• Title/Summary/Keyword: vibrator

Search Result 297, Processing Time 0.033 seconds

Audiogram in Response to Stimulation Delivered to Fluid Applied to the External Meatus

  • Geal-Dor, Miriam;Chordekar, Shai;Adelman, Cahtia;Kaufmann-Yehezkely, Michal;Sohmer, Haim
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.79-84
    • /
    • 2020
  • Background and Objectives: Hearing can be elicited in response to vibratory stimuli delivered to fluid in the external auditory meatus. To obtain a complete audiogram in subjects with normal hearing in response to pure tone vibratory stimuli delivered to fluid applied to the external meatus. Subjects and Methods: Pure tone vibratory stimuli in the audiometric range from 0.25 to 6.0 kHz were delivered to fluid applied to the external meatus of eight participants with normal hearing (15 dB or better) using a rod attached to a standard clinical bone vibrator. The fluid thresholds obtained were compared to the air conduction (AC), bone conduction (BC; mastoid), and soft tissue conduction (STC; neck) thresholds in the same subjects. Results: Fluid stimulation thresholds were obtained at every frequency in each subject. The fluid and STC (neck) audiograms sloped down at higher frequencies, while the AC and BC audiograms were flat. It is likely that the fluid stimulation audiograms did not involve AC mechanisms or even, possibly, osseous BC mechanisms. Conclusions: The thresholds elicited in response to the fluid in the meatus likely reflect a form of STC and may result from excitation of the inner ear by the vibrations induced in the fluid. The sloping fluid audiograms may reflect transmission pathways that are less effective at higher frequencies.

A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization (주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구)

  • Park, Jong-Cheol;Kim, Min-Sung
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

Development of a Thickness Mode Piezoelectric Oscillator Sensor to Detect Damages in a Structure (구조물 손상 탐지를 위한 두께 방향 모드 압전 오실레이터 센서 개발)

  • Kim, Dong-Young;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • This paper presents the feasibilityof a thickness mode piezoelectric oscillator to detect damages in structures. The thickness mode oscillator sensor is composed of an electronic feedback oscillator circuit and a piezoelectric thickness mode vibrator to be attached to a structure of interest. Damage to the structure causes a change in the impedance spectrum of the structure, which results in a corresponding change of a resonant frequency of the structure. The oscillator sensor can instantly detect the frequency change in a very simple manner. Feasibility of the piezoelectric oscillator sensor was verified with a sample aluminum plate where artificial cracks of different lengths and number were imposed in sequence. Validity of the measurement was confirmed through comparison of the experimental data with the results of finite element analyses of a plate with cracks.

A new transmission-line model for multi-layered PZT ultrasonic transducer (다층 PZT 초음파 트랜스듀서에 대한 새로운 전송선로형 등가회로의 제안)

  • Kim, Moo-Joon;Ha, Kang-Lyeol;Kim, Sung-Boo;Lee, Jong-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.29-37
    • /
    • 1995
  • A resonant frequency of piezoelectric transducer depends remarkably on the electric impedance connected to the vibrator. In this paper, using this effect of frequency controllable two layered PZT ultrasonic transducer is designed and its acoustic characteristics are analyzed by a new transmission model equivalent circuit. The theoretical and the experimental results of the electric impedance effect on the resonant frequency variation were compared and both results showed a good consistency each other. The resonant frequency has been controlled continuously in the wide frequency range of 180kHz~580kHz and the effective attenuations were less than 7dB in the frequency range of 330kHz~470kHz.

