• 제목/요약/키워드: vertical structure

검색결과 2,424건 처리시간 0.025초

노후 경사주거지 쇠퇴지표로서의 유휴공간 발생패턴 연구 (A Study on the Occurrence Pattern of Vacant Spaces as the Decline Index in Old Hillside Residential Area)

  • 정인아;우신구
    • 대한건축학회논문집:계획계
    • /
    • 제34권3호
    • /
    • pp.93-104
    • /
    • 2018
  • This study is about occurrence pattern of vacant spaces as a urban decline indicator to consider a decline of old hillside residential area from spatial structure perspective. For investigation based upon vacant space and the street structure, this study selects Ami Chojang-dong in Seo-gu, Busan, of which 79.7% of total area is over a gradient of $10^{\circ}$. Focused on relationship between occurrence pattern of vacant spaces and 'vertical alleys(link)' serving as main movement path of local residents in hillside residential area, the length, numbers, slopes, and use characteristic of vertical alleys were analyzed using Arc GIS 9.3 program to classify characteristic zone types of spacial structure in hillside residential area. After the occurrence pattern of vacant space are interpreted in relation with building density, vertical alleys' number length slope, the social and economic issues have been considered as well. After analyzing the occurrence pattern of vacant space, this study argues that the occurrence pattern of vacant space in old hillside residential area is rather affected by street structure system consisting of vertical alleys than the impacts of social economical issues.

지하철 진동에 의한 건축구조물의 진동특성 (Dynamic Response of Building Structures Induced by Subway Operation)

  • 김희철;이동근;민경원
    • 전산구조공학
    • /
    • 제8권1호
    • /
    • pp.95-106
    • /
    • 1995
  • 지하철의 운행에 의한 소음과 진동은 운행로 주위의 주민을 괴롭히는 중요한 요소의 하나이다. 일반적인 건물의 진동은 횡방향의 진동을 많이 고려하고 있으나 지하철의 운행에 의한 건물의 진동은 수직방향의 진동을 주요하게 다루어야 한다. 수직방향의 진동을 고려하기 위한 구조물은 보의 진동이 고려된 모델이어야 한다. 따라서 구조물의 수평방향 진동을 고려하기 위하여 사용된 모델은 수직방향의 진동을 고려하기 위한 모델과 같이 사용될 수 없다. 건물의 수직진동을 고려한 해석을 수행하기 위해서는 보의 관성력을 충분히 고려할 수 있는 모델이 사용되어야 한다. 본 논문에서는 지하철의 운행에 의한 구조물의 수직방향진동을 고려하기 위한 구조물의 해석 모델기법에 대하여 연구한 결과 기둥의 경우 하나이상 보의 경우 두개 이상의 요소로 나누어 해석하는 것이 바람직한 것으로 나타났다.

  • PDF

High-transmittance Multi-domain Vertical Alignment Liquid Crystal Device with Protrusion Structure

  • Kim, Ki-Han;Jeon, Eun-Young;Park, Byung Wok;Choi, Sun-Wook;Song, Dong Han;Kim, Hoon;Shin, Ki-Chul;Kim, Hee Seop;Yoon, Tae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.166-169
    • /
    • 2012
  • We propose a high-transmittance multi-domain vertical alignment liquid crystal device with a protrusion structure. Disclination lines, which inevitably appear at the boundaries of domains in a multi-domain structure, can be reduced by adding a protrusion structure on the top substrate. The transmittance was improved by 11% using the proposed structure with no change of either the dark state or the operating voltage.

Evaluation of dynamic behaviors of gravity-based structures under seismic load considering fluid-structure-ground interactions

  • Hyo-Jin Kim;Sunghun Jung;Seongpil Cho
    • Structural Engineering and Mechanics
    • /
    • 제88권3호
    • /
    • pp.251-262
    • /
    • 2023
  • This paper presents a method for assessing the dynamic responses of gravity-based structures (GBS) under various seismic loads, with a focus on fluid-structure-ground interactions. Models of GBSs and their surrounding environments were developed, incorporating interaction effects among the structure, seawater, and seabed. Dynamic responses of the GBS subjected to three seismic loads-Chi-Chi, Northridge01, and Northridge02-were calculated, with consideration of both horizontal and vertical accelerations, as well as displacements. Parametric studies indicated that the primary factors affecting the dynamic responses of GBS were seismic loads characterized by significant input forces and accelerations. The frictional force on the ground had minimal impact on the horizontal and vertical displacements of the GBS. Weight emerged as a critical factor in anchoring the GBS to the ground and minimizing vertical accelerations and displacements.

