Browse > Article
http://dx.doi.org/10.3340/jkns.2010.48.1.46

The Use of Pedicle Screw-Rod System for the Posterior Fixation in Cervico-Thoracic Junction  

Cho, Won-ik (Department of Neurosurgery, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Science)
Eid, Ahmed Shawky (Department of Orthopedic Surgery, Ain Shams University)
Chang, Ung-Kyu (Department of Neurosurgery, Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Science)
Publication Information
Journal of Korean Neurosurgical Society / v.48, no.1, 2010 , pp. 46-52 More about this Journal
Abstract
Objective : In cervico-thoracic junction (CTJ), the use of strong fixation device such as pedicle screw-rod system is often required. Purpose of this study is to analyze the anatomical features of C7 and T1 pedicles related to screw insertion and to evaluate the safety of pedicle screw insertion at these levels. Methods : Nineteen patients underwent posterior CTJ fixation with C7 and/or T1 included in fixation levels. Seventeen patients had tumorous conditions and two with post-laminectomy kyphosis. The anatomical features were analyzed for C7 and T1 pedicles in 19 patients using computerized tomography (CT). Pedicle screw and rod fixation system was used in 16 patients. Pedicle violation by screws was evaluated with postoperative CT scan. Results : The mean values of the width, height, stable depth, safety angle, transverse angle, and sagittal angle of C7 pedicles were $6.9{\pm}1.34\;mm$, $8.23{\pm}1.18\;mm$, $30.93{\pm}4.65\;mm$, $26.42{\pm}7.91$ degrees, $25.9{\pm}4.83$ degrees, and $10.6{\pm}3.39$ degrees. At T1 pedicles, anatomic parameters were similar to those of C7. The pedicle violation revealed that 64.1% showed grade I violation and 35.9% showed grade II violation, overall. As for C7 pedicle screw insertion, grade I was 61.5% and grade II 38.5%. At T1 level, grade I was 65.0% and grade II 35.0%. There was no significant difference in violation rate between the whole group, C7, and T1 group. Conclusion : C7 pedicles can withstand pedicle screw insertion. C7 pedicle and T1 pedicle are anatomically very similar. With the use of adequate fluoroscopic oblique view, pedicle screw can be safely inserted at C7 and T1 levels.
Keywords
Pedicle screw; Cervico-thoracic junction; Posterior fixation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 0
연도 인용수 순위
1 Bueff HU, Lotz JC, Colliou OK, Khapchik V, Ashford F, Hu SS, et al. : Instrumentation of the cervicothoracic junction after destabilization. Spine (Phila Pa 1976) 20 : 1789-1792, 1995   DOI   ScienceOn
2 Choueka J, Spivak JM, Kummer FJ, Steger T : Flexion failure of posterior cervical lateral mass screws. Influence of insertion technique and position. Spine (Phila Pa 1976) 21 : 462-468, 1996   DOI   ScienceOn
3 Lee GY, Massicotte EM, Rampersaud YR : Clinical accuracy of cervicothoracic pedicle screw placement : a comparison of the "open" lamino-foraminotomy and computer-assisted techniques. J Spinal Disord Tech 20 : 25-32, 2007   DOI   ScienceOn
4 Reinhold M, Magerl F, Rieger M, Blauth M : Cervical pedicle screw placement : feasibility and accuracy of two new insertion techniques based on morphometric data. Eur Spine J 16 : 47-56, 2007   DOI   ScienceOn
5 Sapkas G, Papadakis S, Katonis P, Roidis N, Kontakis G : Operative treatment of unstable injuries of the cervicothoracic junction. Eur Spine J 8 : 279-283, 1999   DOI   ScienceOn
6 Jones EL, Heller JG, Silcox DH, Hutton WC : Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976) 22 : 977-982, 1997   DOI   ScienceOn
7 Ebraheim NA, Jabaly G, Xu R, Yeasting RA : Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine (Phila Pa 1976) 22 : 1553-1556; discussion 1557, 1997   DOI   ScienceOn
8 Hong JT, Yi JS, Kim JT, Ji C, Ryu KS, Park CK : Clinical and radiologic outcome of laminar screw at C2 and C7 for posterior instrumentation-review of 25 cases and comparison of C2 and C7 intralaminar screw fixation. Surg Neurol 2009 [Epub ahead of print]
9 Inoue A, Ikata T, Katoh S : Spinal deformity following surgery for spinal cord tumors and tumorous lesions : analysis based on an assessment of the spinal functional curve. Spinal Cord 34 : 536-542, 1996   DOI   ScienceOn
