Browse > Article

An Experimental Study to Improve the Characteristics of Electrode Type Humidifier  

Park, Kyu-Hong (대림대학 전기과)
Song, Ha-Jin (대림대학 기계과, 태화)
Byun, Jae-Young (유한대학 컴퓨터제어과, 승일전자 연구소)
Publication Information
The Transactions of the Korean Institute of Electrical Engineers P / v.58, no.3, 2009 , pp. 310-315 More about this Journal
Abstract
This investigation was performed to study the characteristics of electricity and heat transfer that occur in the cylinder of electrode type humidifier during the process of water evaporation. Measurements were made to obtain the amount of water evaporation, the consumption of electric power, electrical conductivity, etc according to the materials and shapes of electrode. When the humidifier was in non-drain controlled mode, the number and amplitude of current cycle per minute increased gradually with the lapse of time, whereas for drain controlled mode, it decreased about 40[%] after draining water. It was found that for non-drain controlled mode, the thermal efficiency of humidifier which used SS400, STS316 and wire net electrode type was about 95~96[%] and it was 2~4[%] higher than that of drain controlled mode. Also, it was shown that the thermal efficiency of humidifier which used neighboring six-phase electrode balanced electrically was 4[%] higher than that of existing six-phase type.
Keywords
Electrode; Humidifier; Water Evaporation; Electrical Conductivity; Thermal Efficiency;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 박규홍 외 1인, "전극형 가습기용 전극설계(1)", 대한전기학회 하계학술대회 논문집, pp. 1190-1192, 2008
2 조 수 외 4인, "심야전력 기기의 인증시험, 대한건축학회 발표논문집, 제 11권 제 2호, pp. 409-412, 1991
3 한국기계연구원, "EMD를 이용한 열전달 촉진 기술", 과학기술처, pp. 46-59, 1992.8
4 김철주 외 4인, 열전달(SIXTH ED.), 교보문고, pp. 1091-1092, 2000
5 승일전자, "전극봉식 가습기 매뉴얼", 2008
6 박규흥 외 2인, "전극형 가습기용 전극설계(2)", 대한전기학회 하계학술대회 논문집, pp. 1213-1214, 2009
7 Ted Yeh, "The Optimum Concentration of Electrolytes for and Electrode Humidifier", Transaction of the Oklahoma Junior Academy of Science, 1999