• Title/Summary/Keyword: water need

Search Result 1,954, Processing Time 0.029 seconds

Application of System Dynamics Methodology for Comprehensive Analysis of the Water Business System (수도시스템 사업성과의 통합적 분석을 위한 시스템 다이나믹스 방법론 적용)

  • Lee, Sangeun;Park, Hyeyeon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • To consider business-based requirements beyond the existing roles of water supply, water utilities need enough methodology to integrate lots of related issues and to introduce effective decision-makings. On these grounds, this study modeled and simulated water business system using system dynamics approach. It is expected that formalised model can describe the actual system structurally and statistically, help utilities to predict their business performance and make decisions to solve chronic issues. Moreover, the case study of Y city gave political measures objectively and practically.

Evaluation of Relationship between Rainfall Intensity for Duration of Watersheds and Peak Water Levels of Local Rivers (지방하천 유역의 지속시간별 강우강도와 첨두수위 관계식 산정)

  • Choi, Han-Kuy;Kong, Ji-Hyuk;Baek, Hyou-Sun
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.71-78
    • /
    • 2011
  • As the need for predicting the flood stage of river from torrential downpouring caused by climate change is increasingly emphasized, the study, centered on the area of Gangwon-do Inje-gun and Jeongseon-gun of local river, is to develop peak water level regression equation by rainfall. Through the correlation between rainfall and peak water level, it is confirmed that rainfall according to duration and peak water level have a high correlation coefficient. Based on this, a relational expression of rainfall and peak water level is verified and then the adequacy of the calculated expression is analyzed and the result shows that a very accurate prediction is not easy to achieve but a rough prediction of the change of water level at each point is possible.

  • PDF

EVALUATION OF AN ACCIDENT MANAGEMENT STRATEGY OF EMERGENCY WATER INJECTION USING FIRE ENGINES IN A TYPICAL PRESSURIZED WATER REACTOR

  • PARK, SOO-YONG;AHN, KWANG-IL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.719-728
    • /
    • 2015
  • Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

Apply Low Impact Development for the reduction of runoff using SWMM model (SWMM 모형을 이용한 서암동지구에서의 유출수 저감을 위한 저영향개발기법 적용)

  • Woo, Won Hee;Lee, Tae Woo;Park, Youn Shik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.218-218
    • /
    • 2017
  • Urbanization increases impervious area and decreases the water quantity infiltrating into soil layers. This leads to lack of ground water, it could be possibly problematic for agricultural water for crop growth in lower basins, reducing not only ground water but also streamflow quantities. One such approach to minimize the impact of urbanization is to apply low impact developments (LIDs). LIDs are to decrease the percentage of impervious area so that infiltration rate is increased, there is a need to simulate the LIDs prior to the construction. LIDs in Storm Water Management Model (SWMM) are limited to be seven types, however it is often required to simulate LIDs more than seven types. Therefore an approach to apply eleven LIDs is provided in the study, updating the model parameters. A scenario containing eleven LIDs was given by the environmental decision makers, the effect of LIDs were simulated with the expected annual costs considering establishment and maintenance costs.

  • PDF

Current Status and Perspective of Biological Assessments of Water Environment in Korea (우리나라 생물학적 물환경평가의 현황과 미래)

  • Hwang, Soon-Jin;Kim, Nan-Young;Won, Doo Hee;An, Kwang Kuk;Lee, Jae Kwan;Kim, Chang Soo;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.757-767
    • /
    • 2006
  • Biological assessments are the primary tool for evaluating the biological condition of a water body and makes it possible to understand accumulative and long-term effect of stressors. They also provide reliable biological information for which disturbed systems are to be restored. Sustainable water environment is not enough with attaining only the clean water, but it should sustain healthy and diverse aquatic life. Aquatic organisms are affected by various factors, including not only water quality but also habitat condition and stressors, and thus good condition of both physical and chemical water quality is prerequisite for sustaining healthy organisms. Therefore, biological assessment, along with other physical and chemical assessments, are crucial for evaluating the health of a water body. Overall, sustainability of water environment demands the attainment and maintenance of ecological integrity, which is resulted from the combination of physical, chemical and biological integrity. The biological criteria will play very important role in the water resource management and policy issues, and thus bioassessment program should be fully implemented and supported eventually by the law. To keep ecosystem health of water environment safely from the toxic pollutants and other stressors, the following suggestions need to be considered in environmental quality standards in Korea. For the first step, the biological indicators need to be introduced in evaluating river quality condition; they provide a qualitative description of biological condition of water body. Secondly, the biological water quality standards using biotic indices should be developed and implemented under the consideration of characteristics of Korean river systems. Lastly, the ecological status classification regime (ESCR) should be developed and introduced; it could be used in quality assessment of the water environment in general. In developing ESCR, integration of physico-chemical, biological, and habitat parameters should be taken into account.