10 Graham AW, Swank ML, Kinard RE, Lowery GL, Dials BE : Posterior cervical arthrodesis and stabilization with a lateral mass plate. Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications. Spine (Phila Pa 1976) 21 : 323-328; discussion 329, 1996   DOI   ScienceOn
11 Ebraheim NA, Xu R, Knight T, Yeasting RA : Morphometric evaluation of lower cervical pedicle and its projection. Spine (Phila Pa 1976) 22 : 1-6, 1997   DOI   ScienceOn
12 Xu R, Ebraheim NA, Yeasting R, Wong F, Jackson WT : Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8 : 116-120, 1995
13 Barrey C, Cotton F, Jund J, Mertens P, Perrin G : Transpedicular screwing of the seventh cervical vertebra : anatomical considerations and surgical technique. Surg Radiol Anat 25 : 354-360, 2003   DOI   ScienceOn
14 Cha SH, Kim C, Choi BK, Kim HJ, Baek SY : C-arm assessment of cervical pedicle screw : screw coaxial fluoroscopy and oblique view. Spine (Phila Pa 1976) 32 : 1721-1727, 2007   DOI   ScienceOn
15 Chapman JR, Anderson PA, Pepin C, Toomey S, Newell DW, Grady MS : Posterior instrumentation of the unstable cervicothoracic spine. J Neurosurg 84 : 552-558, 1996   DOI   ScienceOn
16 An HS, Wise JJ, Xu R : Anatomy of the cervicothoracic junction : a study of cadaveric dissection, cryomicrotomy, and magnetic resonance imaging. J Spinal Disord 12 : 519-525, 1999
17 Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K : Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine (Phila Pa 1976) 25 : 962-969, 2000   DOI   ScienceOn
18 An HS, Vaccaro A, Cotler JM, Lin S : Spinal disorders at the cervicothoracic junction. Spine (Phila Pa 1976) 19 : 2557-2564, 1994   DOI   ScienceOn
19 Ugur HC, Attar A, Uz A, Tekdemir I, Egemen N, Caglar S, et al. : Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47 : 1162-1168; discussion 1168-1169, 2000   DOI   ScienceOn
20 Wang MY : Cervical crossing laminar screws : early clinical results and complications. Neurosurgery 61 : 311-315; discussion 315-316, 2007   DOI
21 Seo YJ, Song GS, Cho WH, Choi BK, Cha SH, Baek SY : Comparison of three different techniques in cervical transpedicular screw insertion. J Korean Neurosurg Soc 39 : 360-365, 2006   과학기술학회마을
22 Miller RM, Ebraheim NA, Xu R, Yeasting RA : Anatomic consideration of transpedicular screw placement in the cervical spine. An analysis of two approaches. Spine (Phila Pa 1976) 21 : 2317-2322, 1996   DOI   ScienceOn
23 Stulik J, Vyskocil T, Sebesta P, Kryl J, Pafko P : [Surgical treatment for disorders of the cervicothoracic junction region.] Acta Chir Orthop Traumatol Cech 72 : 213-220, 2005
24 Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ : Placement of pedicle screws in the human cadaveric cervical spine : comparative accuracy of three techniques. Spine (Phila Pa 1976) 25 : 1655-1667, 2000   DOI   ScienceOn
25 Mazel C, Hoffmann E, Antonietti P, Grunenwald D, Henry M, Williams J : Posterior cervicothoracic instrumentation in spine tumors. Spine (Phila Pa 1976) 29 : 1246-1253, 2004   DOI   ScienceOn
26 Kreshak JL, Kim DH, Lindsey DP, Kam AC, Panjabi MM, Yerby SA : Posterior stabilization at the cervicothoracic junction. A biomechanical study. Spine (Phila Pa 1976) 27 : 2763-2770, 2002   DOI   ScienceOn
27 Le H, Balabhadra R, Park J, Kim D : Surgical treatment of tumors involving the cervicothoracic junction. Neurosurg Focus 15 : E3, 2003
28 Ludwig SC, Kowalski JM, Edwards CC 2nd, Heller JG : Cervical pedicle screws : comparative accuracy of two insertion techniques. Spine (Phila Pa 1976) 25 : 2675-2681, 2000   DOI   ScienceOn
29 Karaikovic EE, Daubs MD, Madsen RW, Gaines RW Jr : Morphologic characteristics of human cervical pedicles. Spine (Phila Pa 1976) 22 : 493-500, 1997   DOI   ScienceOn
30 Kotani Y, Cunningham BW, Abumi K, McAfee PC : Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine. Spine (Phila Pa 1976) 19 : 2529-2539, 1994   DOI   ScienceOn
31 Jeanneret B, Magerl F, Ward EH, Ward JC : Posterior stabilization of the cervical spine with hook plates. Spine (Phila Pa 1976) 16 : S56-S63, 1991   DOI