Abstract
Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.
Keywords
Energy Independence Rate; Energy Zero House; Energy Consumption Unit;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Y. Kwan, L. Guan, "Design a Zero Energy House in Brisbane", Australia, Procedia Engineering 121, 2015, 604-611   DOI
2 Liping Wang, Julie Gwilliam, Phil Jones, "Case study of zero energy house design in UK", Energy and Buildings, Vol. 41, 2009.
3 정선영, 백남춘, 윤종호, 신우철, 김용경, 강승훈, 제로에너지 솔라하우스(KIER ZeSH-II)의 에너지성능 측정 및 에너지자립도 분석, 대한건축학회, 대한건축학회 논문집, Vol. 27, No. 12, 307-314, 2011 // (Jeong, Seon-Yeong, Baek, Nam-Choon, Yoon, Jong-Ho, Shin, U-Cheul, Kim, Yong-Kyoung, Kang, Seung-Hoon, "The Study on Energy Performance Measurement and Energy Self-sufficiency Analysis of KIER Zero Energy Solar House II", Journal of the Architectural Institute of Korea Planning & Design, Vol 27, No 12, 2011)
4 백남춘, 김성범, 오병칠, 윤종호, 신우철, "실측데이터를 이용한 저에너지주택의 에너지성능평가", 대한설비공학회, 설비공학논문집 제27권 제7호, 2015 // (Namchoon Baek, Sungbum Kim, Byungchil Oh, Jongho Yoon, Ucheul Shin, "Energy Performance Evaluation of Low Energy Houses using Metering Data", Korean Journal of Air-Conditioning and Refrigeration Engineering Vol. 27, No. 7, 2015)
5 Autodesk, Ecotect Analysis 2011
6 bre, Passivhaus primer: Designer's guide: A guide for the design teamand local authorities.
7 신우철, 이왕제, 윤종호, 백남춘, "주거용 건물의 개별 환기시스템 필요성에 관한 연구", 한국생태환경건축학회 논문집 제14권 제6호, 2014. // (Shin, U-Cheul, Lee, Wang-Je, Yoon, Jong-Ho, Baek, Nam-Choon, "The Individual Heat-recovery ventilation system of Residential Buildings", Korea Institute of Ecological Architecture and Environment Vol. 14, No. 6, 2014)
8 Lee, Hyun-Seung, Kim Sung-Bum, Shin U-Cheul, "The Economics Evaluation of Grid-connected Photovoltaic Systems in Residential Houses", Korea Institute of Ecological Architecture and Environment Vol. 15, No. 6, 2015