• Title/Summary/Keyword: water drain

Search Result 363, Processing Time 0.033 seconds

An Experimental Study on the Selection of the Proper Vocabularies for Evaluation about the Noise Emission from Water Supply and Drain Installations in Apartment Bathroom (공동주택 욕실 급배수 설비소음 평가를 위한 적정어휘 선정에 관한 실험적 연구)

  • Song, Guk-Gon;Kim, Hang;Lee, Tai-Kang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.679-682
    • /
    • 2007
  • This study aims to select the proper vocabularies for evaluation about the noise emission from water supply and drain installations in apartment bathroom. As a result of surveying overlapping vocabularies and scores of them for each sound sources, 'annoying', 'noisy', 'dynamic' and 'strident' are main unpleasant vocabularies to the noise from water supply and drain installations in apartment bathroom. And vocabularies such as 'dynamic', 'sudden', 'loudness', 'noisy' are classified into the first factor by analysis.

  • PDF

An Experimental Study to Improve the Characteristics of Electrode Type Humidifier (전극형 가습기의 특성을 개선하기 위한 실험적인 연구)

  • Park, Kyu-Hong;Song, Ha-Jin;Byun, Jae-Young
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.310-315
    • /
    • 2009
  • This investigation was performed to study the characteristics of electricity and heat transfer that occur in the cylinder of electrode type humidifier during the process of water evaporation. Measurements were made to obtain the amount of water evaporation, the consumption of electric power, electrical conductivity, etc according to the materials and shapes of electrode. When the humidifier was in non-drain controlled mode, the number and amplitude of current cycle per minute increased gradually with the lapse of time, whereas for drain controlled mode, it decreased about 40[%] after draining water. It was found that for non-drain controlled mode, the thermal efficiency of humidifier which used SS400, STS316 and wire net electrode type was about 95~96[%] and it was 2~4[%] higher than that of drain controlled mode. Also, it was shown that the thermal efficiency of humidifier which used neighboring six-phase electrode balanced electrically was 4[%] higher than that of existing six-phase type.

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

An study on the Noise rating of water supply and drain installations in apartment bathroom (급배수 설비소음 평가방법 선정을 위한 실험적 연구)

  • Lee, Tai-Kang;Ko, Kwang-Pil;Choi, Eun-Seok;Kim, Hang;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. The measurement procedure of water installations noise in apartment bathroom were established, so it is necessary to provide the evaluating method and criteria to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. After measuring the noise emission from the installations in many apartment bathroom, The noise were evaluated dB(A), N, NC index, To induce the appropriate method, the coefficient of the correlation among the evaluated numbers were analyzed. As a result, the dB(A) method is most easy to evaluating and very high correlated with N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

The Effects of Negative Pressure on Horizontal Drain Method (수명배수공법에 있어서 부압의 영향에 관한 실험적 연구)

  • 김정기;김지용;정승용;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.551-558
    • /
    • 2001
  • The horizontal drain method is one of methods improving reclamation ground. This method reduces consolidation time by using drained installed horizontally, and negative pressure is applied on end of these drains by vacuum pump. But, effective negative pressure still wasn't evaluated in applying this method to reclamation ground. To estimate optimum negative pressure, soil box test that make a model the in-situ by installing horizontal drains in the center is performed pressing different vacuum pressure In the laboratory, and the variations in settlement and volume of drained water through the drains during consolidation process were measured. Also, water content with distance from drain and with depth is measured after the test.

  • PDF

Analysis of seepage in trenching for surface desiccation of dredged soft ground (준설매립지반 표층건조처리를 위한 트렌치 굴착시 간극수의 침투해석)

  • 정하익;오인규;이용길;이승원;이영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.529-536
    • /
    • 2002
  • The purpose of this paper os to present and discuss some of flow and drain observed in modelling results. Because dredged fill ground of Yul-Chon located in the south coast of Korea is very soft, this ground should be improved after operation of surface stabilization. There are surface stabilization method such as chemical stabilization, desiccation, horizontally vacuum drain, replacement, and geosynthetics. In Yul-Chon, PTM(Progressive Trenching Method) is adopted to provide the necessity condition of surface desiccation. In the case trench in the dredged soft ground is formed by PTM equipment, pore water in the ground is drained through trench. There, drain and desiccation of surface ground increase, and bearing capacity is improved. In this research, when trench in the dredged soft ground is formed by PTM equipment, permeable characteristics and drain efficiency of pore-water are analyzed using SEEP/W software package. Results show variation of total head, pressure head, flux, hydraulic gradient, and flow quantity.

