• Title/Summary/Keyword: tube plate

Search Result 498, Processing Time 0.027 seconds

Experimental and numerical investigation on exposed RCFST column-base Joint

  • Ben, Mou;Xingchen, Yan;Qiyun, Qiao;Wanqiu, Zhou
    • Steel and Composite Structures
    • /
    • v.45 no.5
    • /
    • pp.749-766
    • /
    • 2022
  • This paper investigates the seismic performance of exposed RCFST column-base joints, in which the high-strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens with different axial force ratios (n = 0, 0.25, and 0.5) were tested under cyclic loadings. Finite element analysis (FEA) models were validated in the basic indexes and failure mode. The hysteresis behavior of the exposed RCFST column-base joints was studied by the parametrical analysis including six parameters: width of column (D), width-thickness ratio (D/t), axial force ratio (n), shear-span ratio (L/D), steel tube strength (fy) and concrete strength (fc). The bending moment of the exposed RCFST column-base joint increased with D, fy and fc. But the D/t and L/D play a little effect on the bending capacity of the new column-base joint. Finally, the calculation formula is proposed to assess the bending moment capacities, and the accuracy and stability of the formula are verified.

Sound Absorption of Natural Fiber Composite from Sugarcane Bagasse and Coffee Silver Skin

  • Wachara KALASEE;Putipong LAKACHAIWORAKUN;Visit EAKVANICH;Panya DANGWILAILUX
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.470-480
    • /
    • 2023
  • This study aimed to develop a sound-absorbing composite using sugarcane bagasse (SB) and coffee silver skin (CS) as raw materials. The composite boards were manufactured by bonding the fibers with Melamine Urea-Formaldehyde adhesive, ensuring a consistent thickness of 30 mm. Various densities were employed, namely 380, 450, and 520 kg/m3. The samples were fabricated with different fiber ratios, including SB100%, SB75% with CS25%, and SB50% with CS50%. The sound absorption coefficient (SAC) and noise reduction coefficient (NRC) were measured using the impedance tube method within a frequency range of 63-6,300 Hz. The experimental results revealed that the mixing ratio of CS exerted a notable influence on enhancing the SAC, while the density of the composite board exhibited a significant impact on increasing both the SAC and NRC. Among the densities tested, the optimal value was observed at 520 kg/m3, yielding a SAC value of 0.65 at a frequency of 1,000 Hz and an NRC value of 0.55 for the SB50-CS50 composite plate. These findings underscore the importance of considering the CS mixing ratio and composite board density when aiming to optimize sound absorption properties.

Isolation and characterization of a lytic Salmonella Typhimurium-specific phage as a potential biofilm control agent

  • Su-Hyeon Kim;Mi-Kyung Park
    • Food Science and Preservation
    • /
    • v.30 no.1
    • /
    • pp.42-51
    • /
    • 2023
  • This study aimed to characterize a lytic Salmonella Typhimurium-specific (ST) phage and its biofilm control capability against S. Typhimurium biofilm on polypropylene surface. ST phage was isolated, propagated, and purified from water used in a slaughterhouse. The morphology of ST phage was observed via transmission electron microscopy. Its bactericidal effect was evaluated by determining bacterial concentrations after the phage treatment at various multiplicities of infection (MOIs) of 0.01, 1.0, and 100. Once the biofilm was formed on the polypropylene tube after incubation at 37℃ for 48 h, the phage was treated and its antibiofilm capability was determined using crystal violet staining and plate count method. The phage was isolated and purified at a final concentration of ~11 log PFU/mL. It was identified as a myophage with an icosahedral head (~104 nm) and contractile tail (~90-115 nm). ST phage could significantly decrease S. Typhimurium population by ~2.8 log CFU/mL at an MOI of 100. After incubation for 48 h, biofilm formation on polypropylene surface was confirmed with a bacterial population of ~6.9 log CFU/cm2. After 1 h treatment with ST phage, the bacterial population in the biofilm was reduced by 2.8 log CFU/cm2. Therefore, these results suggest that lytic ST phage as a promising biofilm control agent for eradicating S. Typhimurium biofilm formed on food contact surfaces.

Comparison of Dose and Quality of Copper and Nickel Additional Filter Plate in Diagnostic X-ray Generator (진단용 엑스선 발생장치에서 부가 여과판에 따른 선량과 화질 비교)

  • Lee, Hyun-Kyung;Go, Yu-Rim;Park, Young-Kyeong;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.459-466
    • /
    • 2017
  • The purpose of this study was to evaluate the difference of dose and image quality according to the material of the additional filter plate by selecting copper and nickel. First, the absorbed dose was measured using a Rando phantom setting the additional filter plates of copper and nickel None, 0.1 mm, 0.2 mm, and 0.3 mm under 120 kVp, and 6.3 mAs. Second, We acquired image according to filter thickness of copper and nickel. by changing the tube voltage of 90 kVp, 100 kVp, 110 kVp, 120 kVp and exposure indexes of 400, 800 and 1600. Third, we obtained the SNR and CNR values using the Image J program and evaluated quantitatively and then evaluated image quality. As a result, Absorbed dose measurements showed that nickel was higher than copper, and the absorbed dose decreased as the thickness increased(p<0.05). Furthermore, Quantitative analysis of images showed no significant difference between the two images according to change the voltage and the exposure index(p>0.05). In conclusion, this study confirms that the nickel addition plate can maintain the current image quality while reducing the exposure dose compared to copper.