  • PDF

Comparison of static culture, micro-vibration culture, and micro-vibration culture with co-culture in poor ovarian responders

  • Hur, Yong Soo;Ryu, Eun Kyung;Yoon, San Hyun;Lim, Kyung Sil;Lee, Won Don;Lim, Jin Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.43 no.3
    • /
    • pp.146-151
    • /
    • 2016
  • Objective: This study was conducted to compare the effects of static culture, dynamic culture, and the combination of dynamic culture with specialized surfaces involving co-culture on human embryonic development. Embryos cultured using conventional static culture (SC) techniques served as a control group. We compared dynamic culture using micro-vibration culture (MVC) and micro-vibration with co-culture (MCoC), in which autologous cumulus cells were used as a specialized surface. Methods: We conducted a chart review of patients who were treated between January 2011 and November 2014 in order to compare embryonic development rates and pregnancy rates among the groups. Zygotes were cultured in micro-droplets, and embryos were subsequently selected for transfer. Some surplus embryos were cryopreserved, and the others were cultured for blastocyst development. A micro-vibrator was set at the frequency of 42 Hz for duration of 5 seconds per 60 minutes to facilitate embryo development. Results: No significant differences among the groups were present in patient's characteristics. However, the clinical pregnancy rates were significantly higher in the MVC group and the MCoC group than in the SC group. No significant differences were found in the blastocyst development rate between the SC group and the MVC group, but the blastocyst development rate in the MCoC group was significantly higher than in the SC and MVC groups. Conclusion: The clinical pregnancy rate was significantly increased by the application of micro-vibration to the embryonic cultures of poor responders. The blastocyst development rate was significantly increased by the application of MCoC to surplus embryos.

Study on the Characteristics of Cavitation Erosion-Corrosion for Mild Steel ( 1 ) - Damage Behaviour of Vibration Cavitation Erosion-Corrosion - (연강의 캐비테이션 침식-부식 특성에 관한 연구 ( 1 ) - 진동 캐비네이션 침식-부식 손상 거동 -)

  • Lim, Un-Joh;Hwang, Jae-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.413-422
    • /
    • 1995
  • Cavitation erosion-corrosion implies damage to materials due to the shock pressure or shock wave that results when bubbles form and collapse at a metal surface within a liquid. If the liquid is corrosive to the material, a condition typically encountered in industry, the component materials may suffer serious damage by a combination of mechanical and electrochemical attack. In this study, the mild steel(SS41) was tested by using the piezoelectric vibrator with 20kHz, 24$\mu$m to cavity generation apparatus. The damage behaviour of vibration cavitation erosion-corrosion and the environment characteristics were investigated in various solutions which are seawater, tap water and distilled water. The main results obtained are as follows; 1) The cavitation erosion-corrosion damage behaviour in the seawater increases to occur at the equal degree on the middle portion and the outside portion of specimen. The distilled water specimen, on other hand, occurs beginning on the outside portion across to the middle portion of specimen. 2) The cavitation erosion-corrosion damage in the tap water of low specific resistance more increases than that in the distilled water of high specific resistance at the initial testing time and more decreases than that in it by the CaCO sub(3) film with testing time. 3) Cavitation erosion-corrosion damage characteristic divides into four regions; incubation region, acceleration region, deceleration region and steady state region.

  • PDF

The Change of Ginsenoside Composition in the Ginseng (Panax ginseng) Flower Buds by the Ultrasonication and Vinegar Process

  • Gwak, Hyeon Hui;Hong, Jeong Tae;Ahn, Chang Ho;Kim, Ki Jung;Kim, Sung Gi;Yoon, Suk Soon;Im, Byung Ok;Cho, Soon Hyun;Nam, Yun Min;Ko, Sung Kwon
    • Natural Product Sciences
    • /
    • v.21 no.2
    • /
    • pp.93-97
    • /
    • 2015
  • The purpose of this study was to develop a new ginseng (Panax ginseng) flower buds extract with the high concentration of ginsenoside Rg3, Rg5, Rk1, Rh1 and F4, the Red ginseng special component. Chemical transformation from the ginseng saponin glycosides to the prosapogenin was analyzed by the HPLC. The ginseng flower buds were processed at the several treatment conditions of the ultrasonication (Oscillator 600W, Vibrator 600W) and vinegar (about 14% acidity). The result of UVGFB-480 was the butanol fraction of ginseng flower buds that had been processed with ultrasonication and vinegar for 480 minutes gained the highest amount of ginsenoside Rg5 (3.548%), Rh1 (2.037%), Rk1 (1.821%), Rg3 (1.580%) and F4 (1.535%). The ginsenoside Rg5 of UVGFB-480 was found to contain 14.3 times as high as ginseng flower buds extracts (GFB, 0.249%).

