• Title/Summary/Keyword: width of device

Search Result 716, Processing Time 0.028 seconds

Detection Characteristics of a Red Blood Cell Coupled with Micron Magnetic Beads by Using GMR-SV Device (GMR-SV 소자를 이용한 미크론 자성비드와 결합된 적혈구 검출 특성 연구)

  • Lee, Jae-Yeon;Kim, Moon-Jong;Lee, Sang-Suk;Rhee, Jin-Kyu
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.101-106
    • /
    • 2014
  • The glass/Ta(5.8 nm)/NiFe(5 nm)/Cu(2.3 nm)/NiFe(3 nm)/IrMn(12 nm)/Ta(5.8 nm) GMR-SV (giantmagneto-resistance-spin valve) multilayer structure films with a magnetoresistance ratio (MR) of 5.0 % and a magnetic sensitivity (MS) of 1.5%/Oe was deposited by dc magnetron sputtering method. Also, GMR-SV device having a width of $7{\mu}m{\sim}8{\mu}m$ similar to the diameter of RBC (red blood cell) was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ dropped upon the GMR-SV device having MR = 1.06% and MS = 0.3 %/Oe, there is observed the variation of about included of a resistance value of ${\Delta}R=0.4{\Omega}$ and ${\Delta}MR=0.15%$ around a external magnetic field of -0.6 Oe. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property of hemoglobin inside of RBC combined to magnetic beads.

Design of PWM-Based Photo Irradiation System for Acne Treatment (여드름 치료를 위한 PWM 기반 광 조사 시스템 설계)

  • Kim, Chang-Su;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.207-215
    • /
    • 2012
  • As one of photo dynamic therapies, the existing LED photo irradiation method with 635 nm continuous wave has most frequently been used for acne treatment, it suffered from a low energy efficiency and generation of a large amount of heat in tissues requiring improvement measures. In this thesis, a LED photo irradiation system for acne treatment has been designed using PWM(Pulse Width Modulation) mode to enhance the energy efficiency and prevent thermal destruction in tissues. System configuration consisting largely of timer module, PWM module, and photo transfer device has been designed with the use of 1 W LED at a wavelength of 660 nm for the photo transfer device to increase skin penetration depth for treatment of acne. Frequency and wave form generated by using PWM control was verified along with confirmation of output energy of 660 nm LED and surface temperatures of tissues, followed by evaluation of stable energy outputs and stability of tissues. The results indicated that whereas power loss was high and thermal destruction in tissues was exhibited when C.W mode was used to obtain the optical energy of 1 W LED at a wavelength of 660 nm for acne treatment, realization of PWM mode allowed lowering of power consumption for LED through pulse width modulation, and no occurrence of thermal destruction in tissues, suggesting that PWM mode is safer and more effective for treatment of acne than C.W mode.

A CASE REPORT OF COMPLICATIONS DURING MANDIBULAR TRANSVERSE SYMPHYSIS WIDENING (하악 이부 확장술 시 나타나는 합병증의 치험례)

  • Suh, Chung-Whan;Kang, Kyung-Hwa;Choi, Moon-Gi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.480-488
    • /
    • 2008
  • Orthodontists often treat cases which are difficult to treat with conventional orthodontics. In such cases, it could be treated with surgical procedures with the help of an oral surgeon. Especially, transverse deficiency of the mandible can be corrected by widening the transverse width of mandibular symphysis, using distraction osteogenesis. Transverse widening of mandibular sympysis is known as a safe treatment but still complications could occur during the treatment. We are reporting some complications of cases that mandibular symphysis transverse widening were applied. Some cases showed complications because of the inappropriate osteotomy line. Since straight vertical osteotomy line was inclined to the left, only the left bony segment was likely to expand. According to bio-mechanical considerations, it will be better to perform a step osteotomy, cutting the eccentric area of the alveolar crest and the centric area of the basal symphyseal area. Complications could also occur by the failure of the distraction device. The tooth borne distraction device was attached on the lingual side of the tooth with composite resin. During the distraction period, it was impossible to obtain appropriate distraction speed and rhythm because of frequent fall off of the distraction device. Therefore, distraction device should be attached firmly with orthodontic band or bone screw, etc. Tooth mobility increasement could also occur as a complication. 'Walking teeth phenomenon' was observed during the distraction period, showing severe teeth mobility and pain during mastication. These symptoms fade out during the consolidation period. Since the patient could feel insecure and uncomfortable, it should be notified to the patient before the procedure. Finally, alveolar crestal bone loss could occur. Alveolar crestal bone loss occurred because of lack of distraction device firmness and teeth trauma caused by lower lip biting habit. Therefore, adequate firmness of the distraction device and habit control will be needed.

Fabrication of Nano-filter Device for High Efficient Separation and Concentration of Biomolecules (고효율 바이오물질 분리 및 농축을 위한 나노필터소자제작)

  • Huh, Yun Suk;Choi, Bong Gill;Hong, Won Hi
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.738-742
    • /
    • 2012
  • Here, we develop a new nanofilter device for the rapid and efficient separation of nanoparticles and biomolecules, exploiting the use of AAO mebrane with ordered nanopores in the range from 20 nm to 200 nm. Briefly, the chip comprises of a series of the upper and lower PDMS channels containing embedded inlet and outlet ports, and $50{\mu}m$ width microfluidic channel, and AAO membrane to be made the filtering zone. After assembling these components, the acrylate plastic plates were used to fix the device on the top and bottom side. When introducing the samples into the inlet ports of the upper PDMS channel, we were able to separate and concentrate the nanoparticles and target molecules at the filtering zone, and to elute the solutions containing the unwanted materials toward the lower PDMS channels normal to the direction of AAO membrane. To demonstrate the usefulness of the device we apply it to the SERS detection of nucleic acid sequences associated with Dengue virus serotype 2. We report a limit of detection for Dengue sequences of 300 nM and show excellent enhancement of Raman signals from the filter zone of the nanofilter device.

