• Title/Summary/Keyword: universal testing machine

Search Result 792, Processing Time 0.027 seconds

Reactive Compatibilization of Amorphous Poly-${\alpha}$-olefins/Amorphous Polyamide Blends (무정형 알파-올레핀 고분자/무정형 폴리아미드 블렌드의 반응 상용화)

  • Yun, Deok-Woo;Choi, Mi-Ju;Hwang, Kyu-Hee;Kim, Geon-Seok;Lee, Kwang-Hee
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.490-495
    • /
    • 2009
  • The reactive compatibilization of amorphous poly-${\alpha}$-olefins (APAO)/amorphous polyamide (aPA) blends was carried out using two kinds of reactive compatibilizers such as maleated polypropylene and ethylene-glycidyl methacrylate-methyl acrylate copolymer. The grafting reaction rates between aPA and the compatibilizers were examined using FT-IR, SEM and rheometer. The effect of the reactive compatibilization on the mechanical property of the blends was investigated with a universal testing machine. The adhesion strength of the blends including a hydrocarbon tackifier resin, C9 was also measured.

COMPARATIVE STUDIES ON THE RETENTIVE VALUES OF VARIOUS DENIAL CEMENTS USED TO RETAIN ORTHODONTIC BANDS (교정용 BANDS 접착에 사용되는 각종 치과용 시멘트의 유지력에 관한 비교 연구)

  • Kim, Joo Young;Ryu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.11 no.2
    • /
    • pp.151-160
    • /
    • 1981
  • The purpose of this study was to compare the retentive values of various dental cements used for cementing the orthodontic bands on the teeth. Sound freshly extracted human premolar teeth were selected for the study. Eleven commercial dental cements (Zinc phosphate, reinforced Zinc-oxide eugenol, Carboxylate and Glass ionomer cements) were handled under standardized conditions. All cemented speciments were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C$ and more than $95\%$ relative humidity and tested after 24 hours and 1 week each. The force required to remove the cemented orthodontic bands from the teeth was determined on an Instron Universal Testing Machine using a modified specimen holding device with a cross-head speed of 0.20mm/min. The results obtained were as follows: 1, The retentive values of the band cemented with zinc phosphate cements and carboxylate cements were considerably higher than those of the reinforced zinc oxide-eugenol and glass ionomer cements. 2. There was no significant difference between the retentive value of carboxylate cements as compared with zinc phosphate cements. 3. The retentive value of the reinforced zinc oxide eugenol cements was lowest all of the coements. The retentive values expressed for all cements up to at least one week were highly but no significant difference was found between the 24-hour and 7 day time intervals.

  • PDF

Experimental Evaluation of Mechanical Properties for the Carbon/Epoxy Composite Laminates at Low Temperature (탄소섬유/에폭시 복합적층판에 대한 저온에서의 기계적특성 실험평가)

  • Her, N.I.;Sa, J.W.;Cho, S.;Do, C.J.;Oh, Y.K.;Choi, C.H.;Kwon, M.;Lee, G.S.;Lee, S.Y.;Kim, J.H.
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.41-44
    • /
    • 2001
  • Mechanical test of the Carbon Fiber Reinforced Plastics (CFRP) composite specimen was performed based on the ASTM code at the ambient and low temperature. Tension, compression in-plane shear, and inter-laminar shear properties of the composite laminates were evaluated experimentally using the Universal Testing Machine(UTM) system at the temperature of $24^{\circ}C$,$-76^{\circ}C$ , and $-196^{\circ}C$. From the test results it was found that the CFRP chosen for the Korea Superconducting Tokamak Advanced Research(KSTAR) magnet supporting post had smaller tensile strength and larger compressive strength at the low temperature than those of the ambient temperature because of material ductility.

