• 제목/요약/키워드: water compartment

검색결과 127건 처리시간 0.024초

Water Quality Simulation of the Reservoir Using Ecological Model

  • Kim, Dong-Myung;Suk, Ji-Won;Kim, Sun-Young;Shin, Sang-Ik;Roh, Kyong-Joon
    • 한국환경과학회지
    • /
    • 제23권10호
    • /
    • pp.1755-1762
    • /
    • 2014
  • Water quality of the Koejong-reservoir was estimated by using the ecological model to evaluate the effects of industrial sewage discharge. State variables consist of POC, DOC, phytoplankton, DIP, DIN, DO and COD. Initial conditions for the compartment are applied to the model based on the observed results. The reproducibility was found to be satisfactory with the relative error ranging between the calculated value and the observed value. Water quality simulation was conducted by applying additional industrial sewage discharge into the Koejong-reservoir. The concentrations of COD, Chl.a, DIP and COD showed fluctuations of a narrow range. The increment percentages of Chl.a, COD and DIP were 26.6%, 20.2% and 18.2%, respectively. In the case of DO, the concentration decreased 4.8%.

Electricity Generation by Microbial Fuel Cell Using Microorganisms as Catalyst in Cathode

  • Jang, Jae Kyung;Kan, Jinjun;Bretschger, Orianna;Gorby, Yuri A.;Hsu, Lewis;Kim, Byung Hong;Nealson, Kenneth H.
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권12호
    • /
    • pp.1765-1773
    • /
    • 2013
  • The cathode reaction is one of the most seriously limiting factors in a microbial fuel cell (MFC). The critical dissolved oxygen (DO) concentration of a platinum-loaded graphite electrode was reported as 2.2 mg/l, about 10-fold higher than an aerobic bacterium. A series of MFCs were run with the cathode compartment inoculated with activated sludge (biotic) or not (abiotic) on platinum-loaded or bare graphite electrodes. At the beginning of the operation, the current values from MFCs with a biocathode and abiotic cathode were $2.3{\pm}0.1$ and $2.6{\pm}0.2mA$, respectively, at the air-saturated water supply in the cathode. The current from MFCs with an abiotic cathode did not change, but that of MFCs with a biotic cathode increased to 3.0 mA after 8 weeks. The coulomb efficiency was 59.6% in the MFCs with a biotic cathode, much higher than the value of 15.6% of the abiotic cathode. When the DO supply was reduced, the current from MFCs with an abiotic cathode decreased more sharply than in those with a biotic cathode. When the respiratory inhibitor azide was added to the catholyte, the current decreased in MFCs with a biotic cathode but did not change in MFCs with an abiotic cathode. The power density was higher in MFCs with a biotic cathode ($430W/m^3$ cathode compartment) than the abiotic cathode MFC ($257W/m^3$ cathode compartment). Electron microscopic observation revealed nanowire structures in biofilms that developed on both the anode and on the biocathode. These results show that an electron-consuming bacterial consortium can be used as a cathode catalyst to improve the cathode reaction.

토끼 동맥혈로 부터의 $D_2O$ 소실률에 대한 히스타민의 영향 (The Effect of Histamine on the Disappearance Rate of $D_2O$ from the Arterial Blood of Rabbits)

  • 김경태;신동훈
    • The Korean Journal of Physiology
    • /
    • 제1권1호
    • /
    • pp.23-32
    • /
    • 1967
  • Disappearance rate of injected $D_2O$ from the arterial blood as well as the effect of histamine on the rate were studied in rabbits. The concentrations of $D_2O$ in the serial arterial samples obtained through a Polyethylene tubing inserted into the carotid artery were assayed by the freezing point elevation method of Reaser. At zero time 3 ml of isotonic $D_2O$ in normal saline was injected into the jugular vein and at the same time serial sampling of arterial blood started. The serial sampling interval was either 7.7 sec or 12.3 sec. In the histamine treated animals histamine diphosphate (0,5 mg of histamine base) was injected intravenously 30 minutes prior to the zero time. The following results were obtained. 1. $D_2O$ concentration in arterial plasma water, x, was empirically obtained by the sum of 2 exponential terms of time, $x=Ae^{-k1t}+Be^{-k2t},$ and its theoretical basis was sought. The first term of the right member of the equation was regarded to be attributable to the compartment P which possessed instantaneous exchange of water with plasma. The second term was postulated to represent the poorly exchangeable compartment. 2. The constant A of the equation was evaluated as 4,37% and 14.3% in the control and histamine treated groups, respectively. B was 1.19% in the control and 0.849% in histamine treated animals. 3. The disappearance rates determined were; $k_1=0.0519{\pm}0.0221\;sec^{-1}\;K_2=0.00454{\pm}0.00247\;sec^{-1}$ in the control group. $k_1=0.1137{\pm}0.0290\;sec^{-1}\;K_2=0.00499{\pm}0.00204\;sec^{-1}$ in the histamine group. 4. In the histamine treated animals the disappearance rate of the first term was larger than that of the control animals, suggesting an enlarged size of the rapidly exchangeable compartment with regard to the plasma water. On the other hand the constant B was decreased by histamine administration, suggesting a distribution of $D_2O$ in an enlarged volume. This view was also made clear by comparing the apparent asymptotes to which the concentration curves of $D_2O$ approached in respective groups. The asymptotes in the histamine treated group showed lower values.