Detection Property of Red Blood Cell-Magnetic Beads Using Micro Coil-Channeland GMR-SV Device (마이크로 코일-채널과 GMR-SV 소자를 이용한 적혈구-자성비드 검출 특성연구)

  • Park, Ji-Soo;Kim, Nu-Ri;Jung, Hyun-Jun;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2015
  • The micro device, coil, and channel for the biosensor integrated with the GMR-SV device based on the antiferromagnetic IrMn layer was fabricated by the light lithography process. When RBCs coupled with several magnetic beads with a diameter of $1{\mu}m$ passed on the micro channel, the movement of $RBC+{\mu}Beads$ is controlled by the electrical AC input signal. The $RBC+{\mu}Beads$ having a micro-magnetic field captured above the GMR-SV device is changed as the output signals for detection status. From these results, the GMR-SV device having the width magnitude of a few micron size can be applied as the biosensor for the analysis of a new magnetic property as the membrane's deformation of RBC coupled to magnetic beads.

Impact of Fin Aspect Ratio on Short-Channel Control and Drivability of Multiple-Gate SOI MOSFET's

  • Omura, Yasuhisa;Konishi, Hideki;Yoshimoto, Kazuhisa
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.4
    • /
    • pp.302-310
    • /
    • 2008
  • This paper puts forward an advanced consideration on the design of scaled multiple-gate FET (MuGFET); the aspect ratio ($R_{h/w}$) of the fin height (h) to fin width (w) of MuGFET is considered with the aid of 3-D device simulations. Since any change in the aspect ratio must consider the trade-off between drivability and short-channel effects, it is shown that optimization of the aspect ratio is essential in designing MuGFET's. It is clearly seen that the triple-gate (TG) FET is superior to the conventional FinFET from the viewpoints of drivability and short-channel effects as was to be expected. It can be concluded that the guideline of w < L/3, where L is the channel length, is essential to suppress the short-channel effects of TG-FET.

Fabrication and Measurement of 4H-SiC MESFET for High Friquency Applications (고주파용 4H-SiC MESFET 제작 및 측정)

  • Kim, Jae-Kwon;Song, Nam-Jin;Kim, Tae-Woon;Burm, Jin-Wook;An, Chul
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.33-36
    • /
    • 2002
  • MESFET was fabricated using 4H-SiC substrates and epitaxy The DC characteristics of 0.5 urn gate length, 400 urn gate width MESFET had $I_{dss}$=200 ㎃/mm, maximum transconductance of 12 ㎳/mm at Vrs=-4 V, V, Is=27 V. Thc device had an fT of 2.5 GHz and $f_{mdx}$ of 13.3 GHz at $V_{ds}$ =27 V and $V_{g}$=-4 V. The fabrication and characterization of this device are discussed.d.d.d.

  • PDF

A Novel Wavelength Sensor Using A Structure Of Optical Directional Coupler

  • Sae-Tang, K.;Somkuarnpanit, S.;Khuntaweetep, S.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.542-544
    • /
    • 2002
  • This paper proposes a wavelength sensor based on the optical directional coupler. The finite-difference time-domain (FDTD) is used in analysis of the field intensity of tile light propagating thorough the structure. The device with tile width of 0.4 $\mu\textrm{m}$ and the thickness of 0.4 $\mu\textrm{m}$, which corresponding with the coupling length of 40$\mu\textrm{m}$, would provide tile linear relationship between the coupling efficiency against the wavelength. The device can sense the wavelength in a range between 1.5$\mu\textrm{m}$ and 1.6$\mu\textrm{m}$, with continuous resolution. The wide wavelength could be also done be paralleling th light to a number of wavelength-sensing modules with particularly required bands. Therefore, it could be employed as the wavelength sensing for most optical communications, optoelectronics, laser applications and etc.

  • PDF

Optical System with 4 ㎛ Resolution for Maskless Lithography Using Digital Micromirror Device

  • Lee, Dong-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.266-276
    • /
    • 2010
  • In the present study, an optical system is proposed for maskless lithography using a digital micromirror device (DMD). The system consists of an illumination optical system, a DMD, and a projection lens system. The illumination optical system, developed for 95% uniformity, is composed of fly's eye lens plates, a 405 nm narrow band pass filter (NBPF), condensing lenses, a field lens and a 250W halogen lamp. The projection lens system, composed of 8 optical elements, is developed for 4 ${\mu}m$ resolution. The proposed system plays a role of an optical engine for PCB and/or FPD maskless lithography. Furthermore, many problems arising from the presence of masks in a conventional lithography system, such as expense and time in fabricating the masks, contamination by masks, disposal of masks, and the alignment of masks, may be solved by the proposed system. The proposed system is verified by lithography experiments which produce a line pattern with the resolution of 4 ${\mu}m$ line width.

Design of DGMOSFET for Optimum Subthreshold Characteristics using MicroTec

  • Jung, Hak-Kee;Han, Ji-Hyeong
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.449-452
    • /
    • 2010
  • We have analyzed channel doping and dimensions(channel length, width and thickness) for the optimum subthreshold characteristics of DG(Double Gate) MOSFET based on the model of MicroTec 4.0. Since the DGMOSFET is the candidate device to shrink short channel effects, the determination of design rule for DGMOSFET is very important to develop sub-100nm devices for high speed and low power consumption. As device size scaled down, the controllability of dimensions and oxide thickness is very low. We have analyzed the short channel effects for the variation of channel dimensions, and found the design conditions of DGMOSFET having the optimum subthreshold characteristics for digital applications.