• 제목/요약/키워드: welded reinforcing bars

검색결과 11건 처리시간 0.024초

용접철망 콘크리트 벽체의 전단거동 연구 (Inplane Shear Behavior of Concrete Walls Reinforced by Welded Wire Fabric)

  • 김우;정란;양지수;윤영호;김대중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.130-135
    • /
    • 1993
  • Twelve 1/2 scale modeled wall specimens were tested statically up to failure to investigate she shear behavior of concrete walls reinforced with welded wire fabric. major variables were spacing of reinforcing bars, type of reinforcing bar(rebar, welded sire fabric, knurling wire) and the existence of tied column type reinforcement

  • PDF

Residual strength capacity of fire-exposed circular concrete-filled steel tube stub columns

  • Alhatmey, Ihssan A.;Ekmekyapar, Talha;Alrebeh, Salih K.
    • Advances in concrete construction
    • /
    • 제6권5호
    • /
    • pp.485-507
    • /
    • 2018
  • Concrete-Filled Steel Tube (CFST) columns are an increasingly popular means to support great compressive loads in buildings. The residual strength capacity of CFST stub columns may be utilized to assess the potential damage caused by fire and calculate the structural fire protection for least post-fire repair. Ten specimens under room conditions and 10 specimens under fire exposure to the Eurocode smouldering slow-growth fire were tested to examine the effects of diameter to thickness D/t ratio and reinforcing bars on residual strength capacity, ductility and stiffness of CFST stub columns. On the other hand, in sixteen among the twenty specimens, three or six reinforcing bars were welded inside the steel tube. The longitudinal strains in the steel tube and load-displacement relationships were recorded throughout the subsequent compressive tests. Corresponding values of residual strength capacity calculated using AISC 360-10 and EC4 standards are presented for comparison purposes with the experimental results of this study. The test results showed that after exposure to $750^{\circ}C$, the residual strength capacity increased for all specimens, while the ductility and stiffness were slightly decreased. The comparison results showed that the predicted residual strength using EC4 were close to those obtained experimentally in this research.

BIM 기반 프리패브 부재의 용접철근매트 정보교환 시스템 (BIM based Data Exchange System of Welded Wire/bar Mat for Pre-fab RC Members)

  • 정재환;김도형;김현기
    • 한국BIM학회 논문집
    • /
    • 제11권1호
    • /
    • pp.21-30
    • /
    • 2021
  • Reinforcing bars, a major component of the pre-fab structure, adheres to the existing on-site assembly method and attempts to develop and commercialize the technology of the pre-assembly method, but the effect is insignificant. Welded Wire / Bar Mat (WBM) has various advantages such as commercialization of rebar through machine manufacturing to improve workability, but it is different from the existing design and the construction method is different from the previous one. Therefore, to maximize the advantages of WBM and improve productivity, manufacturing, transportation, and construction from the design stage should be considered based on BIM from the initial design stage. In this paper, the concept of the design support system for the WBM was established based on the use of BIM in concrete reinforcement and the preliminary research on the WBM. WBM conversion design was performed for the existing prefabricated members, and based on this, the exchange format and system of the master prefabricated model with the WBM design data were set up. As a result of the pilot test, it was found that the traditional reinforcing bar information extracted from the master prefab model has transmitted 100% accurately. As for the WBM information, 100% of the information on the straight reinforcement was transmitted and represented, and the information on the bent reinforcement was found to have a 90% recall in the master BIM tool.

An experimental study of the behaviour of double sided welded plate connections in precast concrete frames

  • Gorgun, Halil
    • Steel and Composite Structures
    • /
    • 제29권1호
    • /
    • pp.1-22
    • /
    • 2018
  • Multi-storey precast concrete skeletal structures are assembled from individual prefabricated components which are erected on-site using various types of connections. In the current design of these structures, beam-to-column connections are assumed to be pin jointed. Welded plate beam to-column connections have been used in the precast concrete industry for many years. They have many advantages over other jointing methods in component production, quality control, transportation and assembly. However, there is at present limited information concerning their detailed structural behaviour under bending and shear loadings. The experimental work has involved the determination of moment-rotation relationships for semi-rigid precast concrete connections in full scale connection tests. The study reported in this paper was undertaken to clarify the behaviour of such connections under symmetrical vertical loadings. A series of full-scale tests was performed on sample column for which the column geometry and weld arrangements conformed with successful commercial practice. Proprietary hollow core slabs were tied to the beams by tensile reinforcing bars, which also provide the in-plane continuity across the connections. The strength of the connections in the double sided tests was at least 0.84 times the predicted moment of resistance of the composite beam and slab. The secant stiffness of the connections ranged from 0.7 to 3.9 times the flexural stiffness of the attached beam. When the connections were tested without the floor slabs and tie steel, the reduced strength and stiffness were approximately a third and half respectively. This remarkable contribution of the floor strength and stiffness to the flexural capacity of the joint is currently neglected in the design process for precast concrete frames. In general, the double sided connections were found to be more suited to a semi-rigid design approach than the single sided ones. The behaviour of double sided welded plate connection test results are presented in this paper. The behaviour of single sided welded plate connection test results is the subject of another paper.