Mass Screening of Lovastatin High-yielding Mutants through Statistical Optimization of Sporulation Medium and Application of Miniaturized Fungal Cell Cultures (Lovastatin 고생산성 변이주의 신속 선별을 위해 통계적 방법을 적용한 Sporulation 배지 개발 및 Miniature 배양 방법 개발)

  • Ahn, Hyun-Jung;Jeong, Yong-Seob;Kim, Pyeung-Hyeun;Chun, Gie-Taek
    • KSBB Journal
    • /
    • v.22 no.5
    • /
    • pp.297-304
    • /
    • 2007
  • For large and rapid screening of high-yielding mutants of lovastatin produced by filamentous fungal cells of Aspergillus terreus, one of the most important stage is to test as large amounts of mutated strains as possible. For this purpose, we intended to develop a miniaturized cultivation method using $7m{\ell}$ culture tube instead of traditional $250m{\ell}$ flask (working volume $50m{\ell}$). For obtaining large amounts of conidiospores to be used as inoculums for miniaturized cultures, 4 components i.e., glucose, sucrose, yeast extract and $KH_2PO_4$ were intensively investigated, which had been observed to show positive effect on enhancement of spore production through Plackett-Burman design experimet. When optimum concentrations of these components that were determined through application of response surface method (RSM) based on central composite design (CCD) were used, maximum spore numbers amounting to $1.9\times10^{10}$ spores/plate were obtained, resulting in approximately 190 fold increase as compared to the commonly used PDA sporulation medium. Using the miniaturized cultures, intensive strain development programs were carried out for screening of lovastatin high-yielding as well as highly reproducible mutants. It was observed that, for maximum production of lovastatin, the producers should be activated through 'PaB' adaptation process during the early solid culture stage. In addition, they should be proliferated in condensed filamentous forms in miniaturized growth cultures, so that optimum amounts of highly active cells could be transferred to the production culture-tube as reproducible inoculums. Under these highly controlled fermentation conditions, compact-pelleted morphology of optimum size (less than 1 mm in diameter) was successfully induced in the miniaturized production cultures, which proved essential for maximal utilization of the producers' physiology leading to significantly enhanced production of lovastatin. As a result of continuous screening in the miniaturized cultures, lovastatin production levels of the 81% of the daughter cells derived from the high-yielding producers turned out to be in the range of 80%$\sim$120% of the lovastatin production level of the parallel flask cultures. These results demonstrate that the miniaturized cultivation method developed in this study is efficient high throughput system for large and rapid screening of highly stable and productive strains.

Preliminary Study for Development of Low Dose Radiation Shielding Material Using Liquid Silicon and Metalic Compound (액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구)

  • Jang, Seo Goo;Han, Su Chul;Kang, Sung Jin;Lim, sung wook;Lee, Sung Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.461-468
    • /
    • 2017
  • This study measured and compared the protective clothing using Pb used for shielding in a diagnostic X-ray energy range, and the shielding rates of X-ray fusion shielding materials using Si and $TiO_2$. For the experiment, a pad type shielding with a thickness of 1 mm was prepared by mixing $Si-TiO_2$, and the X-ray shielding rate was compared with 0.5 mmPb plate of The shielding rate of shielding of 0.5 mmPb plate 95.92%, 85.26 % based on the case of no shielding under each 60 kVp, 100 kVp tube voltage condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 11 mm or more, and the shielding rate of 100% or more was confirmed at a thickness of 13 mm in 60 kVp condition. When the shielding of $Si-TiO_2$ pad was applied, the shielding rate equal to or greater than 0.5 mmPb plate was obtained at a thickness of 17 mm or more, and a shielding rate of 0.5 mmPb plate was observed at a thickness of 23 mm in 100 kVp condition. Through the results of this study, We could confirm the possibility of manufacturing radiation protective materials that does not contain lead hazard using various metalic compound and liquid Si. This study shows that possibility of liquid Si and other metalic compound can harmonize easily. Beside, It is flexible and strong to physical stress than Pb obtained radiation protective closthes. But additional studies are needed to increase the shielding rate and reduce the weight.

