• Title/Summary/Keyword: variable conversion gain

Search Result 22, Processing Time 0.03 seconds

A Wide Voltage-Gain Range Asymmetric H-Bridge Bidirectional DC-DC Converter with a Common Ground for Energy Storage Systems

  • Zhang, Yun;Gao, Yongping;Li, Jing;Sumner, Mark
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.343-355
    • /
    • 2018
  • A wide-voltage-conversion range bidirectional DC-DC converter is proposed in this paper. The topology is comprised of one typical LC energy storage component and a special common grounded asymmetric H-bridge with four active power switches/anti-parallel diodes. The narrow output PWM voltage is generated from the voltage difference between two normal (wider) output PWM voltages from the asymmetric H-bridge with duty cycles close to 0.5. The equivalent switching frequency of the output PWM voltage is double the actual switching frequency, and a wide step-down/step-up ratio range is achieved. A 300W prototype has been constructed to validate the feasibility and effectiveness of the proposed bidirectional converter between the variable low voltage side (24V~48V) and the constant high voltage side (200V). The slave active power switches allow ZVS turn-on and turn-off without requiring any extra hardware. The maximum conversion efficiency is 94.7% in the step-down mode and 93.5% in the step-up mode. Therefore, the proposed bidirectional topology with a common ground is suitable for energy storage systems such as renewable power generation systems and electric vehicles with a hybrid energy source.

A 3.1 to 5 GHz CMOS Transceiver for DS-UWB Systems

  • Park, Bong-Hyuk;Lee, Kyung-Ai;Hong, Song-Cheol;Choi, Sang-Sung
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.421-429
    • /
    • 2007
  • This paper presents a direct-conversion CMOS transceiver for fully digital DS-UWB systems. The transceiver includes all of the radio building blocks, such as a T/R switch, a low noise amplifier, an I/Q demodulator, a low pass filter, a variable gain amplifier as a receiver, the same receiver blocks as a transmitter including a phase-locked loop (PLL), and a voltage controlled oscillator (VCO). A single-ended-to-differential converter is implemented in the down-conversion mixer and a differential-to-single-ended converter is implemented in the driver amplifier stage. The chip is fabricated on a 9.0 $mm^2$ die using standard 0.18 ${\mu}m$ CMOS technology and a 64-pin MicroLead Frame package. Experimental results show the total current consumption is 143 mA including the PLL and VCO. The chip has a 3.5 dB receiver gain flatness at the 660 MHz bandwidth. These results indicate that the architecture and circuits are adaptable to the implementation of a wideband, low-power, and high-speed wireless personal area network.

  • PDF

ECONOMIC BENEFITS OF SUPPLEMENTING LAMBS WITH UREA MOLASSES BLOCKS ON RANGES OF PAKISTAN

  • Rafiq, M.;Jadoon, J.K.;Mahmood, K.;Naqvi, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.9 no.2
    • /
    • pp.127-132
    • /
    • 1996
  • Effects on feed intake, liveweight gain and economic benefits of supplementing lambs with urea molasses blocks, were studied. Forty eight crossbred lambs were divided into 6 groups and assigned randomly to grazing on native pasture (CONT) or along with supplements of Commercial ration (COM) and urea molasses blocks (UMBs) containing two levels of cement and calcium oxide as a binding agent. Analysis of variance revealed highly significant (p<0.01) differences in dry matter (DMI, g/day), crude protein (CPI, g/day) and metabolizable energy (MEI, MJ/day) intakes. Differences in liveweight gain (LWG, g/day), feed conversion ratio (FCR) and net economic benefit of supplementation were also highly variable. The intake of DM, CP and ME varied from 974 to 1002, 66-70 and 7.6-8.4 in lambs supplemented with UMBs, significantly (p<0.01) greater than 848, 52.5 and 5.6 in lambs supplemented with COM or FCR and net economic benefits (54.3; 57.8; 17.1 and 1.96; 2.4) in lambs supplemented with COM and UMB-2, were CONT or supplemented with UMB-1, UMB-3 and UMB-4 respectively. Factors responsible for differences in feed intake, liveweight gain and economic benefits, are discussed.