강관구속 고강도 철근콘크리트 기둥의 내진성능 (Seismic Performance of High-Stringth RC Short Columns Confined in Rectangular Steel Tube)

  • 한병찬
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.182-190
    • /
    • 1997
  • A new method to prevent reinforced concrete columns from brittle failure. The method is called transversely reinforcing method in which only the critical regions are confined in steel tube. The steel tubes can change the failure mode of the latter columns from the shear to the flexure. The steel tubes also increase the compressive strength, shear strength and deformation capacity of the infilled concrete. The following conclusions are reached on bases of the study on the seismic performance of the high-strength RC rectangualr short columns confined in steel tube with shear span tho depth ratio of 2.0 The brittle shear failure of high-strength reinforced concrete short columns with large amount of longitudinal bars, which cannot prevented by using the maximum amount of welded hoops, can be prevented by using the steel tube which confines all the maximum amount of welded hoops, can be prevented by using the steel tube which confines all the concrete inclusive of cover concrete. High-strength RC short columns confined in rectangular steel tube provided excellent enhancement of seismic performance but, found that plastic buckling of the steel tube in the hinge regions tended to occur when the columns were subjected to large cyclic lateral displacements. In order to prevent the plastic buckling when the columns lies on large on cyclic lateral displacements, the steel ribs were used for columns. Tests have established that the columns provide excellent enhancement of seismic performance of inadequately confined columns.

  • PDF

복합모멘트접합을 갖는 콘크리트 충전 보-기둥 합성접합부의 반복하중 실험 (Cyclic Loading Tests of Concrete-Filled Composite Beam-Column Connections with Hybrid Moment Connections)

  • 임종진;김동관;이상현;이창남;엄태성
    • 한국강구조학회 논문집
    • /
    • 제28권5호
    • /
    • pp.345-354
    • /
    • 2016
  • 최근 합성 보-기둥 접합부를 위한 복합모멘트접합(hybrid moment connection)상세가 개발되었다. 기둥으로 팔각형태의 콘크리트 충전강관이 사용되었고, 보에는 U단면 콘크리트 충전강관이 사용되었다. 보-기둥 모멘트접합을 위해 보 강관은 기둥 강판에 직접 용접되었다. 하지만 보 하부 플랜지는 응력집중을 피하기 위하여 기둥 강판에 용접되지 않았고, 대신 보 플랜지의 인장력을 전달하기 위해 기둥 관통철근이 사용되었다. 기존 외다이어프램 보강상세 및 복합모멘트접합 상세를 갖는 총 4개의 실험체를 제작하고, 반복하중실험을 수행하였다. 실험결과 복합모멘트접합 상세는 보 플랜지의 인장력이 기둥 내부로 효과적으로 전달되었다. 또한, 하중재하능력 및 변형능력이 기존 외다이어프램 상세와 거의 동일한 수준으로 나타났다. 하지만, 최종 접합부 파괴모드는 복합모멘트접합 상세에 따라 영향을 받았다.

Up-Set Coupler 이음철근의 인장특성에 대한 실험적 연구 (An Experimental Study of Tension Properties on New Developed Up-Set Coupler)

  • 심종성;박철우;강태성;김태수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.109-115
    • /
    • 2008
  • 구조물이 초고층화, 대형화 되어감에 따라 철근의 이음방법에 대한 필요성이 증대되고 있다. 현재 일반적으로 건설현장에서는 겹이음을 많이 사용하고 있으나 굵은 직경을 사용한 구조부재의 경우 겹이음 사용 시 피복두께 확보의 어려움으로 부착파괴 및 접합부의 복잡한 배근으로 인한 콘크리트 타설의 시공성 저하 등이 문제가 되고 있다. 또한 압접이음은 철근의 단부를 국부적으로 가열하여 접합하는 방식으로 압접 후 철근의 취약부분이 발생할 수 있으므로 시공현장에서의 철저한 품질관리가 요구되는 단점이 있다. 이러한 단점을 해결하고자 새로운 개념의 Up-set Coupler를 적용하였다. 본 연구에서는 기계적 이음방법 중 철근 선조립공법이나 고강도, 대직경의 철근을 사용하는 PSC구조물의 접합부에서 주로 사용되는 대표적인 이음방법인 Screw Coupler와 Up-set Coupler, 그리고 이음이 없는 철근을 사용하여 각각의 인장특성과 사용성을 실험적으로 연구하고자 한다.