A Comparative Study on Drinking Water Quality of Simple Piped Water Supply Systems and Water Pumps According to Seasons (一部 農村 地域의 簡易 上水道와 Pump水의 季節別 水質에 關한 調査硏究 -춘성군 지성을 중심으로-)

  • Chung, Moon Ho
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.1
    • /
    • pp.21-31
    • /
    • 1984
  • The purpose of this study was to find out more effective schemes on safe water supply in rural area. Then, this study was carried out to investigate drinking water qualities of 20 simple piped water supply systems and 20 water pumps in Chun Sung County, Kang Won Province from 12th December to 24th December, 1983 and was compared this results with the previous results that had been carried out at the same sample sites from 1st July to 30th August, 1981. 1. This results of water quality in winter are better than the previous results in summer because this results are identified as safe 20%, unsafe 35% in simple piped water supply systems, safe 50%, unsafe 20% in water pumps and the previous results are identified as safe 1.8%, unsafe 78.6% in simple piped water supply systems, safe 5.5%, unsafe 73.6% in water pumps. 2. Water qualities of water pumps are better than that of simple piped water supply systems because the former is identified as safe 50%, unsafe 20% and the latter is identified as safe 20%, unsafe 35%. 3. Drinking waters that are in need of chlorination in winter as well as summer are 45% of simple piped water supply systems and 30% of water pumps.

  • PDF

A Study on Economic benefits for Water Control Device Installed with a Flush Valve on a Toilet (세척밸브 급수제어장치 설치에 따른 경제적 효과 분석)

  • Park, Kang-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.656-661
    • /
    • 2011
  • The amount of water resources that can be used tend to be decreased gradually. In contrast, the rapidly increasing water consumption is a problem that need to be addressed. Renovation and equipment replacement to improve energy efficiency and to reduce expenditure for building usage is required. But the excessive initial investment cost and the prolonged of pay back period may be uneconomical choice. Water usage for cleaning the toilet bowl accounts for 27%of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed for the economic effects. Water-saving valve was used 5.6 ${\ell}$/time for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}$/time. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.

The study on the quality standards of groundwater in Korea in comparing to the developed countries (우리나라와 선진국간의 지하수 수질기준에 관한 고찰)

  • Bang, Sang-Weon;Jung, Jae-Hyun
    • Journal of Environmental Policy
    • /
    • v.4 no.2
    • /
    • pp.57-82
    • /
    • 2005
  • In this study, we propose methods for. the efficient management and integrity of groundwater in response to a diminishing supply. As an alternative water resource for the future. we investigated and comparatively analyzed the quality standards of groundwater in the US (New York, Wisconsin and Texas), Austria, Netherlands, Canada, Japan and United Kingdom. These developed countries heavily depend on groundwater, more than 70%, for drinking water and apply those drinking water standards to groundwater quality. However, there exists few differences in the quality standards of groundwater among the countries, because each country possesses its own individual environment and management. In Korea, surface water pollution is getting serious and its water resources are diminishing. Therefore we propose several new quality criteria that many countries regulate at these days for their efficient management of groundwater. There is a need to divide BTEX criterion into Benzene, Toluene, Ethylbenzene and Xylene, individually. In. addition, it is needed to establish BTEX criteria into agricultural water and industrial water use standards as well as daily life use standards. Also, regulations for some PAHs, showing carcinogenicity, are required. Due to rapid industrialization various hazardous chemicals were utilized and their uses are increasing each year. Therefore, there is a strong need to introduce n~w standards and tighter regulations of the levels. At the same time, the criterion of nitrogenous compounds need' to be regulated individually in order to prevent the damage incurred by the compounds. Several developed countries have established standards for radon, previously caused environmental accidents in Korea. Therefore, we propose the necessity of groundwater quality standards for radon in this study.

  • PDF

Effect of corrosive water quality control and corrosion index monitoring in pilot scale pipeline simulator (파일럿 규모 모의관로에서 부식성 수질제어 효과와 부식지수 모니터링)

  • Kim, Do-Hwan;Kim, Yung-Jin;Son, Hee-Jong;Ryou, Dong-Choon;Ahn, Jun-Young;Kim, Cheolyong;Hwang, In-Seong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.183-192
    • /
    • 2018
  • Applicability of corrosion inhibitor was evaluated using pilot scale water distribution pipe simulator. Calcium hydroxide was used as corrosion inhibitor and the corrosion indices of the water were investigated. Corrosion indices, Langelier saturation index (LI) increased by 0.8 and calcium carbonate precipitation potential (CCPP) increased by 9.8 mg/L. This indicated that corrosivity of water decreased by corrosion inhibitor and the effects lasted for 18 days. Optimum calcium hydroxide dose was found to be 3~5 mg/L for corrosion inhibition. We suggest that monitoring of CCPP as well as LI need to be conducted to control corrosivity of water.

Liquidity Evaluation on the Horizontal Branch Pipe Connected to a Food Waste Disposer (디스포저에 의한 음식물류폐기물 횡지관 유동성 평가)

  • Jang, Choon-Man;Lee, Sang-Moon;Kim, Chul-Kyu;Park, Se-Joon;Yu, Jong-Chan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • This paper describes liquidity evaluation on the horizontal branch pipe connected to a food waste disposer and performance of five disposers marketed. Experimental apparatus for analyzing the five disposers has been introduced to measure vibration, sound level and power consumption of the disposers. Simulator for analyzing the required water velocity to avoid waste jam inside the pipe connected to a food waste disposer has been designed and constructed. The simulator can control some experimental parameters: pipe slope, disposer supply water quantity, food waste materials and operation time of a disposer. Throughout the experimental measurements of the disposers marketed, it is found that the time need to crash food waste is about 20 seconds on the average. At the same flow condition, increase rate of internal water velocity is accelerated as the pipe slope increases. The water velocity inside the pipe having 50 A and slope of 1/50 is 0.26 m/s when the water flowrate to supply the disposer is 16 l pm. Considering the specific gravity and adhesion property of food waste, water velocity of the horizontal branch pipe connected to a food waste disposer need to excess 0.26 m/s at least to avoid the waste blockage inside the pipe.