Development of Automatic Sorting System for Green pepper Using Machine Vision (기계시각에 의한 풋고추 자동 선별시스템 개발)

  • Cho, N.H.;Chang, D.I.;Lee, S.H.;Hwang, H.;Lee, Y.H.;Park, J.R.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.514-523
    • /
    • 2006
  • Production of green pepper has been increased due to customer's preference and a projected ten-year boom in the industry in Korea. This study was carried out to develop an automatic grading and sorting system for green pepper using machine vision. The system consisted of a feeding mechanism, segregation section, an image inspection chamber, image processing section, system control section, grading section, and discharging section. Green peppers were separated and transported using a bowl feeder with a vibrator and a belt conveyor, respectively. Images were taken using color CCD cameras and a color frame grabber. An on-line grading algorithm was developed using Visual C/C++. The green peppers could be graded into four classes by activating air nozzles located at the discharging section. Length and curvature of each green pepper were measured while removing a stem of it. The first derivative of thickness profile was used to remove a stem area of segmented image of the pepper. While pepper is moving at 0.45 m/s, the accuracy of grading sorting for large, medium and small pepper are 86.0%, 81.3% and 90.6% respectively. Sorting performance was 121 kg/hour, and about five times better than manual sorting. The developed system was also economically feasible to grade and sort green peppers showing the cost about 40% lower than that of manual operations.

Effective of Change Obesity Index by Specific Posture Exercise Using the Vibrator (진동기기를 이용한 자세별 운동이 비만에 미치는 영향)

  • Kim, Myung-Chul;Lee, Woo-Chul;Han, Seul-Ki
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.5
    • /
    • pp.757-762
    • /
    • 2013
  • The purpose of this study is to compare and evaluate the change of Body Mass Index(BMI) and body composition after having performed vibration exercise equipment at different ground conditions. The subjects were divided into 4 groups; Standing Group(SG)(n=10) and Horseback riding Group(BG)(n=10), Four point kneeling Group(FG)(n=10), Complex position Group(CG)(n=11). The period of intervention was for four weeks. Such as BMI and Waist Hip Ratio(WHR), Body Fat Ratio(BFR) were measured before and after exercise. The results from the above three measurements, only the CG showed significant differences. We were able to confirm that obesity change through complex position combines vibration exercise.

A Study on the ELID Grinding Properties of Single Crystal Sapphire Wafer using Ultrasonic Table (초음파 테이블을 이용한 단결정 사파이어 웨이퍼의 ELID 연삭가공 특성 연구)

  • Hwang, JinHa;Kwak, Tae-Soo;Lee, Deug-Woo;Jung, Myung-Won;Lee, Sang-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.75-80
    • /
    • 2013
  • Single crystal sapphire being used in high technology industry is a brittle material with a high hardness and excellent physical properties. ELID(Electrolytic In-Process Dressing) grinding technology was applied to material removal machining process of single crystal sapphire wafer. Ultrasonic vibration which added to material using ultrasonic table was adopted to efficient ELID grinding of sapphire materials. The evaluation of the ground surface of single crystal sapphire wafer was carried out by means of surface measuring by using AFM(Atomic Force Microscope), surface roughness tester and optical microscope device. As the results of experiment, it was shown that more efficient grinding was conducted when using ultrasonic table. In case of using #170 grinding wheel, surface roughness of ELID ground specimen in using ultrasonic table was superior to ELID ground specimen without ultrasonic table. However, In case of using #2000 grinding wheel, surface roughness of ELID ground specimen in using ultrasonic table was inferior to ELID ground specimen without ultrasonic table.