Evaluation of Nondestructive Evaluation Size Measurement for Integrity Assessment of Axial Outside Diameter Stress Corrosion Cracking in Steam Generator Tubes (증기발생기 전열관 외면 축균열 건전성 평가를 위한 비파괴검사 크기 측정 평가)

  • Joo, Kyung-Mun;Hong, Jun-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy600 HTMA tubes has been increasing. As a result, SGs with Alloy600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and abilty of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.

Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping (압전감쇠를 통한 압전단일패널의 전달 소음저감성능)

  • 이중근;김재환;김기선;이형식
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • The possibility of a noise reduction of piezoelectric single Panels is experimentally studied. Piezoelectric single panel is basically a plate structure on which piezoelectric patch with shunt circuit is mounted. The use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. Piezo-damping is implemented by using a newly proposed tuning method. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. By measuring the electrical impedance at the piezoelectric patch bonded on a structure, an equivalent electrical model is constructed near the system resonance frequency. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of single Panel is tested on an acoustic tunnel. The tunnel is a tube with a square cross section and a loud speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across Panels is measured. By enabling the piezoelectric shunt damping noise reduction is achieved at the resonance frequencies as well. Piezoelectric single panel with piezoelectric shunt damping is a promising technology for noise reduction in a broadband frequency.

  • PDF

An FSI Simulation of the Metal Panel Deflection in a Shock Tube Using Illinois Rocstar Simulation Suite (일리노이 록스타 해석환경을 활용한 충격파관 내 금속패널 변형의 유체·구조 연성 해석)

  • Shin, Jung Hun;Sa, Jeong Hwan;Kim, Han Gi;Cho, Keum Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.361-366
    • /
    • 2017
  • As the recent development of computing architecture and application software technology, real world simulation, which is the ultimate destination of computer simulation, is emerging as a practical issue in several research sectors. In this paper, metal plate motion in a square shock tube for small time interval was calculated using a supercomputing-based fluid-structure-combustion multi-physics simulation tool called Illinois Rocstar, developed in a US national R amp; D program at the University of Illinois. Afterwards, the simulation results were compared with those from experiments. The coupled solvers for unsteady compressible fluid dynamics and for structural analysis were based on the finite volume structured grid system and the large deformation linear elastic model, respectively. In addition, a strong correlation between calculation and experiment was shown, probably because of the predictor-corrector time-integration scheme framework. In the future, additional validation studies and code improvements for higher accuracy will be conducted to obtain a reliable open-source software research tool.

Comparative Studies on Serological Tests for Actinobacillus pleuropneumoniae Infection in Swine (돼지에서 Actinobacillus pleuropneumoniae의 혈청학적 진단법에 대한 비교연구)

  • 심항섭;우종태;조중현;전무형
    • Korean Journal of Veterinary Service
    • /
    • v.17 no.2
    • /
    • pp.95-113
    • /
    • 1994
  • To establish an effective diagnostic measure for detection of the antibodies against Actinobacillus pleuropneumoniae, the methods for tube agglutination test (TAT), plate agglutination test (PAT), micro-agglutination test(MAT) and agar-gel immunodiffusion test(ID) were improved and standarized, and the comparative studies were carried out. The results obtained through the experiments were summarized as follows. 1. The rabbit hyperimmune sera to reference serotypes 1 to 6 were cross-tested with TAT, PAT, MAT and ID. In the homologous systems, the range of antibody titers in TAT was 80 to 640, showing the cross-reaction in serotypes 3, 4, 5 and 6. The range of antibody titers in PAT was 4 to 64, showing the cross-reaction in serotypes 3, 4, 5 and 6. In ID, the range of antigen titers was 8 to 32, and cross-reaction was observed in serotype 5. 2. The optimal concentration of antigen in PAT and MAT were 100mg /ml and 1.25mg /ml respectively. The most sensitive reaction in MAT was observed in 52$^{\circ}C$ for 18hrs. 3. In ID, the most promising antigen and the buffer for agar-gel were EDTA-treated antigen and 0.05M tris buffer (pH 7.2), respectively. 4. By the tests for 200 swine sera, it was found that the frequency of positive reaction were 203 in TAT, 240 in PAT and 163 in ID. 5. When compared the titers of TAT with those of MAT for 200 swine sera, MAT showed the higher titer than TAT being increased by relative correlation. Int was found that the titer for positive readings were 20 in TAT and 40 in MAT. 6. when compared the results of ID with those of TAT for 200 swine sera, all sera with TAT titer under 10 were negative in ID. Of the sera with TAT titer 20 and 40, 55.1% nd 91.8% were positive in ID, respectively. All sera with TAT titer above 80 were positive in ID. In comparison of ID and MAT, all sera with MAT titer under 20 were negative in ID. Of the sera with MAT titer 40 and 80, 24.7% and 93.9% were positive in ID, respectively. All sera with MAT titer over 160 showed positive in ID. 7. In conclusion, the established MAT showed high sensitivity but low specificity, wherease ID revealed low sensitivity but high specificity.

  • PDF