• Title/Summary/Keyword: value measurement

Search Result 4,742, Processing Time 0.03 seconds

A Study on Measurement Uncertainty of Insensitive Munitions Tests (둔감탄약 시험의 측정불확도 산출 방안 연구)

  • Kim, Min;Kim, Jong-Myoung;Yang, Seung-Ho;Sun, Tae-Boo
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.533-547
    • /
    • 2017
  • Purpose: This study proposes the main sources of uncertainty and uncertainty analysis of a measurement system of insensitive munitions tests. Methods: We established the mathematical model for calculating measurement uncertainty of insensitive munitions tests, conducted experiments for calculating uncertainties of dynamic sensitivity and overshoot value, and estimated the distributions of uncertainty factors. Results: The measurement uncertainty calculation methods are presented, which include experimental data processing methods for calculating uncertainties of dynamic sensitivity and overshoot value. Conclusion: The measurement of explosion pressure in insensitive munitions tests is an important issue to the reporting test results and classifying reaction types. The more efforts to ensure the reliability of the insensitive munitions tests results are required.

An Experimental Study on the Energy Efficiency Ratio of Heat Pump for Air Source (공기열원 히트펌프의 에너지 효율 비율에 관한 실험적 연구)

  • SOON YOUNG JEONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.838-844
    • /
    • 2022
  • In this paper, an experimental study was conducted on the energy efficiency ratio of performance for air source heat pump. The energy efficiency ratio presents the operating efficiency of heat pump performance. In order to improve reliability in the energy efficiency ratio test of air source heat pump, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. The measurement uncertainty for the energy efficiency ratio test of air source heat pump was calculated and the measured results were presented.

A Suggestion of New Approach for Measurement of Remaining Prestress (잔존프리스트레스 측정을 위한 새로운 접근법 제안)

  • 이창수;김승익;김현겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.835-840
    • /
    • 2001
  • The new approach is a kind method of restoring temporary defect. Here, it is important for the defect not to occur problems of both local effect and global system. A basic concept is that it measures remaining prestress of PSC structures during the defect is restored. This study suggested new approach for measurement of remaining prestress. Two important results are obtained. First, safety problems, local stress concentration and global system, are very satisfied. Second, measurement value exists within error bound $\pm$ 1% in comparison with known value.

  • PDF

Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.95-98
    • /
    • 2023
  • Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.

Measurement Instruments for Superior Product Development: A Case Study of Deli Serdang Cassava in Indonesia

  • P, Remus Hasiholan;TARMIZI, Hasan Basri;RAHMANTA, Rahmanta;PURWOKO, Agus
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.1139-1145
    • /
    • 2021
  • This study is aimed at developing a measurement instrument for the superior product development program of Deli Serdang cassava, Indonesia. This research population is the target population of Deli Serdang Micro, Small and Medium-sized Enterprises (MSMEs) which produces cassava. The sample was randomly selected and consisted of 300 MSMEs. The study method is research and development with confirmatory factor analysis using Amos software. The data collection technique was a questionnaire. Study results used the maximum likelihood method which showed that the validity and reliability instruments met the ideal loading factor value > 0.5 and a significance value of p (0.000). The model built also meets the fit criteria based on the Goodness of Fit Model Standard. All instruments are presented to build and measure the superior cassava product development program by Deli Serdang MSMEs. This superior product development program comprises (1) economic contribution (with a loading factor value of 0.76) (2) social aspects (with a loading factor value of 0.76) (3) cultural aspects (with a loading factor value of 0.99) and (4) institutional (with a loading factor value of 0.87). This result means that all instruments have proven construct validity.

A Study of the Measurement of the Flow Coefficient Cv of a Ball Valve for Instrumentation (계장용 볼 밸브 유량계수 Cv 측정에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Jang, Se-Min;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.103-108
    • /
    • 2019
  • The results of the measurement of the flow-rate coefficient (Cv-value) and the analysis of a small ball valve are summarized follows. The Cv-values of 1/2-, 3/4- and 1-inch ball valves were measured using a flow-rate measurement test. The manufacturer obtained the Cv-value using a theoretical calculation method. The new experimental measurement and analysis method yielded more reliable results. In addition, the Cv value obtained through numerical analysis was almost identical the value provided by the manufacturer, which was based on experimental results. A Study on Flow Analysis results are all similar appearances as the reliability of the results.

Automated Print Quality Assessment Method for 3D Printing AI Data Construction

  • Yoo, Hyun-Ju;Moon, Nammee
    • Journal of Information Processing Systems
    • /
    • v.18 no.2
    • /
    • pp.223-234
    • /
    • 2022
  • The evaluation of the print quality of 3D printing has traditionally relied on manual work using dimensional measurements. However, the dimensional measurement method has an error value that depends on the person who measures it. Therefore, we propose the design of a new print quality measurement method that can be automatically measured using the field-of-view (FOV) model and the intersection over union (IoU) technique. First, the height information of the modeling is acquired from a camera; the output is measured by a sensor; and the images of the top and isometric views are acquired from the FOV model. The height information calculates the height ratio by calculating the percentage of modeling and output, and compares the 2D contour of the object on the image using the FOV model. The contour of the object is obtained from the image for 2D contour comparison and the IoU is calculated by comparing the areas of the contour regions. The accuracy of the automated measurement technique for determining, which derives the print quality value was calculated by averaging the IoU value corrected by the measurement error and the height ratio value.

FREQUENTLY CONVERGENT SOLUTIONS OF A DIFFERENCE EQUATION

  • Li, Hui;Bu, Fanqiang;Tao, Yuanhong
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.27 no.2
    • /
    • pp.173-181
    • /
    • 2014
  • In this paper, using the definition and properties of frequency measurement, we describe the properties of solutions of a difference equation as the initial value belongs to different intervals of the whole domain. We get the main result that if the initial value belongs to [-1, 1] which is different from $\frac{-1{\pm}\sqrt{5}}{2}$, then the solution defined by initial value have two frequent limits 0 and 1 of the same degree 0.5.

A Study on Grounding Resistance by Parallel Connection (병렬 접속에 의한 접지저항에 관한 연구)

  • 고희석;최종규;류희석;김주찬
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.307-312
    • /
    • 2002
  • For accuracy of an experiment, measure changing of grounding resistance by short period after construction and investigated the efficiency of grounding's different methode of parallel connection. We could confirm on measurement's accuracy, error through comparing the theoretical value and measured value. Therefore, reduction ratio can be expected from execution measurement to receive a target resistance value. By the result, we could evaluate the method of rod grounding electrode's proper execution

  • PDF

Value Orientation, Decision Making Style and family life Satisfaction -from the wives living in seoul- (가치상향 의사결정 樣式 및 가족생활 만족 -서울시 주부를 중심으로-)

  • 임정빈;문숙재
    • Journal of Families and Better Life
    • /
    • v.6 no.1
    • /
    • pp.149-166
    • /
    • 1988
  • The present study was initiated under the hypotheses that value orientation of wives is closely related to their decision making style in home management and that family life satisfaction of wives varies according to their decision making style. To test the hypotheses the following procedures were undertaken; (1) developing measurement instruments for value orientation, decision making style, and family life satisfaction; (2) finding value orientation of wives, their decision making style, and their family life satisfaction by applying the measurement instruments; (3) finding the variables highly affecting value orientation, decision making style and family life satisfaction ; and (4) finding the causal mechanism among value orientation, decision making style, and family life satisfaction. In conclusion , preferences of wives for humanism in value orientation were expected to lead decision making style to person -oriented rater than task-oriented style and , furthermore, to result in higher family life satisfaction.

  • PDF