• Title/Summary/Keyword: unit generation rate

Search Result 117, Processing Time 0.026 seconds

Process Analysis and Simulation for System of Air Liquefaction Separation Using LNG Cold Energy (LNG 냉열을 이용한 공기액화분리시스템의 시뮬레이션 및 공정 해석)

  • HAN, DANBEE;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.276-281
    • /
    • 2019
  • The process of separating oxygen and nitrogen from the air is mainly performed by electric liquefaction, which consumes a lot of electricity, resulting in higher operating costs. On the other hand, when used for cold energy of LNG, electric power can be reduced compared to the electric Linde cycle. Currently, LNG cold energy is used in the cold refrigeration warehouse, separation of air-liquefaction, and LNG cold energy generation in Japan. In this study, the system using LNG cold energy and the Linde cycle process system were simulated by PRO/II simulators, respectively, to cool the elevated air temperature from the compressor to about $-183^{\circ}C$ in the air liquefaction separation process. The required amount of electricity was compared with the latent heat utilization fraction of LNG, the LNG supply pressure, and the LNG cold energy usage. At the air flow rate of $17,600m^3/h$, the power source unit of the Linde cycle system was $0.77kWh/m^3$, compared with $0.3kWh/m^3$.

A Study on Malicious Code Detection Using Blockchain and Deep Learning (블록체인과 딥러닝을 이용한 악성코드 탐지에 관한 연구)

  • Lee, Deok Gyu
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.2
    • /
    • pp.39-46
    • /
    • 2021
  • Damages by malware have recently been increasing. Conventional signature-based antivirus solutions are helplessly vulnerable to unprecedented new threats such as Zero-day attack and ransomware. Despite that, many enterprises have retained signature-based antivirus solutions as part of the multiple endpoints security strategy. They do recognize the problem. This paper proposes a solution using the blockchain and deep learning technologies as the next-generation antivirus solution. It uses the antivirus software that updates through an existing DB server to supplement the detection unit and organizes the blockchain instead of the DB for deep learning using various samples and forms to increase the detection rate of new malware and falsified malware.

A Study on the Spatial Units Adequacy for the Regional Pricing of Electricity: Based on Electricity Self-sufficiency Rates by Si·Gun·Gu (지역별 차등 전기요금제 적용을 위한 공간 단위 검토: 시·군·구별 전력 자급률을 기준으로)

  • Chung Sup Lee;Kang-Won Lee
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.96-109
    • /
    • 2023
  • Recently, there has been a lot of discussion about the regional pricing of electricity and electricity self-sufficiency. In Korea, power generation facilities are highly ubiquitous and there is an imbalance between electricity production and consumption regions. So it is proposed to charge different price by region, instead of the current nationwide uniform price, and the regional electricity self-sufficiency rate is proposed as a criterion for identifying electricity production and consumption regions. However, many discussions set the spatial unit for measuring electricity self-sufficiency by 17 Si·Do, which needs to be analyzed for its appropriateness. In this study, we analyzed the electricity self-sufficiency rate using 17 provinces and 229 Si·Gun·Gu as the spatial unit. As a result of the analysis, there are 7 and 10 electricity producing and consuming regions at Si·Do level, but 38 and 191 at Si·Gun·Gu level. In addition, although the electricity self-sufficiency rate measurement has the advantage of identifying electricity production and consumption areas in a simple and intuitive way, we points out that it has some problems with the criteria for regional pricing of electricity.

Assessment of GHG Emission Reduction Potential in Extension of Nuclear and Renewable Energy Electricity Generation (원자력과 신재생에너지 발전설비 확대에 따른 온실가스 저감 잠재량에 관한 연구)

