• Title/Summary/Keyword: user sensitivity

Search Result 213, Processing Time 0.023 seconds

Development of Design Software for MEMS integrating Commercial Codes: DS/MEMS (상용코드 통합을 통한 미소기전집적시스템의 설계 소프트웨어 개발:DS/MEMS)

  • 허재성;이상훈;곽병만
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.11
    • /
    • pp.180-187
    • /
    • 2003
  • A CAD-based seamless design system for MEMS named DS/MEMS was developed which performs coupled-field analysis, optimal and robust design. DS/MEMS has been developed by means of integrating commercial codes and inhouse code-SolidWorks, FEMAP, ANSYS and CA/MEMS. This strategy results in versatility that means to include various analysis model, corresponding analyses and approximated design sensitivity analysis and user friendliness that design variables are taken to be selectable directly from a CAD model, that the problem is formulated under a window environment and that the manual job during optimization process is almost eliminated. DS/MEMS works on a parametric CAD platform, integrating CAD modeling, analysis, and optimization. Nonlinear programming algorithms, the Taguchi method, and response surface method are made available for optimization. One application problem is taken to illustrate the proposed methodology and show the feasibility of DS/MEMS as a practical tool.

Low Cost and Portable Parahydrogen Generator for the PHIP

  • Kwon, Soonmo;Min, Sein;Chae, Heelim;Namgoong, Sung Keon;Jeong, Keunhong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.21 no.4
    • /
    • pp.126-130
    • /
    • 2017
  • In the developed NMR hyperpolarization techniques, Parahydrogen-Induced Polarization (PHIP) technique is widely utilized to overcome the low sensitivity of the NMR/MRI. Parahydrogen generator is essential to produce high spin order of parahydrogen molecule. Commercial parahydrogen generator is well developed with user-friendly systems. However, it has drawbacks of long preparation time (~ 2h including cooling down time of 1h) and high cost (~ 200 million won) for the commercial setup. We designed a simple and portable parahydrogen generating system with low cost (~ 2 million won), which produce polarization in less than 1 min. With the designed parahydrogen generator, we successfully performed the PHIP with Wilkinson's catalyst on styrene. This study will broaden the parahydrogen based polarization transfer study on many researchers by providing the simple portable and low cost parahydrogen generator.

Evaluation of Economy Feasibility for Bridge Superstructures Using LCC Optimal Design (LCC 최적설계를 황용한 교량 상부구조의 경제성 평가)

  • Ahn Ye-Jun;Lee Kwang-Kyun;Park Jang-Ho;Shin Young-Seok
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.549-556
    • /
    • 2006
  • Life cycle cost is one of important factors in the evaluation of economy feasibility. Load carrying capacity curves for girders and decks are derived on the basis of bridge diagnostic results and condition grade curves to determine the service life and life cycle profile. The total life cycle costs including initial cost, damage cost, maintenance cost, user cost, and etc for the service life are calculated for steel box girder, PSC-I girder and rationalized plate girder. The optimal designs are performed for various service lifes and different superstructure types. The effects of parameters on the life cycle cost are investigated and the economy feasibility is evaluated through the sensitivity analysis.

  • PDF

Window-Based Computer Code Package CONPAS for an Integrated Level 2 PSA

  • Ahn, Kwang-Il;Kim, See-Darl;Song, Yong-Mann;Jin, Young-Ho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.493-498
    • /
    • 1996
  • A PC window-based computer code, CONPAS(CONtainment Performance Analysis System), has been developed to integrate the numerical, graphical and results-operation aspects of Level 2 probabilistic safety assessments (PSA) for nuclear power plants automatically. As a main logic for accident progression analysis, it employs a concept of the small containment phenomenological event tree(CPET) helpful to trace out visually individual accident progressions and of the large supporting event tree(LSET) for its detailed quantification. Compared with other existing computer codes for Level 2 PSA, the CONPAS code provides several advanced features: computational aspects including systematic uncertainty analysis, importance analysis, and sensitivity analysis, reporting aspects including tabling and graphic, and user-friend interface.

  • PDF

An Adaptive Image Quality Assessment Algorithm

  • Sankar, Ravi;Ivkovic, Goran
    • International journal of advanced smart convergence
    • /
    • v.1 no.1
    • /
    • pp.6-13
    • /
    • 2012
  • An improved algorithm for image quality assessment is presented. First a simple model of human visual system, consisting of a nonlinear function and a 2-D filter, processes the input images. This filter has one user-defined parameter, whose value depends on the reference image. This way the algorithm can adapt to different scenarios. In the next step the average value of locally computed correlation coefficients between the two processed images is found. This criterion is closely related to the way in which human observer assesses image quality. Finally, image quality measure is computed as the average value of locally computed correlation coefficients, adjusted by the average correlation coefficient between the reference and error images. By this approach the proposed measure differentiates between the random and signal dependant distortions, which have different effects on human observer. Performance of the proposed quality measure is illustrated by examples involving images with different types of degradation.

