• Title/Summary/Keyword: warm storage

Search Result 55, Processing Time 0.023 seconds

Role of Kupffer Cells in Cold/warm Ischemia-Reperfusion Injury or Rat Liver

  • Lee, Young-Goo;Lee, Sang-Ho;Lee, Sun-Mee
    • Archives of Pharmacal Research
    • /
    • v.23 no.6
    • /
    • pp.620-625
    • /
    • 2000
  • The mechanisms of liver injury from cold storage and reperfusion are not completely under-stood. The aim of the present study was to investigate whether the inactivation of Kupffer cells (KCs) by gadolinium chloride ($GdCl_3$) modulates ischemia-reperfusion injury in the rat liver. Hepatic function was assessed using an isolated perfused rat liver model. In livers subjected to cold storage at $4^{\circ}C$ in University of Wisconsin solution for 24 hrs and to 20 min rewarm-ing ischemia, oxygen uptake was markedly decreased, Kupffer cell phagocytosis was stimulated, releases of purine nucleoside phosphorylase and lactate dehydrogenase were increased as compared with control livers. Pretreatment of rats with $GdCl_3$) , a selective KC toxicant, suppressed kupffer cell activity, and reduced the grade of hepatic injury induced by ischemia-reperfusion. While the initial mixed function oxidation of 7-ethoxycoumarin was not different from that found in the control livers, the subsequent conjugation of its meta-bolite to sulfate and glucuronide esters was suppressed by ischemia-reperfusion, CdCl$_3$restored sulfation and glucuronidation capacities to the level of the control liver. Our findings suggest that Kupffer cells could play an important role in cold/warm ischemia-reperfusion hepatic injury.

  • PDF

Changes of Lead Content during Warm Storage of Canned Coffee Drinks (캔 커피의 온장 시 납 함량의 변화)

  • Lee, Kyung-Ju;Lee, Mi-Gyung
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.228-230
    • /
    • 2007
  • In this study, we investigated the change in lead content of canned coffee drinks while kept for 16 weeks in an incubator adjusted to $65^{\circ}C$. Our research aim was to ensure the safety of canned coffee purchased from vending machine and stores. The lead analysis were conducted by graphite furnace atomic absorption spectrometry after wet digestion using concentrated nitric acid. The results showed that the lead contents of all examined samples were very low at a level of not detected to 0.033 mg/L, and below 2 mg/kg, the Korean regulatory limit for the commodity. Also, no increase in lead content was observed over the elapsed time. Therefore, it appears that lead is not a hazard and need not be a concern in drinking canned coffee.

Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System (수막재배 단동비닐하우스의 태양열 축열이용 효과분석)

  • Lee, S.H.;Ryou, Y.S.;Moon, J.P.;Yun, N.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

Performance of the Cold Latent Storage System (냉열잠열축열조의 성능해석)

  • Yoon, Ho Sik;Ro, Sung Tack
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.456-465
    • /
    • 1988
  • The performance of the cold latent heat storage is investigated by experiment and by a simplified analytic approach. The heat storage tank has eight horizontal circular tubes and one path of refrigerant evaporating tube. The phase change material in the heat storage tank is water which is frozen by evaporating refrigerant of refrigeration system and melts by the warm air in the heat storage tank. In the experiment, the performance has been studied by the various conditions including the initial water temperature on solidification and flow rate and temperature of air. The rate of recovered heat has been simulated by a simplified model and the results shows a good agreement. In solidification process, initial water temperature causes time delay corresponding to the sensible heat and it is found that the shape of evaporator is important. In melting process, the recovered heat rate from the heat storage tank is proportional to $Re^{0.8}(T_{bi}-T_f)$ of air where $T_{bi}$ and $T_f$ indicate temperatures of inlet air and phase change, respectively. And the deminishing rate of the recovered heat is higher for the higher heat rate.

  • PDF

1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents (Iopamidol과 Ioversol 제제 조영제의 사용 후 보관 기간에 따른 1H-NMR 분석)

  • Han, Beom-Hee
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.239-245
    • /
    • 2021
  • Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.