  • Jun, Soo-Young;Park, Sang-Won;Song, Ho-Jun;Park, Jin-Won
    • Journal of Energy Engineering
    • /
    • v.18 no.3
    • /
    • pp.191-202
    • /
    • 2009
  • South Korea, ranks 10th largest emitter of carbon dioxide in the world, will probably be under the obligation to reduce GHG emission from 2013. It is very important to reduce the electrical energy consumption since 30% of GHG emission in South Korea is made during electricity generation. In this study, based on "the 1st national energy master plan", the GHG emission reduction potential and the feasibility of the scenario in the electricity generation have been analyzed using LEAP(Long-range Energy Alternative Planning system). The scenario of the mater plan contains the 41% expansion of nuclear power plant facilities and the 11% diffusion of renewable energy until 2030. In result, total $CO_2$ emission reduction rate is 28.8% in 2030. Also $CO_2$ emission of unit electricity generation of bituminous coal power plant is $0.85kgCO_2/kWh$ and its LNG power plant is $0.51kgCO_2/kWh$ in BAU scenario. Therefore when existing facilities is exchanged for nuclear or renewable energy power plant, substitute of bituminous power plant is more effective than LNG power.

Annual Energy Performance Evaluation of Zero Energy House Using Metering Data (실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가)

  • Lim, Hee-Won;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

A Study on Hydrogen Impurity Effect in Anode of Proton Exchange Membrane Fuel Cell on Various Concentration of CO and H2S (고분자전해질 연료전지 연료극의 일산화탄소 및 황화수소 농도에 따른 불순물영향에 관한 연구)

  • LEE, EUN-KYUNG;BAEK, JAE-HOON;LEE, JUNG-WOON;LEE, SEUNG-KUK;LEE, YEON-JAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.670-676
    • /
    • 2016
  • Hydrogen town in Republic of Korea was established in 2013. Hydrogen as a byproduct produced by various processes of factories is used in hydrogen town facilities. As cell performance is affected by contaminations in fuel gas, various standards about impurities of fuel have been determined by many countries. This study shows performance degradation of single cell with impurities concentrations. Traces of carbon monoxide (CO) and hydrogen sulfide ($H_2S$)can cause considerable cell performance losses. For comparing the performances by poisoning of CO, acceleration test, I-V curve, constant current are performed. Both the CO and $H_2S$ poisoning rate are a function of their concentration. With the higher concentrations the higher poisoning rates are observed. And, it was confirmed that, oxidation behavior and side reaction generation are not affected. Under the lower $H_2S$ concentration condition, the poisoning rate is much higher than that of CO because of its different adsorption intensity. It can be possible that the result of this study can be used for enacting regulation as a baseline data.

Cardiovascular Neurons Mediating Somatosympathetic Reflex in Rostral Ventrolateral Medulla

  • Goo, Yong-Sook;Kim, Sang-Jeong;Kim, Jun;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.185-197
    • /
    • 1993
  • The rostral ventrolateral medulla (RVLM) includes vasopressor neurons, which transmit activation signals to the intermediolateral nucleus (IML) of the spinal cord, where the preganglionic sympathetic nucleus is located, to raise arterial blood pressure (BP). However, controversy exists as to the possible depressor area in the RVLM and the pathway involved. The present study persued evidence far the location of depressor neurons and the pathway by simultaneously observing changes in BP and the firing rate (FR) of cardiovascular neurons (CVNs) in the RVLM during the somatosympathetic reflex (SSR) elicited by peripheral nerve stimulation, since CVNs are known to contribute to the generation of the sympathetic nerve discharge. In 42 cats, anaesthetized with $\alpha-chloralose$, single unit recording was performed, using carbon filament electrodes inserted into the RVLM, enabling estimation of the post R wave unit histogram (PR-UNlT) and the spike triggered average of sympathetic nerve discharge (STA-SND), allowing identification of CVNs. Antidromic stimulation of spinal $T_2$ segment was followed to determine whether the identified CVN projects axonal endings to the spinal cord (reticulospinal neuron). The sciatic nerve was electrically stimulated at $A\delta-intensity$ (1 mA, 0.1 ms), 1 Hz and C-intensity (10 mA, 0.5 ms), 20 Hz to elicit the depressor, and pressor responses of the SSR, respectively. Simultaneous measurement of CVN firing rate was made. Experimental results are summarized as follows. 1) 20 out of 98 CVNs had axonal projections to the spinal cord and 17 out of 98 CVNs showed FR changes during SSR. 2) Response patterns of FR and BP during SSR were classified into 8 types. 3) These 8 different response patterns could be further classified into those from pressor and depressor neurons. These results demonstrate that some CVNs were identifiable as reticulospinal neurons responding to anti-dromic stimulation and that CVNs operating as depressor neurons as well as pressor neurons exist in the RVLM, both of which are involved with SSR mediation. Therefore, evidence was found that an independent depressor pathway might be involved in the mediation of SSR.

