• Title/Summary/Keyword: wide connection

Search Result 334, Processing Time 0.023 seconds

The Performance Evaluation and the Optimal Design of 2MW DFIG (2MW급 DFIG 최적 설계 및 성능 평가에 관한 연구)

  • Cho, Sung-Ho;Oh, Young-Jin;Moon, Byeong-Sun;Lee, Seung-Kuh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.382-385
    • /
    • 2007
  • The optimal design and characteristic analysis of Double Fed Induction Generator(DFIG) was performed. The purpose of the paper is to verify the accuracy of design and the reliability of DFIG by experiment. A grid connection experiment is performed to confirm generating performance in wide operating range. In this experiment, 2.7MW M/G set is used. The finite element method is applied to calculate parameters and characteristic analysis of DFIG. And in order to reduce design time and efforts, Design of Experiment(DOE) is used. The experimental results are compared with the optimum design results.

  • PDF

HIGH-ENERGY SOLAR PARTICLE EVENTS IN THREE DIMENSIONS

  • Kocharov, Leon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.45.1-45.1
    • /
    • 2010
  • Using SOHO particle and EUV detection and radio spectrograms from both ground-based and spaceborne instruments, we have studied the first phase of major solar energetic particle (SEP) events associated with wide and fast coronal mass ejections (CMEs) centered at different solar longitudes. Observations support the idea that acceleration of SEPs starts in the helium-rich plasma of the eruption's core well behind the CME leading edge, in association with coronal shocks and magnetic reconnection caused by the CME liftoff; and those "coronal" components dominate during the first ~1.5 hour of the SEP event, not yet being hidden by the CME-bow shock in solar wind. At magnetic connection to the eruption's periphery, onset of SEP emission is delayed for a time of the lateral expansion that is visualized by global coronal (EIT) wave. The first, "coronal" phase of SEP acceleration is followed by a second phase associated with CME-driven shock wave in solar wind, which accelerates high-energy ions from a helium-poor particle population until the interplanetary shock slows down to below 1000 km/s. Based on these and other SOHO observations, we discuss what findings can be expected from STEREO in the SOHO era perspective.

  • PDF

A Study on the New Widely Tunable Optical Filter for Ring Laser (링 레이저를 위한 새로운 광대역 파장 가변 필터에 대한 연구)

  • Kim, Kwang-Yoo;Lee, Jung-Ryul;Eom, Jin-Seob
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.95-99
    • /
    • 2006
  • In this paper, we proposed the new wavelength tunable filter for wide tunability of fiber ring laser. The proposed filter consists of the cascaded connection of Fiber Reflection Mach-Zehnder Interferometer and Sagnac filter or of hybrid filter and Fiber Reflection Mach-Zehnder Interferometer. The simulation shows that the continuous tunable range of 50nm can be obtained and that more stable single mode operation of ring laser can be expected due to narrow FWHM. of filter spectrum.

  • PDF

QUASI-RESONANT ZVS-PWM DC-DC FORWARD CONVERTER WITH ACTIVE CLAMPED CAPACITOR FOR SOLAR PHOTOVOLTAIC ENERGY-DRIVEN BOAT SYSTEM

  • Kenya, Sakamoto;Masakazu, Kanaoka;Hidekazu, Muraoka;Ryuhei, Hojyo;Mutsuo, Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.68-73
    • /
    • 1998
  • This paper presents a novel prototype of active voltage clamped quasi-resonant ZVS-PWM forward DC-DC converter designed for specific low voltage high current application. We establish the soft-switching forward converter with a high frequency isolated link which can efficient operate over wide load ranges under conditions of zero voltage soft-switching and active voltage clamped switching. In addition, we evaluate connection of the soft-switching forward converter with large capacitor which capacitance is over 100[F].

  • PDF

Construction Safety Management Framework based on Smart Mobile

  • Park, Moon-Seo;Kim, Eui-Jun;Lee, Hyoo-Soo;Lee, Kwang-Pyo
    • Journal of Construction Engineering and Project Management
    • /
    • v.2 no.3
    • /
    • pp.48-57
    • /
    • 2012
  • With increasing number of serious construction disasters such as death, a safety management in real-time is more required recently. One of the ways to support the needs, a convergence with Information Technology (IT) has been noticed. Although number of inefficiencies including a limitation of IT equipment (weight, control inconveniences) has been concerned, data exchanging and processing fields have been improved at a wide range with an advance of mobile communication and an introduction of smart mobiles that are simple and convenient. In this research, a framework is realized in connection with smart mobile to find the problems of current safety management and derive demands in order to support effective safety management. Two smart mobile applications, Safety Management application and Safety Guideline application, enable a real-time safety management and less re-work by provided safety information.

