• Title/Summary/Keyword: view on science

Search Result 3,477, Processing Time 0.035 seconds

Science Gifted Middle School Students' Philosophical Views on Scientific Knowledge and Effects of Discussing and Reading Related to the Knowledge (중학교 2학년 과학영재들의 과학 지식에 대한 과학철학적 관점과 이에 대한 토론 및 읽기 활동의 효과)

  • Hong, Sang-Wook;Jeong, Jin-Woo;Jang, Myoung-Duk
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.397-405
    • /
    • 2002
  • This study investigated science gifted middle school students' philosophical views on scientific knowledge, and the effects of discussing and reading related to the knowledge. Ten eighth-graders in a science gifted class participated in this study. The results can be summarized as follows: 1, At the beginning, the students had one of six positions: (a) relativism (n = 2); (b) falsificationism (n = 2); (c) borderline between relativism and eclecticism (n = 1); (d) borderline between falsificationism and eclecticism (n = 3); (e) borderline among relativism, falsificationism, and eclecticism (n = 1); and (f) borderline inductivism and eclecticism (n = 1). This result indicated that most students had on almost modern philosophical view of scientific knowledge. 2, Some students, who had chosen the item of inductivism in some questions of the instrument at the beginning, maintained their selection despite discussions and readings related to scientific knowledge. The data were examples which indicated the difficulty of changing from a traditional view to a modern view of scientific knowledge.

The Influence of Task Orientation and Preferred Self-View Size on Self-View Preference: Testing the Moderated Mediating Effect of Social Anxiety (과업지향정도 및 선호하는 화면크기가 비디오 피드백 기능 선호도에 미치는 영향: 사회불안의 조절된 매개효과 검증)

  • Peck, Soojin;Han, Kwanghee
    • Science of Emotion and Sensibility
    • /
    • v.25 no.3
    • /
    • pp.3-14
    • /
    • 2022
  • With the increase of video conferencing users and the development of technology, the situations where video conferencing is used and the layout of video conferencing interfaces are diversifying. Social anxiety affects video conferencing communication and is closely related to the self-view function, which is characteristic of video conferencing. The self-view function is part of the video conferencing interface that provides a small preview of one's own camera feed. Self-view is known to degrade work performance and cause fatigue; however, it is set as the default function on video conferencing software in a way that users generally prefer. This study used an online survey to study the effect of task orientation, preferred self-view size, and social anxiety on video feedback preference. Participants responded to questions assessing work orientation, social anxiety level, preferred self-view size, and self-view preference. The results showed that preferred self-view size mediates task orientation and video feedback preference. There was no significant difference in the mediating effect of the preferred self-view size according to the degree of social anxiety. These results offer insights into the interactions between users and video conferencing software and provide information that can be useful for designing video conferencing interfaces.

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography

  • Moudi, Ehsan;Haghanifar, Sina;Madani, Zahrasadat;Bijani, Ali;Nabavi, Zeynab Sadat
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.147-151
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the effects of metal artifacts on the accurate diagnosis of root fractures using cone-beam computed tomography (CBCT) images with large and small/limited fields of view (FOVs). Materials and Methods: Forty extracted molar and premolar teeth were collected. Access canals were made in all teeth using a rotary system. In half of the teeth, fractures were created by the application of mild pressure with a hammer. The teeth were then randomly put into a wax rim on an acryl base designed in the shape of a mandible. CBCT scans were obtained using a Newtom 5G system with FOVs of $18cm{\times}16cm$ and $6cm{\times}6cm$. A metal pin was then placed into each tooth, and CBCT imaging was again performed using the same fields of view. All scans were evaluated by two oral and maxillofacial radiologists. The specificity, sensitivity, positive predictive value, negative predictive value, and likelihood ratios (positive and negative) were calculated. Result: The maximum levels of sensitivity and specificity (100% and 100%, respectively) were observed in small-volume CBCT scans of teeth without pins. The highest negative predictive value was found in the small-volume group without pins, whereas the positive predictive value was 100% in all groups except the large-volume group with pins. Conclusion: The specificity of CBCT decreased with the presence of a pin in the large-volume group, but not in the small-volume group.