A 8-bit Variable Gain Single-slope ADC for CMOS Image Sensor

  • Park, Soo-Yang;Son, Sang-Hee;Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.38-45
    • /
    • 2007
  • A new 8-bit single-slope ADC using analog RAMP generator with digitally controllable dynamic range has been proposed and simulated for column level or per-pixel CMOS image sensor application. The conversion gain of ADC can he controlled easily by using frequency divider with digitally controllable diviber ratio, coarse/fine RAMP with class-AB op-amp, resistor strings, decoder, comparator, and etc. The chip area and power consumption can be decreased by simplified analog circuits and passive components. Proposed frequency divider has been implemented and verified with 0.65um, 2-poly, 2-metal standard CMOS process. And the functional verification has been simulated and accomplished in a 0.35$\mu$m standard CMOS process.

  • PDF

Sensorless Control of Non-salient Permanent Magnet Synchronous Motor Drives using Rotor Position Tracking PI Controller

  • Lee Jong-Kun;Seok Jul-Ki
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.189-195
    • /
    • 2005
  • This paper presents a new velocity estimation strategy for a non-salient permanent magnet synchronous motor drive without high frequency signal injection or special PWM pattern. This approach is based on the d-axis current regulator output voltage of the drive system, which contains the rotor position error information. The rotor velocity can be estimated through a rotor position tracking PI controller that controls the position error at zero. For zero and low speed operation, the PI gain of the rotor position tracking controller has a variable structure according to the estimated rotor velocity. Then, at zero speed, the rotor position and velocity have sluggish dynamics because the varying gains are very low in this region. In order to boost the bandwidth of the PI controller during zero speed, the loop recovery technique is applied to the control system. The PI tuning formulas are also derived by analyzing this control system by frequency domain specifications such as phase margin and bandwidth assignment.

The Design of CMOS Multi-mode/Multi-band Wireless Receiver

  • Hwang, Bo-Hyeon;Jeong, Jae-Hun;Yu, Chang-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.615-616
    • /
    • 2006
  • Nowadays, the need of multi-mode/multi-band transceiver is rapidly increasing, so we design a direct conversion RF front-end for multi-mode/multi-band receiver that support WCDMA/CDMA2000/WIBRO standard. It consists of variable gain reconfigurable LNA and single input double balanced Mixer and complementary differential LC Oscillator. The circuit is implemented in 0.18 um RF CMOS technology and is suitable for low-cost mode/multi-band.

  • PDF

Effects of Various Sources and Levels of Chromium on Performance of Broilers

  • Suksombat, Wisitiporn;Kanchanatawee, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.11
    • /
    • pp.1628-1633
    • /
    • 2005
  • Three hundred and twenty four one day old mixed sex broiler chicks were assigned at random into 9 treatment groups. The experimental design was a 3${\times}$3 factorial arrangement. During the starter period (week 1-3), chicks were fed ad libitum. A cornsoybean meal based diet contained 23% crude protein, 3,200 kcal/kg metabolizable energy (NRC, 1994), and supplemented with organic or inorganic forms of chromium. Two organic chromium products, chromium yeast (Cr-Yeast from Alltech Biotechnology Corporation Limited) and chromium picolinate (Cr-Pic) were supplemented at the rate of 200, 400 and 800 ppb. One inorganic product, chromium chloride, was supplemented at the rate of 200, 400 and 800 ppb. During the finishing period (week 4-7), the corn-soybean meal based diet contained 20% crude protein, 3,200 kcal/kg metabolizable energy (NRC, 1994), and the same levels of chromium as in the starter period were added. No significant difference was observed among treatment groups in average daily gain, feed intake, body weight gain, feed conversion ratio and mortality. The carcass percentage of broilers receiving 200 and 400 ppb organic chromium (Cr-Yeast or Cr-Pic) was significantly increased (p<0.01). In addition, the supplementation of organic chromium reduced (p<0.05) breast meat fat content but increased breast meat protein content. The addition of chromium in the diet had no effect on boneless breast, skinless boneless breast, boneless leg, skinless boneless leg but reduced percentage of sirloin muscle. Total cholesterol and triglycerides were reduced by organic Cr supplementation. Supplementation with 200 and 400 ppb of both Cr-Yeast and Cr-Pic showed the lowest total cholesterol. The effects of type of Cr on HDL and LDL were variable, however, LDL increased with increasing level of Cr supplementation. This trial indicates that organic chromium tended to improve growth performances and carcass composition, reduced total cholesterol and triglycerides. The optimum level of organic chromium supplementation was at 200 ppb.

