed time with the pretreatment and 6 posttreatment cycles(p<0.01). Mighty significants differences in nerve conduction and pain threshold were found using un multi-way ANOVA repeated measures among stimulation methods for each cycles(p<0.01). Conclusion and Discussion The authors concludes that both nerve conduction and pain threshold changes are associated with therapy (stimulation) level of BTENS.

  • PDF

The Use of Pedicle Screw-Rod System for the Posterior Fixation in Cervico-Thoracic Junction

  • Cho, Won-ik;Eid, Ahmed Shawky;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • Objective : In cervico-thoracic junction (CTJ), the use of strong fixation device such as pedicle screw-rod system is often required. Purpose of this study is to analyze the anatomical features of C7 and T1 pedicles related to screw insertion and to evaluate the safety of pedicle screw insertion at these levels. Methods : Nineteen patients underwent posterior CTJ fixation with C7 and/or T1 included in fixation levels. Seventeen patients had tumorous conditions and two with post-laminectomy kyphosis. The anatomical features were analyzed for C7 and T1 pedicles in 19 patients using computerized tomography (CT). Pedicle screw and rod fixation system was used in 16 patients. Pedicle violation by screws was evaluated with postoperative CT scan. Results : The mean values of the width, height, stable depth, safety angle, transverse angle, and sagittal angle of C7 pedicles were $6.9{\pm}1.34\;mm$, $8.23{\pm}1.18\;mm$, $30.93{\pm}4.65\;mm$, $26.42{\pm}7.91$ degrees, $25.9{\pm}4.83$ degrees, and $10.6{\pm}3.39$ degrees. At T1 pedicles, anatomic parameters were similar to those of C7. The pedicle violation revealed that 64.1% showed grade I violation and 35.9% showed grade II violation, overall. As for C7 pedicle screw insertion, grade I was 61.5% and grade II 38.5%. At T1 level, grade I was 65.0% and grade II 35.0%. There was no significant difference in violation rate between the whole group, C7, and T1 group. Conclusion : C7 pedicles can withstand pedicle screw insertion. C7 pedicle and T1 pedicle are anatomically very similar. With the use of adequate fluoroscopic oblique view, pedicle screw can be safely inserted at C7 and T1 levels.