• 제목/요약/키워드: vibration velocity

검색결과 1,398건 처리시간 0.028초

The effect of blast-induced vibration on the stability of underground water-sealed gas storage caverns

  • Zhou, Yuchun;Wu, Li;Li, Jialong;Yuan, Qing
    • Geosystem Engineering
    • /
    • 제21권6호
    • /
    • pp.326-334
    • /
    • 2018
  • Underground water-sealed gas storage caverns have become the primary method for strategic storage of LPG. Previous studies of excavation blasting effects on large-scale underground water-sealed gas storage caverns are rare at home and abroad. In this paper, the blasting excavation for underground water-sealed propane storage caverns in Yantai was introduced and field tests of blasting vibration were carried out. Field test data showed that the horizontal radial velocity had a major controlling effect in the blasting vibration and frequencies would not cause the vibration velocity concentration effects. In terms of the influence of blasting vibration on adjacent caverns, the dynamic finite element model in LS-DYNA soft was established, whose reliability was verified by field test data. The numerical results indicated the near-blasting side was primary zone for the structural failure and tensile failure tended to occur in the middle of the curved wall on the near-blasting side. Meanwhile, the safety criterions for adjacent caverns based on stress wave theory and according to statistic relationship between peak effective tensile stress and peak particle velocities were obtained, respectively. Finally, with Safety Regulations for Blasting in China (GB6722-2014) taken into account, a final safety criterion was proposed.

보의 진동제어를 위한 압전 액추에이터의 길이변화 효과 연구 (Effect of Piezoactuator Length Variation for Vibration Control of Beams)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.442-448
    • /
    • 2008
  • This paper presents an approach to define an optimal piezoactuator length to actively control structural vibration. The optimal ratio of the piezoactuator length against beam length when a pair of piezoceramic actuator and accelerometer is used to suppress unwanted vibration with direct velocity feedback (DVFB) control strategy is not clearly defined so far. It is well known that direct velocity feedback (DVFB) control can be very useful when a pair of sensor and actuator is collocated on structures with a high gain and excellent stability. It is considered that three different collocated pairs of piezoelectric actuators (20, 50 and 100 mm) and accelerometers installed on three identical clamped-clamped beams (300 * 20 * 1 mm). The response of each sensor-actuator pair requires strictly positive real (SPR) property to apply a high feedback gain. However the length of the piezoactuator affects SPR property of the sensor-actuator response. Intensive simulation and experiment shows the effect of the actuator length variation is strongly related with the frequency range of SPR property. A shorter actuator gave a wider SPR frequency range as a longer one had a narrower range. The shorter actuator showed limited control performance in spite of a higher gain was applied because the actuation force was relatively small. Thus an optimal length ratio (actuator length/beam length) was suggested to obtain relevant performance with good stability with DVFB strategy. The result of this investigation could give important information in the design of active control system to suppress unwanted vibration of smart structures with piezoelectric actuators and accelerometers.

  • PDF

발파 소음.진동 수준의 변환 연구 (A study on the transformation of blasting noise and vibration level)

  • 김남수;양형식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.377-380
    • /
    • 1998
  • Basting vibration and air blast were measured by particle velocity and overpressure as well as environmental unit, dB(V) and dB(A). Variables for vibration and noise show good relationship and proportional equations are suggested. But there are some variations, and it means that predictions by design variables are not valid for human damage estimation or limit application of regulations.

  • PDF

양생초기의 진동시간 제어에 따른 콘크리트의 강도 변화 (Variation of Concrete Strength according to Vibration Time Control for Fresh Concrete)

  • 송규황;김종수;김명식;장희석;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.675-678
    • /
    • 2003
  • Experimental results for variation of concrete strength according to vibration time control for fresh concrete were given. Vibration velocity, time before vibration and vibrating time were used as experimental parameters. Compressive strength, split tensile strength, ana bond strength were investigated and then fracture surfaces of split tensile strength specimen were observed. From the experimental results, it could be concluded that there may be no decrease in concrete strengths if time before vibration will be sustained at least for more than 3 hours.