The Development of AC Motor Control System Using DIP-IPM (DIP-IPM을 이용한 전동기 제어시스템 개발)

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Kim, Dong-Hee;Choi, Ho-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.232-234
    • /
    • 2002
  • Due to development of power electronics technology, power conversion system are tend to small size, easy to use and light weight. Especially motor control system have increased concerns and interests about IPM(Intelligent Power Module) inverter, which contains protection circuit, drive circuit and power devices. So, we manufactured 3-phase inverter using DIP-IPM(Dual in-line package IPM) PS21245- E(1.5 Kw) made by MITSUBISHI Electric. Some of these features include -HVIC to Provide level shifting and gate drive for high-side IGBTs. The interface circuit between pwm controller and DIP-IPM can made by direct connection. In order to validate dynamic performance of the proposed system, the actual experiment worked out at wide speed range. The developed system is shown as a good dynamic characteristics.

  • PDF

A Study on the Congestion Control with Multiple Time Scale under Self-Similar Traffic (자기유사성 트래픽 조건에서 다중 시간 간격을 이용한 혼잡제어에 관한 연구)

  • Cho, Hyeon-Seob;Kim, Young-Cho;Kim, Hui-Suk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.294-297
    • /
    • 2006
  • Measurement of network traffic have shown that the self-similarity is a ubiquitous phenomenon spanning across diverse network environments. In previous work, we have explored the feasibility of exploiting the long-range correlation structure in a self-similar traffic for the congestion control. we show that a multiple time scale TCP endows the underlying feedback control with proactivity by bridging the uncertainty gap associated with reactive controls which is exacerbated by the high delay-bandwidth product in broadband wide area networks. Third, we investigate the influence of the three traffic control dimensions-tracking ability, connection duration, and fairness-on performance.

  • PDF

Analysis and Comparision of Measured and Calculated Value on Magnetic Fields Strength under Transmission Lines (초고압 송전선로의 자계크기 해석과 실측 비교)

  • Cho, Sung-Bae;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.832-838
    • /
    • 1999
  • Recently, there are growing concerns about power frequency electric and magnetic fields coming out from the high voltage transmission lines, because of the wide spread perception of their probable harmful effect on human body. In connection with this trend, this paper describes the electric and magnetic fields measurement result around 154 kV and 345 kV transmission lines, a comparison of measured EMF to calculated one and the correlations between transmission lines currents and measured magnetic fields. Daily maximum and minimum magnetic field quantities under the selected 154 kV and 345 kV transmission lines had been measured for 1 year of 1997 and the average value of magnetic field exposure under the lines were calculated and presented based on the measured data.

  • PDF

Design and Application of Electric Field Sensor for Measuring PD Signals in High Voltage Equipments (고전압설비에서 발생하는 부분방전 검출용 전계센서의 설계 및 특성 검토)

  • 이강원;강성화;임기조
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.431-435
    • /
    • 2003
  • It is very difficult and dangerous to measure PD(Partial Discharges) from high voltage equipments in outdoor situation. But that is very important thing for preventing them from more serious accident by defects made by insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor can detect PD signals without direct connection between sensor and high voltage equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal show good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulses.

A Study on Active Voltage Control of Series Connected IGBTs (IGBT소자 직렬연결 구동 연구)

  • Hong, S.W.;Yang, H.J.;Kim, J.M.;Lee, H.S.;Chang, B.H.;Oh, K.I.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1966-1968
    • /
    • 1998
  • This paper describes a gate drive circuit for series connected IGBTs in high voltage applications. The proposed control criterion of the gate circuit is to actively limit the voltages during switching transients, while minimizing switching transient and losses. In order to achieve the control criterion, an analog closed loop control scheme is adopted. The performance of gate drive circuit is examined experimentally by the series connection of three IGBTs with conventional snubber circuits. The experimental results show the voltage balancing by an active control under wide variation in loads and imbalance conditions.

  • PDF