Reliabilty of a System with Standbys and Spares

  • Park, Kyung-Soo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.3 no.2
    • /
    • pp.83-91
    • /
    • 1977
  • This paper investigates the reliability characteristics of a system consisting of a unit operating on-line and backed by n spares among which m units are kept "warm" as standbys ready to go on-line. The on-line unit has an arbitrary lifetime distribution, while the warm standbys have exponential failure time distributions. The Failed units are repaired and brought back to service. The cold spares do not fail while in storage. Solution of this extremely complicated queuing problem using a "renewal counting" approach is presented and extended to the situation where the warming-up takes non-negligible time. Finally, an approach to the economic system management is discussed, considering the long-run availability, cost of keeping spares and repair facility, and the associated cost of restarting the system, after a system failure. The model presented in this paper will have many applications including the determination of the spares inventory and the number of field spares to be "carried".

  • PDF

Design and manufacture of Bi-2223 HTS current leads for SMES magnet

  • Oh, S.S.;Cho, J.W.;Ha, H.S.;Sim, K.D.;Ha, D.W.;Seong, K.C.;Kwon, Y.K.;Ryu, K.S.;Kim, S.H.;Jang, H.M.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.236-240
    • /
    • 2000
  • Bi-2223 HTS current leads for a superconducting magnetic energy storage(SMES) magnet were designed and manufactured. The HTS leads composed of Bi-2223/AgAu tapes and stainless steel former were connected to conventional vapor-cooled copper leads. The heat input to the liquid helium through the HTS lead was 0.39 W/lead when the warm end part's temperature is 65 K. And, the critical current of the HTS leads was about 1.6 kA when the warm end part's temperature is 80 K. The measured those values are well consistent with computed values.

  • PDF

Storage and Acceptability of a Smoked Sebastes schlegeli Product (훈연처리에 의한 조피볼락의 저장성 및 기호도)

  • Lee, In-Sung;Kim, In-Cheol;Chae, Myoung-Hee;Chang, Hae-Choon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.36 no.11
    • /
    • pp.1458-1464
    • /
    • 2007
  • This study was conducted to develope a new type of ready-to-eat smoked Sebastes schlegeli product with high acceptability and extended shelf-life. A Sebastes schlegeli was salted at 4% salt concentration for 6 hr at $4^{\circ}C$. The cold smoking conditions for the salted Sebastes schlegeli consisted of drying for 2 hr at $22{\sim}24^{\circ}C$ followed by smoking for 2 hr at $22{\sim}24^{\circ}C$. The warm smoking conditions for the salted Sebastes schlegeli consisted of drying for 2 hr at $22{\sim}24^{\circ}C$, smoking for 2 hr at $22{\sim}24^{\circ}C$, and smoking again for 30 min at $47{\sim}50^{\circ}C$. The rancidity of the smoked Sebastes schlegeli did not change after 1 year storage at $-20^{\circ}C$ by monitoring the iodine value, peroxide value, and acid value. The number of viable cells in the cold and warm smoked samples were counted as $7.4{\times}10^5$ and $6.2{times}10^5$ CFU/g, respectively. Viable cells were not detected after 1 year of storage at $-20^{\circ}C$. The sensory evaluations of the processed Sebastes schlegeli showed that elastic texture increased with smoking as compared to with salting. There were no significant differences between cold and warm smoking in terms of sweetness, elastic texture, color, and smoke flavor. However, for overall acceptability, preference were in the oder of cold smoked, warm smoked, and salted.

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Laboratory Test on Total Flow Control for Ice Slurry System with Inverter Fed Motor Pump (인버터구동 모터펌프를 이용한 아이스 슬러리형 빙축열시스템 전유량제어 운전시험)

  • Choi, Byoung-Youn;Lee, Kyoung-Ho;Lee, Sang-Ryoul;Lee, Hak-Joo
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.260-265
    • /
    • 2001
  • This paper describes total flow control of an ice slurry system for pump energy saving. Similar turbo machinery has a characteristic that input power ratio is proportional to the three time of revolution speed ratio. To reduce the energy cost of brine pump in ice slurry storage systems, inverter is adapted instead of 3-way valve to control the speed of brine pump motor. One type of cooling load profile was used as driving load of the system, generated by a boiler and warm water storage tank. As results of the laboratory test, energy consumption and cost of the pump were reduced by 11.4%.

  • PDF