Robust Optimal Design of a Decoupled Vibratory Microgyroscope Considering Fabrication Influence (공정영향을 고려한 비연성 진동형 마이크로 자이로스코프의 강건 최적 설계)

  • Jeong Hee-Moon;Ha Sung Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1065-1074
    • /
    • 2004
  • A robust optimal design considering fabrication influence has been performed for the decoupled vibratory microgyroscope fabricated by the bulk micromachining. For the analysis of the gyroscope, a design tool has been developed, by which user can perform the system level design considering electric signal process and the fabrication influence as well as mechanical characteristics. An initial design of the gyroscope is performed satisfying the performances of scale factor (or sensitivity) and phase delay, which depend on the frequency difference between driving and sensing resonant frequencies. The objective functions are formulated in order to reduce the variances of the frequency difference and the frequency in itself by fabrication error. To certify the results, the standard deviations are calculated through the Monte Caries Simulation (MCS) and compared initial deviation that is measured fabricated gyroscope chip.

Dual-Chamber Technology: Safe and Convenient Drug Delivery for Lyophilized Biologics

  • Moore, John
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.1 no.1
    • /
    • pp.28-30
    • /
    • 2015
  • Biologics present a challenge to both the manufacturer and end user. They must usually be formulated as parenterals. However, they are often unstable in liquid form, due to their complex structure and composition. In that case, they must be manufactured using highly specialized processes, such as lyophilization (freeze-drying). Lyophilization nearly eliminates stability issues. Reducing a compound's sensitivity to temperature prolongs its shelf life. However, reconstitution can be cumbersome, involving multiple steps that increase the potential for error. Dual-chamber technology provides an effective alternative, combining a lyophilized drug and diluent in a closed system and enabling reconstitution in a few simple steps.

AUTOMATIC OBJECT SEGMENTATION USING MULTIPLE IMAGES OF DIFFERENT LUMINOUS INTENSITIES

  • Ahn, Jae-Kyun;Lee, Dae-Youn;Kim, Chang-Su
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.203-206
    • /
    • 2009
  • This paper represents an efficient algorithm to segment objects from the background using multiple images of distinct luminous intensities. The proposed algorithm obtains images with different luminous intensities using a camera flash. From the multiple intensities for a pixel, a saturated luminous intensity is estimated together with the slope of intensity rate. Then, we measure the sensitivities of pixels from their slopes. The sensitivities show different patterns according to the distances from the light source. Therefore, the proposed algorithm segments near objects using the sensitivity information by minimizing an energy function. Experimental results on various objects show that the proposed algorithm provides accurate results without any user interaction.

  • PDF

Characterization of three-dimensional ultrasonic anemometer using phase measurement (위상측정방식을 이용한 3차원 초음파 풍향풍속계의 특성분석)

  • Park, Do-Hyun;Yeh, Yun-Hae
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.442-448
    • /
    • 2006
  • Ultrasonic anemometers using pulse envelope detection-based method are standard instruments in most meteorological studies. In this paper, a new phase measurement method is tried to achieve the enhanced resolution without changing dimensions. The measurement sensitivity, dynamic range, and measurement speed of the new instrument are 0.2 mm/s, 13.3 m/s, and 13 measurements/sec, respectively. A graphic user interface is added to show the velocity and direction of the wind with the speed of sound and temperature of the wind in the 3 dimensional space. The new anemometer could be useful for the measurement of the air speed, the flow of fluids, and even air flow inside the downtown buildings.

Partially Coherent MC-CDMA Downlink Performance in Rayleigh Fading Channels

  • Kim, Nam-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.470-477
    • /
    • 2001
  • Multucarrier code-division multiple access(MC-CDMA) is one of the promising technique for high capacity wireless communication. Hower the carrier phase error and frequency offest cause the performance degradation of MC-CDMA due to the inter-carrier interference. In this work, downlink performance of the partially coherent MC-CDMA is analytically derived in Rayleigh fading channels. The bit error rate sensitivity by combining method, Maxiaml ratio combining (MRC)and Equal gain combining(EGC), is compared as functions of phase errors. multi-user interference, and received signal-to-noise ratio. The results show that the susceptibility for the performance degradation of EGc and MRC is negligible for loop SNR's of above 15 dB and above 10 dB, respectivtely.

  • PDF