  • PDF

The Experiment of Flow Induced Vibration in PWR RCCAs

  • Kim, Sang-Nyung;Cheol Shin
    • Journal of Mechanical Science and Technology
    • /
    • 제15권3호
    • /
    • pp.291-299
    • /
    • 2001
  • Recently, severe wear on the shutdown rod cladding of Ulchin Nuclear Power Plant #1, #2 were observed by the Eddy Current Test(E.C.T.). In particular, the wear at the sixth card location was up to 75%. The test results indicated that the Flow Induced Vibration(F.I.V.) might be the cause of the fretting wear resulting from the contact between Rod Cluster Control Assemblies(RCCAs) and their spacing cards(guide plates) arranged in the guide tube. From reviewing RCCAs fretting wear repots and analyzing the general characteristics of F.I.V. mechanism in the reactor, geometric layout and flow conditions around the control rod, it is concluded that the turbulence excitation is the most probable vibration mechanism of RCCA. To identify the governing mechanism of RCCA vibration, an experiment was performed for a representative rod position in which the most serious fretting wear experienced among the six rod positions. The experimental rig was designed and set up to satisfy the governing nondimensional numbers which are Reynolds number and mass damping parameter. The vibration amplitude measurement by the non-contact laser displacement sensor showed good agreements in the frequency and the maximum wearing(vibration) location with Ulchin E.C.T. results and Framatome report, respectively. The sudden increase in the vibration amplitude was sensed around the 6th guide plate with mass flow rate variation. Comparing the similitude rod behaviour with the idealized response of a cylinder in flow induced vibration, it was found that he dominant mechanism of vibration was transferred from turbulence excitation to periodic shedding at the mass flow ate 90ι/min. Also the critical velocity of the vibration in RCCAs was determined and the vibration can be prevented by reducing the bypass flow rate below the critical velocity.

  • PDF

건공화 공법의 발파 성능 평가를 위한 현장 시험에 관한 연구 (A Study of a Pilot Test for a Blasting Performance Evaluation Using a Dry Hole Charged with ANFO)

  • 이승훈;정성훈;최형빈
    • 대한토목학회논문집
    • /
    • 제42권2호
    • /
    • pp.197-208
    • /
    • 2022
  • 암반층이 얕은 깊이에서 출현하는 국내 지층 조건과 지하 공간의 활용도 증가로 인해서, 발파에 의한 굴착은 여전히 이용되고 있다. 발파 천공 이후에 존재하는 물이 있는 조건에서 실시되는 표준 발파는 폭굉압력 감소, 일정 장약량 사용, 디커플링과 같은 기술적인 어려움이 있다. 하지만, 기존의 표준 발파 공법을 대체할 만한 공법이 없는 실정이다. 본 논문에서는 건공화 펌프 시스템을 이용하여, 천공 내부에 존재하는 물을 제거하는 건공화 ANFO (Ammonium Nitrate Fuel Oil) 발파와 발파 성능의 비교를 위해서 추가적으로 표준 발파를 수행하였다. 각각의 발파 공법에서 계측된 진동 속도 데이터들과 환산거리의 함수로 이루어진 경험적인 발파진동 추정식을 이용하여, 최소제곱법에 의한 선형회귀분석을 실시하고, 궁극적으로 발파 성능을 정량적으로 분석하였다. 그 결과, 건공화 ANFO 발파에서 진동 감쇠가 더 크게 발생하고, 암반 파쇄에 더 많은 에너지를 소비하여, 더 가까운 거리에서 진동 허용 기준을 만족하는 진동 속도를 보였다. 또한, 표준 발파의 발파 진동 영향권이 건공화 ANFO 발파보다 더 멀리 있고, 발파 패턴의 범위가 더 넓은 것으로 나타났다. 본 연구에서 수행된 현장 발파 실험 결과로부터, 건공화 ANFO 발파 공법의 발파 성능이 효율적임을 확인하였다.

입자 영상 유속계를 이용한 초음파 수직진동에 의해 유도된 공진상태에서의 음향유동에 관한 연구 (Study of Acoustic Streaming at Resonance by Longitudinal Ultrasonic Vibration Using Particle Imaging Velocimetry)

  • 노병국;이동렬
    • 한국음향학회지
    • /
    • 제23권5호
    • /
    • pp.340-352
    • /
    • 2004
  • 28.5 ㎑의 초음파의 미세 수직진동에 의해서 유도된 음향유동 (acoustic streaming)을 레이저를 이용한 입자 영상. 유속계에 의하여 고정 유리 평판과 초음파 진동자의 사이에서의 공기 유동을 가시화 하였다. 음향유동에 의한 공기의 유동 속도의 증가를 측정하기 위해 고정 유리 평판과 초음파 진동자의 사이에서의 속도변화를 실시간으로 측정하였다. 진동자와 고정 평판의 사이의 gap에 따른 음향유동의 세기의 변화를 정량적인 공기의 유동 속도의 변화에 의해 관찰되었고 고정판과 초음파 진동자 사이의 gap에서 공진 상태를 야기시키는 공진 Gap (H=18, 24, 30, 36㎜)중에서 공진 Gap (H)이 18m일 때 최대의 음향속도가 존재함을 알 수 있었고 진동자 표면부근에서부터 고정평판사이까지의 국소 최대 난류강도의 축 방향 위치에 따른 변화는 gap의 크기에 따라 8%∼70% 이었다. 전단응력값은 반경방향 위치의 중심영역에서 최대전단응력을 가지며 와도 분포도 반경방향 위치에서 진동자 중심영역에 최대 및 최소와도 값을 가짐을 알 수 있었다.