강-콘크리트 합성 바닥판용 전단연결재의 합성 거동 연구 (Composite Behavior of Perfobond Rib Shear Connector for Steel-concrete Decks)

  • 김형열;구현본
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.91-97
    • /
    • 2006
  • 본 연구에서는 강-콘크리트 합성 바닥판용 유공판재형 전단연결재의 전단성능을 평가하기 위한 전단실험을 수행하고 그 실험결과를 고찰하였다. 전단 실험체는 절곡된 강판, 유공판재형 전단연결재, 철근, 콘크리트로 구성되었으며, 절곡된 강판과 콘크리트 사이에 작용하는 수평전단력에 저항할 수 있도록 다수의 구멍이 가공된 유공판재형 전단연결재가 적용되었다. 실험체설계에 적용된 변수는 구멍의 간격과 위치, 구멍관통 철근의 유무이며, 총 12개의 실험체를 제작하여 전단실험을 수행하였다. 제한적 범위 내에서 수행한 실험결과에 따르면 유공판재형 전단연결재가 강-콘크리트 합성 바닥판에 효과적으로 사용될 수 있을 것으로 판단된다.

Behavior of simple precast high-strength concrete beams connected in the maximum bending moment zone using steel extended endplate connections

  • Magdy I. Salama;Jong Wan Hu;Ahmed Almaadawy;Ahmed Hamoda;Basem O. Rageh;Galal Elsamak
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.627-641
    • /
    • 2024
  • This paper presents an experimental and numerical study to investigate the behavior of the precast segmental concrete beams (PSCBs) utilizing high-strength concrete (HSC) connected in the zone of the maximum bending moment using steel extended endplate connections (EECs). The experimental study consisted of five beams as follows: The first beam was the control beam for comparison, which was an unconnected one-piece beam made of HSC. The other four other beams consisted of two identical pieces of precast concrete. An important point to be noted is that at the end of each piece, a steel plate was used with a thickness of 10 mm. Moreover, this steel plate was welded to the lower and upper reinforcing bars of the beam. Furthermore, the steel plate was made to connect the two pieces using the technique of EECs. Several variables were taken in these four beams, whether from the shape of the connection or enhancing the behavior of the connection using the post-tensioning technique. EECs without stiffeners were used for some of the tested beams. The behavior of these connections was improved using stiffeners and shear bolts. To get accurate results, a comparison was made between the behaviors of the five beams. Another important point to be noted is that Abaqus and SAP2000 programs were used to investigate the behavior of PSCBs and to ensure the accuracy of the modeling process which showed a good agreement with the experimental results. Additionally, the simplified modeling using SAP2000 was able to model the nonlinear behavior of PSCBs connected using steel EECs. It was found that the steel pre-tensioned bolted EECs, reinforced with steel stiffeners and shear anchors, could be used to connect the precast HSC segmental beams via the internal pre-stressing technique.

앵글과 철근을 조립한 PSRC 합성기둥의 휨 실험 (Flexural Test for Prefabricated Composite Columns Using Steel Angle and Reinforcing Bar)

  • 엄태성;황현종;박홍근;이창남;김형섭
    • 한국강구조학회 논문집
    • /
    • 제24권5호
    • /
    • pp.535-547
    • /
    • 2012
  • PSRC 기둥은 앵글을 콘크리트에 매입시킨 기둥으로, 단면의 외곽 코너에 배치되는 앵글이 기둥의 휨-압축에 저항하고, 횡철근은 기둥의 전단과 앵글-콘크리트 사이의 부착에 저항한다. 본 연구에서는 KBC 2009에 따라 PSRC 합성기둥의 휨, 전단, 부착 설계방법을 정립하고, 단순지지된 2/3 스케일의 PSRC 보와 SRC 보의 2점 가력 휨실험을 통하여 제안된 설계법을 검증하고 PSRC 합성기둥의 파괴특성을 분석하였다. 단면의 강재비와 횡철근 간격을 실험 변수로 고려하였다. 실험결과, KBC 2009으로 예측한 PSRC 합성기둥의 휨, 전단, 부착 강도는 실험결과와 잘 일치하였다. 고강도 앵글이 기둥 단면의 외곽에 배치되므로 PSRC 합성기둥은 동일한 강재비를 갖는 일반 SRC 합성기둥 단면에 비하여 매우 우수한 휨저항 성능을 나타냈다. 그러나 앵글과 콘크리트 사이의 부착강도가 충분히 학보되지 못한 경우 합성기둥 단면의 휨항복강도를 발휘하기 이전에 앵글의 부착파괴, 피복콘크리트 파괴, 횡철근의 파단 등이 발생하였다. 또한 앵글 용접성 및 인성이 부족할 경우 앵글-횡철근 용접부에서 앵글의 파단에 의해 실험체가 파괴되었다.