Electric Power Line Dips Measurement Using Drone-based Photogrammetric Techniques (드론 기반 사진측량기법을 활용한 고압 송전선의 처짐량 측정)

  • Kim, Yu Jong;Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2017
  • High voltage power transmission lines have been to keep the proper dip for maintenance. Powerline dips at a random point are conventionally measured by the direct or indirect observation but it is not only unsafe but labor-intensive. Therefore in this study we applied the photogrammetric technique to remotely measure the powerline dips. Since it is not easy to extract conjugate points from linear powerlines, we exploited the epipolar lines acrossing the powerlines for 3D mapping of the powerlines and dip measurements. The vertical mapping accuracy estimated at two field-surveyed power line points was 15~16cm that are within 5% of deflection at the points and less than 3% of the powerline dip.

Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier (3상 위상제어 정류기를 위한 DVR의 반응시간 최적화)

  • Park, Chul-Woo;Joung, Sookyoung;Ryu, Jee-Youl;Lee, Dae-Seup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.

A study on the permissible range of voltage dips and the response time of DVR in 3-phase phase-controlled rectifier (3상 위상제어 정류기에서 DVR의 응답시간과 허용 가능한 순시저전압의 범위에 대한 연구)

  • 한무호;권우현;박철우
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.325-333
    • /
    • 2004
  • It is investigated that the relation between the response time of DVR(Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system which protects the 3-phase phase-controlled rectifier from voltage dip. As a result, the permissible range of voltage dip is presented in the 3-phase phase-controlled rectifier, and it is presented that the range of voltage dip which can be compensated according to the DVR s response time. when the DVR compensates voltage dip, Using the proposed method, the DVR s response time can be determined from the parameters of 3-phase phase-controlled rectifier and the possible compensation range of voltage dip, and it is possible to use the control system which have an appropriate speed. Therefore, the use of excessively fast device can be avoided, and the stability of the overall system is improved. Also the reliance of DVR about the 3-phase phase-controlled rectifier can be verified.

Improved Grid Voltage Control Strategy for Wind Farms with DFIGs Connected to Distribution Networks

  • Zhang, Xueguang;Pan, Weiming;Liu, Yicheng;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.495-502
    • /
    • 2012
  • This paper presents an improved grid voltage control strategy for wind farms with doubly-fed induction generators (DFIGs) connected to distribution networks based on an analysis of the operation limits of DFIG systems. A modified reactive power limit calculation method in different operation states is proposed and a reactive power control strategy during grid voltage dips/rises is further discussed. A control strategy for compensating unbalanced grid voltage, based on DFIG systems, by injecting negative sequence current into the grid through the grid side converter (GSC) is proposed. In addition, the negative current limit of the GSC is discussed. The distribution principle of the negative sequence current among the different DFIG systems in a wind farm is also introduced. The validity of the proposed voltage control strategy is demonstrated by Matlab/Simulink simulations. It is shown that the stability of a wind farm and the power grid can be improved with the proposed strategy.

A New Flux Tracking LVRT Control Scheme for Doubly Fed Induction Generators

  • Park, Sun-Young;Ahn, Hyung-Jin;Lee, Dong-Myung
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.3
    • /
    • pp.306-312
    • /
    • 2013
  • Doubly fed induction generator (DFIG) systems widely used globally are highly sensitive to the grid disturbance due to the structure that the stator is connected to the grid. In the past, when a grid fault occurs in order to prevent a system, generators are separated from the grid regardless of the fault duration time. Recently, however, the grid connection standards(Grid Code)says that for the failures removed within a certain time, the generator remains operation without separating from the grid. This paper proposes a new flux tracking LVRT(Low-Voltage Ride Through) control based on system modeling equations. The validity of the proposed strategy has been demonstrated by computer simulations.