비동위치화된 센서와 액추에이터를 이용한 외팔보의 끝단 진동에 대한 직접속도 피드백제어 (Direct Velocity Feedback for Tip Vibration Control of a Cantilever Beam with a Non-collocated Sensor and Actuator Pair)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.109-114
    • /
    • 2004
  • This paper presents a theoretical and experimental study of a non-collocated pair of piezopolymer PVDF sensor and piezoceramic PZT actuator, which are bonded on a cantilever beam, in order to suppress unwanted vibration at the tip of the beam. The PZT actuator patch was bonded near the clamped part and the PVDF sensor, which was triangularly shaped, was bonded on the other part of the beam. This is because the triangular PVDF sensor is known that it can detect the tip velocity of a cantilever beam. Because the arrangement of the sensor and actuator pair is not collocated and overlapped each other, the pair can avoid so called 'the in-plane coupling'. The test beam is made of aluminum with the dimension of $200\times20\times2mm$, and the two PZT5H actuators are both $20\times20\times1mm$ and bonded on the beam out-of-phase, and the PVDF sensor is $178mm\times6mm\times52{\mu}m$. Before control, the sensor-actuator frequency response function is confirmed to have a nice phase response without accumulation in a reasonable frequency range of up to 5000 Hz. Both the DVFB and displacement feedback strategies made the error signal from the tip velocity (or displacement) sensor is transmitted to a power amplifier to operate the PZT actuator (secondary source). Both the control methods attenuate the magnitude of the first two resonances in the error spectrum of about 6-7 dB.

  • PDF

진동이 경량기포토의 특성에 미치는 영향 (Effect of Vibration on Characteristics of Lightweight Air-Trapped Soil)

  • 이영준;김성원;박이근;김태형
    • 한국지반환경공학회 논문집
    • /
    • 제12권4호
    • /
    • pp.5-15
    • /
    • 2011
  • 본 논문에서는 진동이 경량기포토의 양생과 압축강도에 미치는 영향을 파악하기 위해 이루어졌다. 경량기포토가 기존 구조물에 인접해서 시공 시 진동의 영향을 받는 경우가 종종 발생되고 있다. 예를 들어, 파일 항타, 발파 및 장비의 공용 등이 있으며, 교통난 해소를 위한 도로 확폭 공사를 하고 있는 경우 기존 도로상의 차량진행으로 인한 진동도 경량기포토의 품질저하에 영향을 미칠 것으로 예상된다. 특히 경량기포토는 수많은 기포가 포함되어있고 양생에 따른 시간이 필요하기 때문에, 그 영향은 예상되는 것보다 훨씬 더 클 것이라고 판단된다. 하지만 현재 국내에서 진동이 미치는 영향에 관한 연구는 주로 일반콘크리트에 대해 많이 이루어지고 있고, 경량기포토에 대한 진동영향연구는 미흡한 실정이다. 따라서 본 논문에서는 진동이 양생중인 경량기포토에 미치는 영향을 평가하기 위하여 실험변수를 진동속도(vibration velocity), 진동가력시점(time when vibrated), 배합비(mixing ratio) 등으로 나누어 경량기포토의 일축압축강도 등을 시험하였다. 시험의 결과는 경량기포토의 특성에 대한 진동의 영향을 명확히 밝힐 수 있었다.

마찰을 고려한 이중 오프셋 등속조인트의 축력 해석에 관한 연구 (Analytic Study on the Axial Forces of a Double Offset Constant Velocity Joints in Consideration of Friction Effect)

  • 배병철
    • 한국자동차공학회논문집
    • /
    • 제16권2호
    • /
    • pp.120-127
    • /
    • 2008
  • The constant velocity joint(CVJ) used for transmitting torque to the front wheels is an important part in automotive drive system. There are several types of constant velocity joints. Typically, they are classified by fixed and plunging constant velocity joints. The axial force generated in plunging constant velocity joints influences significantly the noise, vibration and harshness. For heaps of time, many constant velocity joint markers have been studying and developing a valid method to reduce the axial force and extensive tests have been carried out on rigs. This paper presents the analysis method to predict the axial force of a double offset constant velocity joint(DOJ), a kind of plunging constant velocity joint, and the influence of ball-cage dimension tolerance on the axial force.