DOI QR코드

DOI QR Code

1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents

Iopamidol과 Ioversol 제제 조영제의 사용 후 보관 기간에 따른 1H-NMR 분석

  • Han, Beom-Hee (R&D Team of Radiation Science Technology Laboratory)
  • 한범희 (방사선과학기술연구소 연구개발팀)
  • Received : 2021.06.17
  • Accepted : 2021.06.28
  • Published : 2021.06.30

Abstract

Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.

Keywords

References

  1. Kim MC, Kim KK, Kweon DC, Lim CH, Kim HJ, Im IC, et al. Textbook of computed tomography. Chung Ku Publisher; 2020.
  2. Wang CL, Cohan RH, Ellis JH, et al. Frequency, outcome, and appropriateness of treatment of nonionic iodinated contrast media reactions. AJR. 2008;191(2):409-15. https://doi.org/10.2214/AJR.07.3421
  3. Kang YH. The Precaution duty and the product liability for adverse reactions to the contrast media. Journal of Radiological Science and Technology. 2007:30(4):305-11.
  4. Kwon KS. Anlaysis of Adverse Reactions to CT contrast Medium. University of Ulsan; 2004.
  5. Thrall JH. Adverse reactions to contrast media. In: Swan-son DP, Chilton HM, Thrall JH(eds) Pharmaceuticals in medical imaging. 1st ed. New York: Macmillan; 1990:253-77.
  6. Cohan RH, Ellis JH, Garner WL. Extravasation of radiographic contrast material: Recognition, prevention, and treatment. Radiology. 1996;200: 593-604. https://doi.org/10.1148/radiology.200.3.8756899
  7. Kim SH, Park JH, Kim YL, et al. Experimental tissue damage after subcutaneous injection of water soluble contrast media. Invest Radiol. 1990;25:678-85. https://doi.org/10.1097/00004424-199006000-00011
  8. Sistrom CL, Gay SB, Peffley RN. Extravasation of iopamidol and iohexol during contrast-enhanced CT: A report of 28 cases. Radiology. 1991;180: 707-10. https://doi.org/10.1148/radiology.180.3.1871281
  9. Penry JB, Livingstone JB. A comparison of diagnostic effectiveness and vascular side-effects of various diatrizoate salts used for intravenous pyelography. Clin Radiol. 1972;23:362-9. https://doi.org/10.1016/S0009-9260(72)80068-0
  10. Evill CA, Wilson Al, Sage MR. Chemotoxic effects of low-osmolar contrast media on the blood brain barrier. Invest Radiol. 1990;25:S82-3. https://doi.org/10.1097/00004424-199009001-00038
  11. Blum W, Weinberg U, Shenkman L, et al. Hyperthy-roidism after iodinated contrast medium. N Engl J Med. 1974;291:24-5. https://doi.org/10.1056/NEJM197407042910107
  12. Sidhu PS, Dawson P. Guidelines for the management of reactions to intravenous contrast media. London: Royal College of Radiologists; 1993.
  13. Dawson P, David O, Ronald G. Textbook Contrast Media. British Library; 1999.
  14. Lee SK. The analysis of NMR spectrum. Hanrimwon; 2014.
  15. Cardinal HN, Holdsworth DW, Drangova M, et al. Experimental and theoretical X-ray imaging performance comparison of iodine and lanthanide contrast agents. Med Phys. 1993;20:15-31. https://doi.org/10.1118/1.597134
  16. Yu SM, Han DK, Hong JW. Comparative analysis of death-related iodide contrast media due to adverse reactions of contrast media in computed tomography. Journal of Radiological Science and Technology. 2021;44(1):47-52. https://doi.org/10.17946/JRST.2021.44.1.47
  17. Han BH. Physicochemical analysis according to temperature changes of iopamidol and ioversol formulation. Journal of Radiological Science and Technology. 2020;43(4);273-80. https://doi.org/10.17946/JRST.2020.43.4.273
  18. Dongkook Life Science. 2017; from: http://www.dkls.co.kr/product/view.php?type=medicine&idx=21.