  • PDF

Temperature and pH-Responsive Release Behavior of PVA/PAAc/PNIPAAm/MWCNTs Nanocomposite Hydrogels

  • Jung, Gowun;Yun, Jumi;Kim, Hyung-Il
    • Carbon letters
    • /
    • v.13 no.3
    • /
    • pp.173-177
    • /
    • 2012
  • A drug delivery system (DDS) was prepared with a temperature and pH-responsive hydrogel. Poly(vinyl alcohol) (PVA)/poly(acrylic acid) (PAAc)/poly(N-isopropylacrylamide) (PNIPAAm)/multi-walled carbon nanotube (MWCNT) nanocomposites were prepared by radical polymerization for the temperature and pH-responsive hydrogels. MWCNTs were employed to improve both the thermal conductivity and mechanical properties of the PVA/PAAc/PNIPAAm/MWCNT nanocomposite hydrogels. Various amounts of MWCNTs (0, 0.5, 1 and 3 wt%) were added to the nanocomposite hydrogels. PVA/PAAc/PNIPAAm/MWCNT nanocomposite hydrogels were characterized with a scanning electron microscope. The mechanical properties were measured with a universal testing machine. Swelling and releasing properties of nanocomposite hydrogels were investigated at various temperatures and pHs. Temperature and pH-responsive release behavior was found to be dependent on the content of MWCNTs in nanocomposite hydrogels.

The Effect of Molecular Weight and the Linear Velocity of Drum Surface on the Properties of Electrospun Poly(ethylene terephthalate) Nonwovens

  • Kim, Kwan-Woo;Lee, Keun-Hyung;Khil, Myung-Seob;Ho, Yo-Seung;Kim, Hak-Yong
    • Fibers and Polymers
    • /
    • v.5 no.2
    • /
    • pp.122-127
    • /
    • 2004
  • In this study, we evaluated the effect of the molecular weight of the polymer on electrospun poly(ethylene terephthalate) (PET) nonwovens, and their mechanical properties as a function of the linear velocity of drum surface. Polymer solutions and electrospun PET nonwovens were characterized by means of viscometer, tensiometer, scanning electron microscope(SEM), wide angle X-ray diffraction measurement (WAXD) and universal testing machine (UTM). By keeping the uniform solution viscosity, regardless of molecular weight differences, electrospun PET nonwovens with similar average diameter could be obtained. In addition, the mechanical properties of the electrospun PET nonwovens were strongly dependent on the linear velocity of drum surface. From the results of the WAXD scan, it was found that the polymer took on a particular molecular orientation when the linear velocity of drum surface was increased. The peaks became more definite and apparent, evolving from an amorphous pattern at 0 m/min to peaks and signifying the presence of crystallinity at 45 m/min.

The Effect of MnO2 Content on the Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.4
    • /
    • pp.331-339
    • /
    • 2017
  • Porous alumina-based ceramics are of special interest due to their outstanding mechanical properties and their thermal and chemical stability. Nevertheless, the high electrical resistance of alumina-based ceramics, due to the generation of static electricity, leads to difficulty in applying a vacuum chuck in the semi-conductor process. Therefore, development of alumina-based ceramics for applications with vacuum chucks aims to have primary properties of low electrical resistance and high air permeability. In this study, we tailored the electrical resistance of porous alumina-based ceramics by adjusting the amount of $MnO_2$ (with $TiO_2$ fixed at an amount of 2 wt%) and by using coarse alumina powder for high air permeability. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimeter, capillary flow porosimetry, universal testing machine, X-ray diffraction and high-resistance meter.

EFFECTS OF OVERDENTURE RETENTION ON THE AXIAL LOAD OF IMPLANT IN THE MANDIBULAR IMPLANT-SUPPORTED OVERDENTURE (하악 임플란트지지 오버덴춰에서 바 어태치먼트의 유지력이 임플란트의 축력에 미치는 영향)

  • Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.1
    • /
    • pp.98-107
    • /
    • 2000
  • Three linear strain gauges (KFR-02N-120-C1-23, Kyowa, Japan) were placed around the abutment of implant future and the maximum axial loads on the mandibular implants supporting over dentures were registered in experimental model when the overdenture was removed. The overdenture attachments used in this study were Round bar Hader bar, Dolder bar with and with out spacer. The retention of bar attachment was measured using universal testing machine while being con-trolled by Activating set and Deactivator except in case of the Hader bar. Simultaneously strains were recorded with the strain smart program in strain P-6000 series (Measurement group, Raleigh, USA). The maximum axial load was calculated and compared with each other. The results were as follows: 1. The amount and the timing of the maximum axial loads were different between the right and left implant in all attachment systems. 2. The retention of bar attachment except Hader bar could be adjusted but the controllability was different among the attachment systems. 3. The more the axial load, the higher the retention with Hader bar and Dolder bar without spacer. but the tendency of increase was not shown with round bar and Dolder bar with spacer.