  • PDF

전기투석에 의한 발효아미노산의 분리

  • 오석중;문승현
    • 청정기술
    • /
    • 제3권2호
    • /
    • pp.28-30
    • /
    • 1997
  • 발효 아미노산을 분리하는 기존의 공정인 이온교환법에서 폐액 및 폐수처리에 따른 문제점을 해결하기 위한 새로운 분리공정으로 탈염 전기투석과 Water-splitting Electrodiaysis를 이용한 발효 아미노산의 분리 가능성 및 다양한 cell configuration과 막에 대한 성능 실험을 실시하였다. 실험결과 전기투석에 의해 경도물질을 제거한 후 양이온교환막과 bipolar 막으로 구성된 2-compartment WSED로 효과적으로 발효액에서 아미노산을 분리 할 수 있었으나 1가 양이온에 선택성을 지닌 양이온교환막으로는 아미노산의 분리가 어려움을 알 수 있었다.

  • PDF

병태(病態) 토끼에서의 Nalidixic Acid의 약물동태학적(藥物動態學的) 연구(硏究) (Pharmacokinetics of Nalidixic Acid in $CCl_4-Toxicated$ Rabbit)

  • 이민화
    • Journal of Pharmaceutical Investigation
    • /
    • 제13권2호
    • /
    • pp.51-58
    • /
    • 1983
  • In order to elucidate the effects of Panax Ginseng on the pharmacokinetic parameters of nalidixic acid in a patho-physiological changes, the kinetics of the disappearance of the drug from the blood, appearance in the bile and urinary excretion were studied in $CCl_4-toxicated$ rabbits. The pharmacokinetics of the drug nalidixic acid in rabbits were modeled by a two compartment. Total saponin, water extract from Panax Ginseng, significantly decreased biliary and urinary excretion of nalidixic acid.

  • PDF

원전 격실에 대한 최적 침수분석 방법 (Optimized Flooding Analysis Method for Compartment for Nuclear Power Plant)

  • 송동수;김상열
    • 에너지공학
    • /
    • 제21권1호
    • /
    • pp.75-80
    • /
    • 2012
  • 본 논문은 원자력발전소의 대형탱크 또는 배관파단에 따른 격실의 침수분석을 수행함에 있어 최적평가방법을 개발하여 원전에 실제로 적용하는 방법에 관한 논문을 작성하는데 목적이 있다. 주급수관파단사고 분석을 위해 RETRAN 전산코드를 사용하였다. 유출수 질량유량을 계산하는데 있어서 주급수제어밸브가 계통설계에 의거 원자로정지 후 5.0초 만에 닫히는 것으로 모델링하여 분석하였다. 출력 70% 운전시 방출유량이 가장 높은 것으로 나타났다. 방출 질량유량을 가지고 침수위를 계산한 결과 주급수관 격실의 최대 침수위는 1.43m로서 이는 안전성기기가 설치된 위치보다 낮아 원전의 안전정지에 미치는 영향이 없는 것으로 나타났다.