  • PDF

Evaluation of Optimal Time Between Overhaul Period of the First Driving Devices for High-Speed Railway Vehicle (고속철도차량 1차 구동장치에 대한 완전분해정비의 최적 주기 평가)

  • Jung, Jin-Tae;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8700-8706
    • /
    • 2015
  • The first driving device of the power bogies for the Korean high-speed railway vehicle consists of the traction motor (TM) and the motor reduction gears unit (MRU). Although TM and MRU are the mechanically integrated structures, their time between overhauls (TBO) have two separate intervals due to different technical requirements(i.e. TBO of MRU: $1.8{\times}10^6km$, TBO of TM: $2.5{\times}10^6km$). Therefore, to reduce the unnecessary number of preventive maintenances, it is important to evaluate the optimal TBO with a viewpoint of reliability-center maintenance towards cost-effective solution. In this study, derived from the field data in maintenance, fault tree analysis and failure rate of the subsystem considering criticality of the components are evaluated respectively. To minimize the conventional total maintenance cost, the same optimal TBO of the components is derived from genetic algorithm considering target reliability and improvement factor. In this algorithm, a chromosome which comprised of each individual is the minimum preventive maintenance interval. The fitness function of the individual in generation is acquired through the formulation using an inverse number of the total maintenance cost. Whereas the lowest common multiple method produces only a four percent reduction compared to what the existing method did, the optimal TBO of them using genetic algorithm is $2.25{\times}10^6$km, which is reduced to about 14% comparing the conventional method.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Development of Predictive Growth Model of Vibrio parahaemolyticus Using Mathematical Quantitative Model (수학적 정량평가모델을 이용한 Vibrio parahaemolyticus의 성장 예측모델의 개발)

  • Moon, Sung-Yang;Chang, Tae-Eun;Woo, Gun-Jo;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.349-354
    • /
    • 2004
  • Predictive growth model of Vibrio parahaemolyticus in modified surimi-based imitation crab broth was investigated. Growth curves of V. parahaemolyticus were obtained by measuring cell concentration in culture broth under different conditions ($Initial\;cell\;level,\;1{\times}10^{2},\;1{\times}10^{3},\;and\;1{\times}10^{4}\;colony\;forming\;unit\;(CFU)/mL$; temperature, 15, 25 37, and $40^{\circ}C$; pH 6, 7, and 8) and applying them to Gompertz model. Microbial growth indicators, maximum specific growth rate (k), lag time (LT), and generation time (GT), were calculated from Gompertz model. Maximum specific growth rate (k) of V. parahaemolyticus increased with increasing temperature, reaching maximum rate at $37^{\circ}C$. LT and GT were also the shortest at $37^{\circ}C$. pH and initial cell number did not influence k, LT, and GT values significantly (p>0.05). Polynomial model, $k=a{\cdot}\exp(-0.5{\cdot}((T-T_{max}/b)^{2}+((pH-pH_{max)/c^{2}))$, and square root model, ${\sqrt{k}\;0.06(T-9.55)[1-\exp(0.07(T-49.98))]$, were developed to express combination effects of temperature and pH under each initial cell number using Gauss-Newton Algorism of Sigma plot 7.0 (SPSS Inc.). Relative coefficients between experimental k and k Predicted by polynomial model were 0.966, 0.979, and 0.965, respectively, at initial cell numbers of $1{\times}10^{2},\;1{\times}10^{3},\;and\;1{\times}10^{4}CFU/mL$, while that between experimental k and k Predicted by square root model was 0.977. Results revealed growth of V. parahaemolyticus was mainly affected by temperature, and square root model showing effect of temperature was more credible than polynomial model for prediction of V. parahaemolyticus growth.