  • PDF

Prevalence of Microbiological Contamination on Water Purifiers at Lunchroom in Child Care Center (어린이집 급식실 정수기의 미생물학적 오염 평가)

  • Yoon, Mi-Hye;Kim, Jung-Beom;Oh, Hyuk-Soo
    • Korean journal of food and cookery science
    • /
    • v.28 no.5
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the prevalence of microbiological hazard on water purifiers at lunchroom in child care center was investigated. A total of 49 water purifiers and their purified cold water were sampled to test about the total aerobic bacteria, coliform bacteria, Bacillus cereus, Staphylococcus aureus, and Salmonella spp. Total aerobic bacteria was detected over 2.0 log CFU/mL in 6 out of 49 purified cold water (12.2%), ranged from 2.0 to 2.4 log CFU/mL, and the average number of total aerobic bacteria was showed to be 3.3 log CFU/drain spout. The drain spout turned out to be a major contaminant in water purifier and needs to be improved. Coliform bacteria were also detected in 7 out of 49 cold faucets (14.3%) and 7 out of 49 drain spouts (14.3%), but not detected in purified cold water. All samples were not contaminated with the pathogens tested in this study, except for B. cereus, which was contaminated on 2 out of 49 cold faucets (4.1%) and 4 out of 49 drain spouts (8.2%). All of B. cereus isolates produced enterotoxin, such as heamolysin BL enterotoxin (HBL) or non-heamolytic enterotoxin (NHE). The HBL was detected in 5 out of 6 B. cereus isolates (83.3%), including B. cereus PCF-11 and B. cereus PDS-30 isolate only produced NHE (16.7%). These results showed that the sanitary conditions of cold faucets and drain spouts should be improved promptly.

Investigation on Design Requirements of Feed Water Drain and Hydrogen Vent Systems for the Prototype Generation IV Sodium Cooled Fast Reactor (소듐냉각고속로 원형로 소듐-물 반응 압력완화계통의 급수배출 및 수소방출 설계 요건 연구)

  • Park, Sun Hee;Ye, Huee-Youl;Lee, Tae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.170-179
    • /
    • 2017
  • We investigated design requirements of feed water drain and hydrogen vent systems for the sodium-water reaction pressure relief system (SWRPRS) of the prototype generation IV sodium cooled fast reactor (PGSFR). We evaluated the areas of the gas vent pipe of the water dump tank and the length of the water drain pipe of the steam generator to rapid drain of the water steam inside the steam generator for the normal and refueling operations, respectively. We also calculated the diameter of the gas vent pipe of the sodium dump tank which met its design pressure.

Geotextiles Horizontal Drain between Earth Fills and Natural Soft Ground (토목섬유를 사용한 무처리 연약지반과 성토사이의 수평배수층)

  • Lee, Hyoung-Kyu;Kong, Kil-Yong;Kim, Hyun-Tae
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.129-138
    • /
    • 2002
  • This paper presents a study on the discharge capacity of geotextiles as a horizontal drain layer placed between the layers of earth fill and natural soft ground. Required discharge capacity of geotextiles as drain layers estimated by consolidation analysis is proportional to the consolidation coefficient of the ground soils and the width of the earth fills. The field discharge capacity of the geotextiles are measured by the hydraulic transmissivity test. And the results show wide variation according to the material characteristics of geotextiles, water content of the soils, vertical pressure, and etc. For the short horizontal drain length, geotextile filter mat can be used for the horizontal drain layer. And f3r the long drain($25{\sim}55m$), it is used for the drain together with Bord Drain.

A Development of the Trapped Water Drainage System to Prevent the Deterioration of Deck Slab and Pavement. (교면 포장 및 바닥판 손상 방지를 위한 내부 침투수 처리시스템 개발)

  • 조서연;한범성;이상달;이성수;이상순;이일용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1175-1180
    • /
    • 2001
  • Reinforced concrete deck slabs are directly affected by traffic loads and they are also susceptible to weather-related problems, such as cracking, reinforcement corrosion, spatting, scaling, delamination, leakage, efflorescence and so on. Some of these defects are caused by water which seeps through pavements and trapped between pavements and deck slabs. For durability of reinforced concrete deck slabs and pavements, it is very important to protect deck slabs and drain the trapped water out. To develop the trapped water drainage system, the following studies have been performed in Korea Highway Cooperation: related researches are reviewed; for six bridges, deck slabs are thoroughly investigated; new system to effectively drain the trapped water out is proposed; the proposed system is installed and evaluated. The proposed system is proved to be effective to drain the trapped water out and is expected to increase the durability of reinforced concrete deck slabs.

  • PDF