A Signal Readout System for CNT Sensor Arrays (CNT 센서 어레이를 위한 신호 검출 시스템)

  • Shin, Young-San;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.31-39
    • /
    • 2011
  • In this paper, we propose a signal readout system with small area and low power consumption for CNT sensor arrays. The proposed system consists of signal readout circuitry, a digital controller, and UART I/O. The key components of the signal readout circuitry are 64 transimpedance amplifiers (TIA) and SAR-ADC with 11-bit resolution. The TIA adopts an active input current mirror (AICM) for voltage biasing and current amplification of a sensor. The proposed architecture can reduce area and power without sampling rate degradation because the 64 TIAs share a variable gain amplifier (VGA) which needs large area and high power due to resistive feedback. In addition, the SAR-ADC is designed for low power with modified algorithm where the operation of the lower bits can be skipped according to an input voltage level. The operation of ADC is controlled by a digital controller based on UART protocol. The data of ADC can be monitored on a computer terminal. The signal readout circuitry was designed with 0.13${\mu}m$ CMOS technology. It occupies the area of 0.173 $mm^2$ and consumes 77.06${\mu}W$ at the conversion rate of 640 samples/s. According to measurement, the linearity error is under 5.3% in the input sensing current range of 10nA - 10${\mu}A$. The UART I/O and the digital controller were designed with 0.18${\mu}m$ CMOS technology and their area is 0.251 $mm^2$.

Effects of Replacing Soybean Meal with Fermented Rapeseed Meal on Performance, Serum Biochemical Variables and Intestinal Morphology of Broilers

  • Xu, F.Z.;Zeng, X.G.;Ding, X.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.12
    • /
    • pp.1734-1741
    • /
    • 2012
  • This trial was performed to study the effects of replacing soybean meal (SBM) with fermented rapeseed meal (RSM) on growth performance, serum biochemistry variable and intestinal morphology of broilers. A total of 640 d-old Arbor Acres broiler chicks were randomly allocated to 4 dietary treatments, 4 pens per treatment and 40 birds per pen for a 6-wk feeding trial. In the four treatment groups, fermented RSM replaced soybean meal at 0, 5, 10, and 15%, respectively. On 21 d and 42 d, two birds from each pen were randomly selected and slaughtered. Blood samples and sections of duodenum, jejunum, and ileum were collected for measurement of serum biochemical variables and intestinal morphology, respectively. Results showed that body weight gain (BWG) and feed conversion (FC) were significantly (p<0.01) poorer for birds fed the 15% fermented RSM diet than those fed with 0, 5 and 10% fermented RSM diets during all periods. Compared with 0 and 5% fermented RSM groups, IgG content in the serum of birds in 10 and 15% fermented RSM groups was improved (p<0.01) urea nitrogen content of serum was reduced (p<0.01) during both growing and finishing periods. However, IgM, phosphorus and calcium levels increased (p<0.05) only during the growing period. Increased (p<0.05) villus height was observed in the duodenum and jejunum of broilers fed the diet with 10% fermented RSM. In addition, villus height to crypt depth ratio in the jejunum was significantly higher (p<0.01) for birds fed the diet with 10% fermented RSM than for those fed diets with 0, 5 and 15% fermented RSM. The present results suggest that RSM fermented with Lactobacillus fermentum and Bacillus subtilis is a promising alternative protein source and that it could be safely used replace up to 10% SBM in broiler diets.

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF