• Title/Summary/Keyword: water temperature hysteresis

Search Result 35, Processing Time 0.013 seconds

Correlation and Hysteresis Analysis of Air-Water Temperature in Four Rivers: Preliminary study for water temperature prediction (우리나라 하천의 기온-수온의 상관관계 및 이력현상 분석: 미래 하천수온 변화 예측을 위한 사전검토)

  • An, Ji-Hyuck;Lee, Khil-Ha
    • Journal of Environmental Policy
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2013
  • The potential impact of water temperature on air temperature in response to recent anthropogenic global warming has been noticed. To predict climate, induced change in river aquatic environment, it is necessary to understand the thermal constrains of fish species and the timing of the projected river temperature. As a preliminary study, air-water temperature relationship was analyzed on the basis of the observed data during the time period of 2009-2011 and the number of data corresponds to 873-1083. As a result of analyzing the auto-and cross-correlation coefficient between air-water temperature, high correlation is shown (~0.9). It is also found that the correlation coefficient of air temperature is higher than that of water temperature at the lag time less than approximately 10 days. Observed data was divided into two groups to investigate hysteresis: rising limb and falling limb. For some stations there is strong evidence that hysteresis exist between air-water temperature relationships. Consequently it is recommended that seasonal hysteresis needs to be included in determining an airwater relationship.

  • PDF

Effect of Air Temperature Changes on Water Temperature and Hysteresis Phenomenon in Lake Paldang (기온 변화에 따른 팔당호 수온 영향 및 이력현상)

  • Yu, Soonju;Im, Jongkwon;Lee, Bomi
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.5
    • /
    • pp.323-337
    • /
    • 2020
  • Long-term continuous data were used to investigate changes in air and water temperature and temperature hysteresis at Lake Paldang, the largest source of drinking water in South Korea. Based on the temperatures at Yangpyeong, near Lake Paldang, using a seasonal Mann-Kendall test, the rate of change of increase in temperature over the last 27 years (0.060℃/yr, 1993-2019) was higher than that of during 47 years (0.048℃/yr, 1973-2019). The air and water temperatures in Lake Paldang and its influent rivers had a high correlation (R > 0.9, p < 0.005); however, the water temperature increased at rate slower than the river water temperature, and the water temperature decreased slowly as the air temperature fell. The depth-averaged water temperature also changed more slowly than the surface water of the lake both when the air temperature was high and when it was low. This is likely because the lake has a larger area and a longer heat retention time than rivers, resulting in a greater hysteresis of water temperature at lake.

Hysteresis on Boiling Heat Transfer at Low Temperature on Enhanced Tubes in a Flooded Evaporator (만액식 증발기의 열전달 촉진관에서 저온 비등열전달의 이력현상 특성)

  • 윤현필;박종익;정진희;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.254-260
    • /
    • 2003
  • The boiling characteristics for R134a are studied to clarify the hysteresis at low temperature on enhanced tubes of a flooded evaporator. Initial boiling conditions, refrigerant temperature, and inlet temperature of the chilled water are considered as the key parameters of the experiments. Unlike previous studies of the boiling heat transfer with uniform heat flux and uniform wall temperature, the wall temperature was varied along the tube. In, this study, it was found that the hysteresis of the temperature overshoot (705) at the onset of nucleate boiling initially at the inlet section of the tube. It is also concluded that the abnormal operation can be avoided during the low temperature boiling if the refrigeration system is started with LMTD larger than $3.4^{\circ}C$ at initial stage and larger than $1.0^{\circ}C$ at normal stage.

Correlation and Hysteresis Analysis between Air and Water Temperatures in the Coastal Zone - Masan Bay (연안해역 기온과 수온의 상관관계 및 이력현상 분석)

  • Cho, Hong-Yeon;Lee, Khil-Ha;Cho, Kyung-Jun;Kim, Jun-Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.3
    • /
    • pp.213-221
    • /
    • 2007
  • In response to anthropogenic global warming due to a buildup greenhouse gas, the effect of the air temperature on water temperature has been noticed and some efforts have been made to build an air/water temperature relationship at the Masan Bay area by the Ministry of Maritime Affairs & Fisheries (MOMAF). As a result of analyzing the auto- and cross-correlation coefficient between air/water temperature, high correlation $(\sim0.9)$ is shown and the correlation coefficient of air temperature is higher than that of water temperature at the lag time less than approximately 10 days. Separate functions are fitted to the air/water relationship at the Masan Bay to take hysteresis into account. The slopes of the straight line for the rising limb are 0.829 and 0.774 for MA1 and MA2 station respectively, while 1.385 and 1.444 ($\sim1.75$ times larger) for the falling limb. Consequently, the seasonal hysteresis should be considered in order to determine an air/water relationship and accurately estimate the water temperature using the air temperature at Masan Bay.

Filling in Water Temperature Data of Aquatic Environments using a Pre-constructed Relationship

  • Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1125-1133
    • /
    • 2017
  • In this study a method for filling in missing data of river water temperature using a pre-constructed mathematical relationship between air and water temperatures is presented. A regression between water temperatures at individual stations and ambient air temperatures at nearby weather stations can provide a practical method for representing missing water temperature data for an entire region. Air and water temperature data that were collected from two test sites (one coastal and, one inland) were individually fitted to a nonlinear regression model. To consider seasonal hysteresis effects, separate functions were fitted to the data in the rising and falling limbs. A single-criterion, multi-parameter optimization technique was used to determine the optimal parameter sets. This method minimizes the differences between the time series of the measured and estimated data. The constructed air-water temperature relationship was subsequently applied to represent missing water temperature data. It was found that the RMSEs(MBEs) were in the range of $1.843-1.976^{\circ}C(-0.329-0.201^{\circ}C)$ and the coefficient of determination were in the range of 0.92-0.96. The results demonstrate that the predicted water temperatures using the regression equations were reasonably accurate.

An Analysis Finite Element for Element for Elasto-Plastic Thermal Stresses Considerating Strain Hysteresis at Quenching Process of Carbon Steel (I) - Analysis of temperature distribution - (탄소강의 담금질 처리과정에서 변형율이력을 고려한 탄소성열응력의 유한요소 해석(I) - 온도분포의 해석 -)

  • Kim, Ok-Sam;Cho, Eui-Il;Koo, Bon-Kwon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.8 no.3
    • /
    • pp.213-221
    • /
    • 1995
  • Temperature distribution, transformation and residual stresses generated during the quenching process of carbon steel. It follows many difficulties in the analytical considerations on those quenching process because of the coupling effects on temperature and metallic structures. In this paper one of the basic study on the quenching stresses was carried out for the case of the round steel bar specimen(SM45C) with 40mm both in its diameter and length. The temperature distributions considering strain hysteresis were numerically calculated by finite element technique. In calculating the transient temperature field, the heat flux between water and rod surface was determined from the heat transfer coefficient. The gradient of temperature is almost same to geometric of specimen. At early stage of the quenching process, the abrupt temperature gradient has been shown in the surface of the specimen.

  • PDF

Building a Nonlinear Relationship between Air and Water Temperature for Climate-Induced Future Water Temperature Prediction (기후변화에 따른 미래 하천 수온 예측을 위한 비선형 기온-수온 상관관계 구축)

  • Lee, Khil-Ha
    • Journal of Environmental Policy
    • /
    • v.13 no.2
    • /
    • pp.21-38
    • /
    • 2014
  • In response to global warming, the effect of the air temperature on water temperature has been noticed. The change in water temperature in river environment results in the change in water quality and ecosystem, especially Dissolved Oxygen (DO) level, and shifts in aquatic biota. Efforts need to be made to predict future water temperature in order to understand the timing of the projected river temperature. To do this, the data collected by the Ministry of Environment and the Korea Meteororlogical Administration has been used to build a nonlinear relationship between air and water temperature. The logistic function that includes four different parameters was selected as a working model and the parameters were optimized using SCE algorithm. Weekly average values were used to remove time scaling effect because the time scale affects maximum and minimum temperature and then river environment. Generally speaking nonlinear logistic model shows better performance in NSC and RMSE and nonlinear logistic function is recommendable to build a relationship between air and water temperature in Korea. The results will contribute to determine the future policy regarding water quality and ecosystem for the decision-driving organization.

  • PDF

Experimental investigation of growth and transport behavior of single water droplet in a simplified channel of PEM fuel cell (PEM 연료전지의 단순화된 공기극 채널 내 단일 물방울의 성장 및 이동 특성에 대한 실험적 연구)

  • Kim, Bok-Yung;Kim, Han-Sang;Min, Young-Doug
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.81-84
    • /
    • 2006
  • To investigate the characteristics of water droplet on the gas diffusion layer from both upper-view and side-view of flow channel, a rig test apparatus was designed and fabricated with L-shape acryl plate in a $1mm{\times}1mm$ micro-channel. This experimental device is used to simulate the single droplet growth and its transport process under fuel cell operating condition. As a first step, we investigated the growth and transport of single water droplet with working temperature and air flow velocity. The contact angle and its hysteresis of water droplet at departing moment are measured and analyzed. It is expected that this study can provide the basic understanding of liquid water droplet behavior in gas flow channel and GDL interface during the PEM fuel cell operation.

  • PDF

Variation Pattern Analysis on the Air and Surface Water Temperatures of the Yellow Sea Monitoring Buoy (황해중부부이에서 관측된 기온 및 표층수온의 변화양상 분석)

  • Cho, Hong-Yeon;Jeong, Jin-Yong;Shim, Jae-Seol;Kim, Seon-Jeong
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.5
    • /
    • pp.316-325
    • /
    • 2010
  • Harmonic analyses are carried out in order to obtain the major frequency components of the air temperature (AT) and surface water temperature (SWT) data monitored in the Middle Area of the Yellow Sea (Yellow Sea monitoring buoy). The analysis shows the annual and semi-annual components are predominant and the higher frequency components are relatively weak with contribution to the short fluctuations, i.e. below $0.2{\sim}0.5^{\circ}C$, in the AT and SWT. The standard deviation of the AT residual is 2.4 times larger than that of the SWT residual and the occurrence frequency distributions of the AT and SWT residual components are both closely fitted to a normal-distribution function. The variation pattern on the AT-SWT plane forms the clear continuous hysteresis loop in anti-clockwise direction which is composed of the AT-SWT rising period, AT-SWT falling period, and the constant SWT period in winter season.