• Title/Summary/Keyword: v-ray

Search Result 2,499, Processing Time 0.036 seconds

Image Quality Improvement through Energy Spectrum Change for X-ray (엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구)

  • Kim, Gu;Kim, Neung Gyun;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2021
  • When continuous X-ray are used when acquiring and X-ray image, even the same material may not be accurately represented in the image according to the thickness due to various X-ray energies. To solve this problem, the X-ray energy spectrum was changed to improve the image quality. Using SPEKTR v3.0, an X-ray energy spectrum with an additional filter added and a general X-ray energy spectrum using only a unique filter were obtained. Simulation was performed using the obtained X-ray energy spectrum as a radiation source for Geant4 Application for Tomographic Emission (GATE). Using GATE data, an X-ray image with an additional filter and an image reconstructed from and X-ray image without an additional filter were compared and analyzed through a mono energy image of 74 keV. In the case of using the X-ray energy spectrum without using an additional filter, the amount of X-rays transmitted according to the thickness of the same material is different from the amount that decreases according to the thickness of the material. Similar results were obtained as the amount decreased with the material thickness. In other words, a similar result was obtained when the reduced dose was used with a mono energy. When an X-ray image is obtained by changing an X-ray energy spectrum using an additional filter, a more accurate result of transmission of X-rays may be obtained. In radiological examination, it was confirmed that the appropriate use of the additional filter has a great effect on improving the image quality.

DESIGN OF A RISE TIME DISCRIMINATION CIRCUIT FOR X-RAY PROPORTIONAL COUNTER (X-선 비례계수관용 상승시간 선별회로 제작)

  • 남욱원;최철성
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.66-77
    • /
    • 1995
  • It is possible to distinguish X-ray events from non X-ray events in proportional conters using the method of rise time discrimination (RTD). In order to subtract non X-ray background, we have developed a simple RTD circuit which will be applied to the proportional counter planned for a sounding rocket experiment. The entire circuit consists of two parts ; the rise time measurement circuit and the time to amplitude conversion circuit which includes the self-calibration mode. From the test with X-ray detecting system, we obtained that the background can be rejected more than 80% in the energy band 2∼12 keV. However we confirmed that the RDT method is not proper to be used for the energy range above 12kV.

  • PDF

I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method (PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Sin, Jeong-Uk;Mun, Chi-Ung;Nam, Sang-Hee;Kim, Jin-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

A Comparative Study of Branching Ratio of 167Yb Radioactive Isotope from Gamma-ray Spectrum Produced by 169Tm(p,3n)167Yb Reaction with 100-MeV Proton Beam (100-MeV 양성자 빔을 이용하여 169Tm(p,3n)167Yb 반응에 의해 생성된 167Yb 방사성동위원소에서 방출되는 감마선 스펙트럼 비교 연구)

  • Sam-Yol, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.953-960
    • /
    • 2022
  • The measurement of branching ratio of 167Yb radioactive isotopes from gamma-ray spectrum of 169Tm(p,3n)167Yb reaction were performed by using a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). The 167Yb isotope has a half-life of 17.5 minutes and decays to 169Tm. The gamma rays generated from the 167Yb isotope were measured using an HPGe detector gamma ray spectroscopy system. The energy calibration of the detector and the efficiency measurement of the detector were determined using a standard source. The gamma rays of known main energy (62.9, 106.2, 113.3, 143.5 and 176.3 keV) were measured. On the other hand, information about the intensity of the generated gamma rays is very inaccurate. Therefore, in this study, the decay strength of the main gamma rays was accurately measured. Overall, it was different from the previously known results, and in particular, it was found that the intensity of the main decay gamma ray, such as the 113.3 and 106.2 keV gamma ray, was overestimated, and it was found that the gamma ray, such as 62.9, 116.7 and 143.5 keV was underestimated. The present results are considered to be important information in the fields of nuclear fusion, astrophysics and nuclear physics in the future.

Measurements of X-Ray Production Cross-Sections for 0.5¡­1.2-MeV Proton Beam (0.5~l.2-MeV 양성자빔에 대한 X-선 발생단면적의 측정)

  • Hae-ill BAK;Jun-Gyo BAK
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.108-115
    • /
    • 1990
  • The measurements of X-ray production cross-sections for 0.5~1.2-MeV proton beam are carried out on Cu and Au. For this experiment, the proton tram generated from the SNU 1.5-MV Tandem Van do Graaff accelerator is Incident on the target. The X-rays and the backscattered protons from the irradiated target are detected simultaneously by the Si(Li) X-ray detector and the SSB (Silicone Surface Barrier) charged particle detector The measured values of X-ray production cross-sections are compared with other experimental values and theoretical values such as the PWBA (Plane Wave Born Approximation) and the ECPSSR(Perturbed Stationary State corrected Energy loss, Coulomb deflection, Relativistic effects) values. For measured cross-sections near 1.0- MeV proton energy, the ECPSSR (D.D. Cohenet al., 1985) shows better agreement than the PWBA. Particularly, that of Au for 1.2 MeV proton beam is 9.69$\pm$ 0.39 barns which deviates from the ECPSSR by less than 5%. and the experimental data for 0.5~1.2- MeV proton agree with most of other experimental values within 30%.

