• Title/Summary/Keyword: voltage fluctuation

Search Result 278, Processing Time 0.024 seconds

Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

Random Dopant Fluctuation Effects of Tunneling Field-Effect Transistors (TFETs) (터널링 전계효과 트랜지스터의 불순물 분포 변동 효과)

  • Jang, Jung-Shik;Lee, Hyun Kook;Choi, Woo Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.179-183
    • /
    • 2012
  • The random dopant fluctuation (RDF) effects of tunneling field-effect transistors (TFETs) have been observed by using atomistic 3-D device simulation. Due to extremely low body doping concentration, the RDF effects of TFETs have not been seriously investigated. However, in this paper, it has been found that the randomly generated and distributed source dopants increase the variation of threshold voltage ($V_{th}$), drain induced current enhancement (DICE) and subthreshold slope (SS) of TFETs. Also, some ways of relieving the RDF effects of TFETs have been presented.

Active and Reactive Power Control of ESS in Distribution System for Improvement of Power Smoothing Control

  • Shin, Seong-Su;Oh, Joon-Seok;Jang, Su-Hyeong;Cha, Jae-Hun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1007-1015
    • /
    • 2017
  • This paper proposes a new control technique of energy storage system (ESS) for smoothing the active power of renewable energy sources (RES) such as photovoltaic and wind turbine generation. As the penetration of RES into grid increases, it is difficult to maintain the permissible level of power quality, that is, voltage and frequency fluctuation in power systems. To solve this problem, ESS control methods using low pass filter (LPF) have been proposed for mitigating the fluctuation of RES output. However, those have a lot of drawbacks which need to be supplemented. Hence, this paper presents the improved active power control with additional reactive power control for maintaining power quality properly. The proposed method minimizes the capacity of ESS to be required for smoothing RES output fluctuation through mitigation of phase delay problem in LPF. In addition, the voltage regulation improves by using additional reactive power control. The proposed method was verified through simulation analysis using PSCAD/EMTDC.

Seamless Transfer Method of MPPT for Two-stage Photovoltaic PCS (태양광 발전 시스템의 무순단 MPPT 운전 모드 절체 기법)

  • Park, Jong-Hwa;Jo, Jongmin;An, Hyunsung;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.2
    • /
    • pp.233-238
    • /
    • 2018
  • This paper proposes a seamless MPPT operation mode transfer method of photovoltaic system. The photovoltaic system consists of a DC-DC boost converter, a DC-Link, and a 3-level neutral point clamp (NPC) type inverter. The PV voltage fluctuates due to the output characteristics of the solar pane1 depending on the irradiation amount and the temperature. The photovoltaic system requires seamless MPPT mode transfer method that the discontinuity does not occur in order to supply the stable power to system without affecting the fluctuation of the PV voltage. MPPT operation is divided into two modes by the voltage reference. Under the condition that the PV voltage is below 650V, the DC-DC boost converter performs MPPT through duty control based on perturb & observe (P&O) method, and the inverter conducts DC-link voltage and grid current controls in synchronous reference frame. On the other hand, when the PV voltage exceeds above 650V, inverter performs MPPT in accordance with the variation of DC-link voltage control while the converter stops operating. Two MPPT operation modes is smoothly transferred through the proposed method that DC-link voltage or grid current commands are appropriately adjusted from the certain criteria. The feasibility of the MPPT operation mode transfer method is verified using a 10kW solar photovoltaic system, experimental results have good performances that the fluctuation of PV current is reduced to 100%.

SNU 1.5 MV Van de Graaff Accelerator (V) -on the Operation of the High Voltage Stabilization System- (NU 1.5MV 반데그라프 가속기 (V) -고전압 안정화 계통의 동작-)

  • Bae, Y.D.;Bak, H.I.;Chung, K.H.;Woo, H.J.;Choi, B.H.
    • Nuclear Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.115-121
    • /
    • 1987
  • A high voltage stabilization system for the SNU 1.5MV Tandem Van do Graaff accelerator was set up and its operational characteristics were examined and optimized. The optimum parameters of beam transport system were experimentally determined, and under the proper condition the accelerated proton beam current of 350nA was obtained at the target chamber. Without the high voltage stabilization the observed magnitude of voltage fluctuation was $\Delta$V/ V=5.2$\times$10$^{-3}$ without ion beam and 7.2$\times$10$^{-3}$ with ion beam, respectively, and its apparent ripple frequency for voltage fluctuations was about 3Hz or less. Through the optimized operation of the high voltage stabilization system, the terminal voltage fluctuation was reduced to $\Delta$V/V=2.45$\times$10$^{-4}$ and the energy stability with $\Delta$E/E=2.44$\times$10$^{-4}$ was steadily maintained at the 247.3kV terminal voltage, and the stabilization factor was deduced to be 29.4.

  • PDF

Study On The Characteristic Of System Fluctuation Under Large Generator Unit Outage (대전원타락사고시의 계통동요특성 해석)

  • 송길영;이종훈;김영창
    • 전기의세계
    • /
    • v.24 no.2
    • /
    • pp.71-77
    • /
    • 1975
  • This paper describes the results of a study for the stability of power system when the Kori Nuclear #1 P/P is operated with existing system. First, a transient disturbance, which effects the stability of entire power system, was analysed and to cope with the problem a load shedding method was studied to recover the fluctuation of the power system. Second, transient stability problem was studied when three phase fault occurs in 345 Extra High Voltage power System, and from this result, it was found to be highly effective that high speed protecting device should be provided and operated to recover the fault.

  • PDF

Adaptive Harmonic Control for DC Input Voltage Fluctuation of PWM Inverter (PWM인버터의 DC입력전달 맥동에 대한 고조파 적응제어)

  • 이윤종;임남혁
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.11
    • /
    • pp.896-904
    • /
    • 1989
  • PWM techniques which eliminate and reduce harmonics of output voltage in PWM Inverter driving System with fluctuating input volotage are described. First, harmonic factors are analyzed from harmonic equation of general PWM waveform and by examination of control possiblity of each factor, controllable factor is selected. Applying controllable factor to NPWM, PWM techniques using reference wave and carrier wave modulation are introduced. Actually, by the experiment applied with this strategy, the reduction of harmonics of output voltage is confirmed.

  • PDF

Simulation for voltage fluctuations of Grid-connected Wind Turbine Generators by Simulink (Simulink에서 풍력발전 연계시스템의 전압변동 시뮬레이션)

  • Ahn, Duck-Keun;Ho, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1389-1391
    • /
    • 2003
  • The development of wind turbine power generation has grown during the past ten years. An important question, when installing wind turbines with the generator connected directly to the grid, is holt much the voltage quality will be affected by the uneven power production and by the connection of the wind turbine to the grid. This paper presents the voltage fluctuation of grid-connected WTG(wind turbine generators) by MATLAB/Simulink.

  • PDF

Adaptive Harmonic Control against DC Input Voltage Fluctuation of PWM Inverter by Instantaneous Integration (순시적분에 의한 PWM인버어터의 직류 입력전압 맥동에 대한 고조파 적응제어)

  • Park, Sung-Jun;Kwon, Y.A.;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.721-723
    • /
    • 1993
  • A PWM switching control strategy based on instantaneous integration concept for reducing hamonic components of inverter system with fluctuating input voltage is presented. Applying this strategy to single phase full bridge PWM inverter through bipolor switching method and unipolor switching method, reduction of hamonic components of output voltage and current is demonstrated through simulation. The system operation is examined and confirmed by experiments.

  • PDF