Selection of Motor Starting Method by Numeric Simulation (기동시뮬레이션 방법에 의한 유도전동기 기동방식 선정)

  • Chang, Chung-Koo;Suh, Sang-Jin;Lee, Min-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.817-820
    • /
    • 2002
  • Since a squirrel cage induction motor by NEMA Design types is designed to withstand full-voltage starting, direct starting method can be the most economical one. Starting a squirrel cage motor from standstill by connecting it directly across the line may allow inush currents of approximately 500-600% of rated current at lagging power factor of 35-50%. For many of the large motors, the starting inrush current may be great enough to cause voltage dips, which may adversely affect the building's lighting system. Electric utilities also have restrictions on starting currents, so that voltage fluctuations can be held to prescribed limits. Therefore the need for choosing the most appropriate method of motor starting is quite essential. In this paper, we proposed a plan for the selection of the most appropriate motor starting method, first by way of numeric simulation using manufacturer's data and second by way of actual experience. So far, more often than not, the selection of motor starting method has been accomplished only as regards to the capacity of the motor and the frequency of starting and stopping. But nowadays such high-tech apparatus as soft starters are being developed, and we are on the position to give more attention to clarify the way of selection of the motor starting method.

  • PDF

Design and Analysis of Large Induction Motor Control Coping with Voltage Sag (순간전압강하 극복을 위한 대용량 유도전동기 제어방식 설계 및 해석)

  • Cho, Sung-Don;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1056-1058
    • /
    • 1998
  • Voltage dips caused by transmission system faults are usually of a short duration. High speed relaying and breaker operation will typically limit the disturbance to 0.1 seconds. Most motor controllers obtain their control power directly from the bus by means of a control transformer. Under this condition, a voltage dip can cause the contactor to drop out. disconnecting the motor from the line. The rapid re-energizing of the controller is in effect a fast reclosure which may result in motor damage. The time delay re-energizing of controller will result in a greater loss of speed and possibly loss of stability. Other means of controller can be used to prevent the motor from being disconnected from line during the fault. This can be accomplished by DC power controller or mechanically latched controller. This paper demonstrates that DC power controller or mechanically latched type controller to prevent the motor from being disconnected from line during the fault is, the most effective in minimizing speed reduction, transient motor current, transient motor torque and transient shaft torque by EMTP calculation.

  • PDF

Injection of Rotor Current for DFIG-Based Wind Turbine to Improve Transient State under Voltage Dips (DFIG 풍력터빈의 계통 저전압 발생 시 과도상태 개선을 위한 회전자 전류 주입 방법)

  • Kim, Tae-Hyeong;Kim, Soo-Bin;Song, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.465-466
    • /
    • 2019
  • 전 세계적으로 지구 온난화와 화석연료 고갈로 재생 에너지의 수요가 증가하고 있다. 풍력발전은 전체 재생 에너지의 20% 이상을 차지하며, 2020년 까지 792 GW가 설치될 것으로 전망하고 있다. DFIG(이중여자 유도 발전기)타입의 풍력 터빈은 전력변환장치의 용량이 작은 장점이 있지만, 고정자 권선이 계통과 연결되어 계통 저전압 발생 시 제어가 어렵다는 단점이 있다. 본 논문에서는 계통 저전압 발생 시 고정자 회로의 과도상태에 대해 정리하고, 과도상태를 개선하기 위한 회전자 전류 주입 방법 대해 제시하고 시뮬레이션을 통해 검증하였다.

  • PDF

Electrical spin injection and detection in epitaxially grown Fe/GaAs (001) hybrid structure (에피성장된 Fe/GaAs (001) 적층구조에서의 스핀 주입 및 검출)

  • Lee, Tae-Hwan;Koo, Hyun-Cheol;Kim, Kyung-Ho;Kim, Hyung-Jun;Han, Suk-Hee;Lim, Sang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.357-357
    • /
    • 2008
  • Spin injection experiment is conducted in epitaxially grown Fe/GaAs hybrid structure. For the formation of Schottky tunnel barrier between Fe and GaAs layers, highly n-doped GaAs layers are grown after n-doped channel layer. A non-local measurement, a voltage measurement probes do not contain a charge current path, is used for detecting only the chemical potential differences by the spin transport. As a result, the dips that are nicely matched with antiparallel region are obtained.