Towards Quantitative Assessment of Human Exposures to Indoor Radon Pollution from Groundwater

  • Donghan Yu;Lee, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권E2호
    • /
    • pp.43-51
    • /
    • 2001
  • A report by the national research council in the United States suggested that many lung cancer deaths each year be associated with breathing radon in indoor air. Most of the indoor radon comes directly from soil beneath the basement of foundations. Recently, radon released from groundwater is found to contribute to the total inhalation risk from indoor air. This study presents the quantitative assessment of human exposures to radon released from the groundwater into indoor air. At first, a three-compartment model is developed to describe the transfer and distribution of radon released from groundwater in a house through showering, washing clothes, and flushing toilets. Then, to estimate a daily human exposure through inhalation of such radon for an adult. a physiologically-based pharmacokinetic(PBPK) model is developed. The use of a PBPK model for the inhaled radon could provide useful information regarding the distribution of radon among the organs of the human body. Indoor exposure patterns as input to the PBPK model are a more realistic situation associated with indoor radon pollution generated from a three-compartment model describing volatilization of radon from domestic water into household air. Combining the two models for inhaled radon in indoor air can be used to estimate a quantitative human exposure through the inhalation of indoor radon for adults based on two sets of exposure scenarios. The results obtained from the present study would help increase the quantitative understanding of risk assessment issues associated with the indoor radon released from groundwater.

  • PDF

직접메탄올 연료전지에서 전지 성능에 대한 확산층의 영향 (Effect of Diffusion Layer for Cell Performance in DMFC)

  • 권부길;박경원;최종호;성영은
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2001년도 연료전지심포지움 2001논문집
    • /
    • pp.179-184
    • /
    • 2001
  • The diffusion layer within MEA(membrane electrode assembly) has been evaluated important factor for improvement of cell performance in DMFC. The diffusion layer in MEA structure leads to the reduction of catalyst loss in active catalysts layer as well as prevention of water-flooding in cathode. Cell performance is directly affected by interior properties of diffusion layer materials. Acetylene Black and $RuO_2$ with large pore size and low porosity compared to Vulcan XC-72R gave better performance caused by vigorous methanol diffusion and water removal. And $RuO_2$ as diffusion layer materials showed different behavior in anode and cathode compartment, that is, diffusion layers in anode and cathode side make methanol diffusion and water removal facilitate, respectively.

  • PDF

변전소 주변압기실 미분무수 소화시스템 성능평가를 위한 화재시나리오 (A Fire Scenario for Application of Water Mist System to an Indoor Power Transformer Room)

  • 최병일;한용식;김명배
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.52-57
    • /
    • 2005
  • 미분무수 소화시스템의 소화구조는 분무되는 물의 조건뿐만 아니라 방호대상 공간의 상태에도 의존하기 때문에 일반적인 설계기준을 마련 할 수 없는 실정이다. 따라서 보편적인 성능평가 방법도 있을 수 없기 때문에 방호 대상물과 공간이 결정되면 그에 적절한 성능평가 기준이 마련되어야 한다. 본 연구에서는 변전소 주변압기실에 미분무수 소화시스템을 적용하기 위하여 성능평가 기준을 제안하고자 한다. 이를 위하여 유사 화재사례 조사, 사고 분석, 유사 성능평가기준 분석 등을 수행하였다.

EFFECTS OF PROLONGED EXPOSURE TO THE SUN ON BODY WATER TURNOVER AND VOLUME OF THE BLOOD IN SWAMP BUFFALOES

  • Chaiyabutr, N.;Buranakarl, C.;Loypetjra, P.;Chanpongsang, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권1호
    • /
    • pp.47-52
    • /
    • 1990
  • During prolonged exposure to the sun for 8 h each day for 10 days in which the highest ambient temperature around 14:00 h was $39^{\circ}C$, buffaloes exposed to the sun without shade increased the turnover of body water by 35% and 76% on day 5 and day 10 of exposure respectively. The total body water markedly decreased on day five and this amount was maintained thereafter. Plasma and blood volumes did not change significantly on day five but markedly decreased on day 10. Packed cell volume significantly decreased on day five and day 10 of the exposure period. The reduction of packed cell volume on day 10 coincided with the decrease in total plasma water. On day 10 of the exposure, an increase in the rate of liquid flow from the rumen was noted. It is concluded that on the fifth day of exposure, the increase in the evaporative cooling process was attributed to initial mobilization of water from the intracellular compartment. The reduction of both plasma and cell volumes occurring from day five to day 10 indicated a loss of body water from both intracellular and extracellular compartments.