  • PDF

Mössbauer Study of Crystallographic and Magnetic Properties in Vanadium Ferrite(VxFe3-xO4) Thin Films (바나듐 페라이트 박막의 결정구조 및 자기적 성질에 관한 뫼스바우어 분광학적 연구)

  • Park, Jae-Yun;Kim, Kwang-Joo
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.1
    • /
    • pp.19-23
    • /
    • 2008
  • The mixed ferrite $V_xFe_{3-x}O_4$(x=0.0, 0.15, 0.5, 1.0) thin films were prepared by sol-gel method. Their crystallographic and magnetic hyperfine properties have been studied using X-ray diffraction(XRD), X-ray photoelectron spectroscopy(XPS) and conversion electron $M\"{o}ssbauer$ spectroscopy(CEMS). The crystal structure is found to be cubic spinel throughout the series($x{\leq}1.0$), and the lattice parameter $a_0$ increases linearly with increasing V content. XRD, XSP and CEMS indicate that $V^{3+}$ substitution for $Fe^{3+}$ in B-site is superior to $V^{2+}$ substitution for $Fe^{2+}$ in B-site. It is noticeable that both quadrupole shift and hyperfine field decreases with increasing V composition, suggesting the change of local symmetry and accompanying line-broadening. The line-broadening on CEMS spectra can be explained by the distribution of magnetic hyperfine fields.

Revisiting the Correlations of Peak Luminosity with Spectral Lag and Peak Energy of the Observed Gamma-ray Bursts

  • Jo, Yun-A;Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.247-256
    • /
    • 2016
  • An analysis of light curves and spectra of observed gamma-ray bursts in gamma-ray ranges is frequently demanded because the prompt emission contains immediate details regarding the central engine of gamma-ray bursts (GRBs). We have revisited the relationship between the collimation-corrected peak luminosity and the spectral lag, investigating the lag-luminosity relationships in great detail by focusing on spectral lags resulting from all possible combinations of channels. Firstly, we compiled the opening angle data and demonstrated that the distribution of opening angles of 205 long GRBs is represented by a double Gaussian function having maxima at ~ 0.1 and ~ 0.3 radians. We confirmed that the peak luminosity and the spectral lag are anti-correlated, both in the observer frame and in the source frame. We found that, in agreement with our previous conclusion, the correlation coefficient improves significantly in the source frame. It should be noted that spectral lags involving channel 2 (25-50 keV) yield high correlation coefficients, where Swift/Burst Alert Telescope (BAT) has four energy channels (channel 1: 15-25 keV, channel 2: 25-50 keV, channel 3: 50-100 keV, channel 4: 100-200 keV). We also found that peak luminosity is positively correlated with peak energy.

Design and Fabrication of Hard X-ray Zone Plate (경 엑스선 존 플레이트(Zone Plate) 설계 및 제작)

  • Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.27-31
    • /
    • 2010
  • Spatial resolution is determined by the performance of x-ray optics used in the x-ray imaging system. A zone plate was designed for obtaining a high spatial resolution image at x-ray energy of 8.5keV. A spatial resolution of 80 nm was estimated by the ray tracing when an x-ray tube of tungsten targe was used instead of synchrotron radiation. The designed zone plate of outermost zone width of 40nm was successfully fabricated by the electron-beam lithography.

A study on the characteristic of material using V(z) curve of acoustic microscope (음향현미경의 V(z)곡선을 이용한 재료의 특성에 관한 연구)

  • Moon, G.;Ko, D.S.;Jun, K.S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.65-73
    • /
    • 1988
  • In this paper, V(z) curve has been analyzed theoretically and compared with the experimental result, and the relation between the V(z) curve and the material characteristic has been studied. Angular spectrum and ray optics theory have been used for theoretical analysis and the acoustic microscope operating at a center frequency of 3 MHz has been used for experiment. In experiment, it has been shown that each material has a V(z) curve of a unique form and the interval of dips appearing in the V(z) curves have been used to determine the Rayleigh wave velocity.

  • PDF

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.