An Analysis of Fields and Scientific Literacy Content Elements of Scientific Reports in a Popular Portal Site in Korea (국내 포탈사이트 과학 기사 분야와 과학적 소양 내용 요소 분석)

  • Lee, Myeong-Je
    • Journal of Korean Elementary Science Education
    • /
    • v.34 no.3
    • /
    • pp.338-345
    • /
    • 2015
  • The purpose of this study is to analyze science fields and content elements of the science reports in a web portal site of Republic of Korea in view of scientific literacy. The main results of the analysis on the 679 reports sampled in a year are as follows. First, 506 reports in 46 fields were identified. Reports about technology and earth science occupies 16% respectively, and life science occupies 13%, medical science 4%, chemistry, company, others 3% and physics 1%. Almost reports show technology as associate field. Second, the frequency rate of reports including scientific literacy content elements is 52%. Reports related to 'physics' and 'chemistry' as dominant fields show relatively high rate in scientific literacy elements. The element, 'social context' is included in about 96% of the reports. Both 'data and statistics' and 'application' show relatively low rate and large gaps according to dominant fields. A few concluding remarks and proposals follow from these results. First, as almost science reports show the nature of integrated science, scientific literacy acquisition through science reports in internet requires the integrated scientific view. Especially most science reports includes the contents related to technology or medical science, so the point of view in the science-technological literacy is required. Second, the scientific literacy content elements in reports show various rates according to dominant fields. Therefore, science reports need to complement the deficient content elements to carry out the role of science reports as scientific literacy sources.

Multi-view Display with Hologram Screen using Three-dimensional Bragg Diffraction

  • Okamoto, Masaaki;Shimizu, Eiji
    • Journal of Information Display
    • /
    • v.3 no.3
    • /
    • pp.1-11
    • /
    • 2002
  • Multi-view function is important to three-dimensional displays without dedicated glasses. It is the reason that the observers earnestly desire to change their positions freely. Multi-viewing is also principal to the reality of three-dimensional (3D) image displayed on the screen. The display of projection type has the advantage that the number of viewing points can be easily increased according to the number of projectors. The authors research on multi-view projection display with hologram screen. Powerful directionality of the diffracted beam from hologram screen is required unlike two-dimensional (2D) display. We developed a new method that all diffracted beams satisfied the same Bragg condition and became sufficiently bright to observe the 3D image under usual indoor light. The principle is based on the essential Bragg diffraction in the three-dimensional space. Owing to such three-dimensional Bragg diffraction we achieved an excellent hologram screen that could be multiple reconstructed in spite of single recording. This hologram screen is able to answer arbitrary numbers of viewing points within wide viewing zone. The distortion of 3D image becomes also sufficiently small with the method of dividing the cross angle between illumination and diffraction beam.

A Study on Visibility Evaluation for Cabin Type Combine (캐빈형 콤바인의 시계성 평가에 관한 연구)

  • Choi, C.H.;Kim, J.D.;Kim, T.H.;Mun, J.H.;Kim, Y.J.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.2
    • /
    • pp.120-126
    • /
    • 2009
  • The purpose of this study was to develop a visibility evaluation system for cabin type combine. Human's field of view was classified into five levels (perceptive, effective, stable gaze, induced, and auxiliary) depending on rotation of human's head and eye. Divider, reaper lever, gearshift, dashboard, and conveying part were considered as major viewpoints of combine. Visibilities of combine was evaluated quantitatively using the viewpoints and the human's field of view levels. The visibility evaluation system for cabin type combine was consisted of a laser pointer, stepping motors to control the direction of view, gyro sensors to measure horizontal and vertical angle, and I/O interface to acquire the signals. Tests were conducted with different postures ('sitting straight', 'sitting with $15^{\circ}$ tilt', 'standing straight', and 'standing with $15^{\circ}$ tilt'). The LSD (least significant difference) multiple comparison tests showed that the visibilities of viewpoints were different significantly as the operator's postures were changed. The results showed that the posture at standing with $15^{\circ}$ tilt provided the best visibility for operators. The divider of the combine was invisible due to blocking with the cabin frame at many postures. The reaper lever showed good visibilities at the postures of sitting or standing with $15^{\circ}$ tilt. The gearshift, the dashboard, and the conveying part had reasonable visibilities at the posture of sitting with $15^{\circ}$ tilt. However, most viewpoints of the combine were out of the stable gaze field of view level. Modifications of the combine design will be required to enhance the visibility during harvesting operation for farmers' safety and convenience.