  • PDF

THE COMPARISON OF INITIAL RETENTIVE FORCE IN DIFFERENT DOUBLE CROWN SYSTEMS

  • Kwon, Ho-Beom;Roh, Yoon-Ho;Lee, Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.6
    • /
    • pp.677-682
    • /
    • 2006
  • Statement of problem. Various double crown systems have been used with removable partial dentures in the clinical field. Although retentive force between inner and outer crown are affected by several factors, differences between the retentive forces of different double crown system types are expected. Purpose. The purpose of this study was to evaluate the initial retentive force of outer crowns fabricated by the conventional casting technique in conus and hybrid double crowns. Material and methods. Ten double crowns were fabricated. The groups were as follows. Group 1, double crowns of hybrid inner and outer crowns using the conventional casting method; Group 2, double crowns of conus inner and outer crowns using the conventional casting method. Tensile strengths of double crowns when the inner and outer crowns were separated on a universal testing machine were measured. These values of retentive force were then statistically analyzed using the Kruskal-Wallis test. Results. Retentive force in group 2 was significantly higher than that in group 1(p<.05). Conclusion. The initial retentive forces of double crowns were affected by the types of the double crown system.

Effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength and bond failure mode of metallic orthodontic brackets

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ippolito, Daniela Rita;Gatto, Maria Rosaria;Checchi, Luigi
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.44-49
    • /
    • 2014
  • Objective: To evaluate the effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength (SBS) and bond failure mode of metallic orthodontic brackets. Methods: Adhesive pre-coated metallic brackets were bonded to 72 extracted human premolars embedded in autopolymerizing acrylic resin. The teeth were randomly divided into 3 groups (n = 24 each) to undergo no treatment (control group) or ultrasonic instrumentation with a scaler-tip angulation of $45^{\circ}$ ($45^{\circ}$-angulation group) or $0^{\circ}$ ($0^{\circ}$-angulation group). SBS was tested in a universal testing machine, and adhesive remnant index (ARI) scores were recorded. The Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis. Results: The control group had a significantly higher mean SBS value than the treated groups, which showed no significant differences in their mean SBS values. The ARI scores were not significantly different among the groups. Conclusions: Ultrasonic instrumentation around the bracket base reduces the SBS of metallic orthodontic brackets, emphasizing the need for caution during professional oral hygiene procedures in orthodontic patients. The scaler-tip angulation does not influence the SBS reduction and bond failure mode of such brackets.

Debonding forces of three different customized bases of a lingual bracket system

  • Sung, Jang-Won;Kwon, Tae-Yub;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.43 no.5
    • /
    • pp.235-241
    • /
    • 2013
  • Objective: The purpose of this study was to investigate whether extension of the custom base is necessary for enhancement of bond strength, by comparing the debonding forces and residual adhesives of 3 different lingual bracket systems. Methods: A total of 42 extracted upper premolars were randomly divided into 3 groups of 14 each for bonding with brackets having (1) a conventional limited resin custom base; (2) an extended gold alloy custom base: Incognito${TM}$; and (3) an extended resin custom base: KommonBase${TM}$. The bonding area was measured by scanning the bracket bases with a 3-dimensional digital scanner. The debonding force was measured with an Instron universal testing machine, which applied an occlusogingival shear force. Results: The mean debonding forces were 60.83 N (standard deviation [SD] 10.12), 69.29 N (SD 9.59), and 104.35 N (SD17.84) for the limited resin custom base, extended gold alloy custom base, and extended resin custom base, respectively. The debonding force observed with the extended resin custom base was significantly different from that observed with the other bases. In addition, the adhesive remnant index was significantly higher with the extended gold alloy custom base. Conclusions: All 3 custom-base lingual brackets can withstand occlusal and orthodontic forces. We conclude that effective bonding of lingual brackets can be obtained without extension of the custom base.