인공용승구조물 설치에 의한 유동변화(II) (Variation of Current by the Building of Artificial Upwelling Structure(II))

  • 황석범;김동선;배상완
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2007년도 추계학술발표회
    • /
    • pp.9-14
    • /
    • 2007
  • 한국 남해안 거제도 앞바다에 구축된 인공용승구조물로 인하여 발생하는 유동 변화를 파악하기 위해 ADCP(Acoustic Doppler Current Profiler)를 이용한 정선관측을 2003년 하계 및 추계에 실시하였다. 관측 결과 하계에는 수심 약 $30{\sim}40$ m를 기준으로 상층과 하층의 유동분포가 상이한 경계수심이 존재하였으며, 추계에는 이러한 현상이 3층 구조로 나타났다. 또한 연직유동성분은 수심과 지역에 따라 상승류와 하강류가 번갈아 분포하였으며 이러한 현상은 관측범위를 확장하였을 때도 유사한 유동분포를 보이고 있다. 한편 ADCP의 수평유동성분을 이용하여 계산된 연직전단(vertical shear) 및 상대와도(relative vorticity)는 상승류가 발생하는 지역에서 연직전단은 큰 값을 나타내었고, 상대와도는 +값으로 상승류의 방향을 나타내었다. 이러한 결과는 유동성분의 상승류 분포역과 유사하게 나타났다.

  • PDF

Fundamental period of infilled RC frame structures with vertical irregularity

  • Asteris, Panagiotis G.;Repapis, Constantinos C.;Foskolos, Filippos;Fotos, Alkis;Tsaris, Athanasios K.
    • Structural Engineering and Mechanics
    • /
    • 제61권5호
    • /
    • pp.663-674
    • /
    • 2017
  • The determination of the fundamental period of vibration of a structure is essential to earthquake design. Current codes provide formulas for the approximate estimation of the fundamental period of earthquake-resistant building systems. These formulas are dependent only on the height of the structure or number of storeys without taking into account the presence of infill walls into the structure, despite the fact that infill walls increase the stiffness and mass of the structure leading to significant changes in the fundamental period. Furthermore, such a formulation is overly conservative and unable to account for structures with geometric irregularities. In this study, which comprises the companion paper of previous published research by the authors, the effect of the vertical geometric irregularities on the fundamental periods of masonry infilled structures has been investigated, through a large set of infilled frame structure cases. Based on these results, an attempt to quantify the reduction of the fundamental period due to the vertical geometric irregularities has been made through a proposal of properly reduction factor.

조선시대 민가 오량가(五樑架) 종단구성의 규모와 부재치수에 관한 연구 (A Study on the Scale and Dimensions of member of Sectional structure for Five-Purlin Houses from Joseon Era)

  • 김재웅
    • 건축역사연구
    • /
    • 제28권1호
    • /
    • pp.7-16
    • /
    • 2019
  • As a part of the research on existing structures of private homes from Joseon Era. Focusing on one hundred twenty five-purlin houses, the current study investigated the features and characteristics of the house structure from style, size, proportion and roof pitch, and measurements of key parts, and developed the following conclusions. Most are single-houses (89, 83%), and among them, there are 47 single front-terrace houses (39%), which is the highest number. The sizes of lower house structure do not differ greatly depending on the vertical structure, and single rear terrace house and double-house have relatively larger side sizes. The size of upper structure is larger in double-houses compared to other vertical structures, indicating a relatively higher roof. The cross-section measurement of major parts show that double-houses are larger than single-houses by 3cm in pillar, 3-4.5cm in crossbeam length, and 4.5cm in crossbeam width. However, Janghyeo width was consistent at 7.5 to 10.5cm, maintaining uniformity regardless of vertical structure of the houses. In addition, the cross-section measurements decreased from sixteenth to nineteenth century, with the size of pillar size decreasing the most. The result that the Janghyeo width is not related to the house structure house confirmed that the Janghyeo width was kept consistent regardless of the size of the house structure.

공기로 지지되는 수직 아치의 구조거동에 관한 연구 (A study on the structural behaviors of air-pressurized vertical arch)

  • 김재열;이장복;권택진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.274-279
    • /
    • 1998
  • The structural behaviors of a arch composed of flexible membrane are investigated. The membrane is considered as thin shell with internal pressure during FEM analysis by using ABAQUS. In the paper, a wind load and uniformly distributed vertical load are considered. As a vertical load, snow loads including applied over all and half of the structure are introduced. The ends of arch are fixed to the ground. Load-Deflections relationship, buckling mode of the structure are presented.

  • PDF

IBS electrode structure for enhanced performance in ac PDP

  • Yang, Seung-Hee;Moon, Jae-Seung;Kim, Kwang-Nyun;Moon, Cheol-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.589-592
    • /
    • 2007
  • In this paper, we propose IBS(ITO-BUS Separated) electrode structure. BUS electrode lines are placed apart from the ITO electrode lines, and they are electrically connected with vertical auxiliary electrodes. We varied the lengths of the vertical electrodes as 70, 120, 320um. The highest luminous efficiency and the largest IR emission peak were obtained for 70um length.

  • PDF

Fabrication of Micromirror Array with Vertical Spring Structure

  • 신종우;김용권;최범규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.416-418
    • /
    • 1996
  • A $50{\times}50{\mu}m^2$ aluminum micromirror array is fabricated using surface micromachining technology. $50{\times}50$ micromirrors are arrayed two dimensionally. The micromirror plate is supported by a vertical spring structure that is placed underneath the mirror plate. When the mirror plates reflect a light, the micromirror array un have large effective reflecting area. Fabrication of vertical spring uses only one mask and shadow evaporation process.

  • PDF