Browse > Article
http://dx.doi.org/10.5855/ENERGY.2012.21.1.075

Optimized Flooding Analysis Method for Compartment for Nuclear Power Plant  

Song, Dong-Soo (Korea Hydro & Nuclear Power Company)
Kim, Sang-Yeol (Central Research Institute)
Publication Information
Abstract
In this paper a realistic bounding method for flooding analysis following rupture of large size of thanks and piping is defined. Mass and energy release during main feedwater line break accident is analyzed with RETRAN code. It is modeled that the main feed water control valve is closed in 5.0 seconds after reactor trip. In result of the analysis, largest mass and energy is discharged at 70% reactor power. The flood sources for main feedwater room are calculated when piping failure occurs in the high energy line and medium energy line. Based on the result of flood level (1.43m), it is investigated that all of the safety-related environmental qualification equipments are well located above the flood level.
Keywords
Environmental Equipment Qualification; Mass/Energy Release; Flooding; Compartment;
Citations & Related Records
연도 인용수 순위
  • Reference
1 US NRC, Interim Staff Position on Environmental Qualification of Safety-Related Electrical Equipment, NUREG -0588, Rev.1, (1981).
2 US NRC, Environmental Qualification of Certain Electric Equipment Important to Safety for Nuclear Power Plants, REG Guide 1.89 Rev 1, (1984).
3 Ulchin 1&2 Final Safety Analysis Report, Chapter 3, 4, 6, 9, 11, 15.
4 Standard Review Plan, 6.2.1.4 Mass and Energy Release Analysis for Postulated Secondary System Pipe Ruptures, NUREG-0800, (1981).
5 이희도 외, "침수환경 평가보고서", 액트, (2011).