• 제목/요약/키워드: tube method

검색결과 2,760건 처리시간 0.027초

상계해법과 유한요소법을 이용한 스피닝공정 해석에 관한 연구 (A Study on the Process of Tube End Spining by the Upper bound Method and Finite Element Method)

  • 김진형;홍성인;이영선
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1996년도 춘계학술대회논문집
    • /
    • pp.23-30
    • /
    • 1996
  • The purpose of this study was to investigate changes in thewall thickness of tube sinking and working forces by the upper bound method and ABAQUS code. The independent variables were : Workpiece material, original wall thickness of tube, die angle, friction, and diameter reduction. The results indicated that of these five variables were a factor in wall-thickness increase and working forces. Three variables, a inner tube wall angle and two angles of the velocity discontinuous surfaces, are optimized in this proposed velocity field by the upper bound method. In this method, we can estimate the working forces and final tube thicknesses whcih are similar to acturla forming process. Optimized process variables which are obtained by upper bound method are used in ABAQUS pre-model . In ABAQUS analysis, the stress and the strain contours which are considered to be heat generation occured by the friction during forming process are observed.

  • PDF

중수로 압력관의 크리프 처짐 해석 기법 및 프로그램 개발 (Development of Creep Deflection Analysis Method and Program for CANDU Pressure Tube)

  • 심도준;허남수;박보규;장윤석;김윤재;김영진;정현규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.66-71
    • /
    • 2004
  • Estimation of the CANDU pressure tube deflection is important since the deflection may cause significant structural failure due to hydrogen diffusion and blister. However, there is no appropriate engineering model to estimate it exactly. The purpose of this paper is to propose a new analysis method and program to resolve this issue. For development of proper analysis method, a series of finite element analyses has been carried under elastic-creep condition. In addition, for effective estimation of the creep deflection, an analysis program named PC-DAS was developed based on the proposed method. Comparison of simple case study results with corresponding reference ones showed good agreement. Therefore, the proposed method and program can be utilized as one of valuable toolkit for integrity assessment of CANDU pressure tube.

  • PDF

Charcoal Tube에 의(依)한 작업환경중(作業環境中) Toluene 함량(含量)에 관(關)한 연구(硏究) (Toluene Determination in Workplace by Charcoal Tube Method)

  • 김형석;구도서;박양원;이정환
    • Journal of Preventive Medicine and Public Health
    • /
    • 제16권1호
    • /
    • pp.193-198
    • /
    • 1983
  • In the determination of organic solvents in workplaces direct reading tube method have been used in Korea for decades. But this method is less accurate and couldn't measure TWA(Time Weighted Average) for 8 hours. Authors tried to detect Toluene concentration in S factory by using charcoal tube according to NIOSH method. The concentration was 158.8ppm. We propose this charcoal tube method should be substituted to get accurate results and to protect employee in workplaces related with solvents.

  • PDF

차음시트의 음향투과손실 측정에 관한 연구 (A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets)

  • 이동훈;강문;이주원;정갑철;권영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

C-arm 각도 변화에 따른 피폭선량 비교 (Comparison of Exposure dose according to the C-arm Angle Change)

  • 신성규
    • 한국콘텐츠학회논문지
    • /
    • 제11권9호
    • /
    • pp.453-458
    • /
    • 2011
  • 본 연구는 C-arm의 각도 변화에 따라 술자의 피폭선량의 변화를 알아보고자 시행 하였다. 실험방법은 101kvp, 4.9mA로 고정하고 조사시간을 3초와 5초로 나누어 시행 하였으며 C-arm Tube를 under와 over로 위치시켜 각각 -30도에서 0, 30, 60, 90도로 변화를 주어 5회 측정하여 평균값을 구하였다. 검출기는 C-arm을 조작하는 방사선사의 위치에서 지면으로부터 160cm의 높이에서 측정하였다. 결과는 -30도에서 측정치가 가장 높았고 0, 30, 60, 90도 순으로 낮았으며 under보다 over tube 방식에서 높았다. 그러므로 방사선사의 피폭선량 저감을 위해서는 over tube 방식보다는 under tube 방식을 사용하고 각도에 변화를 줄 때에는 tube가 술자로부터 멀어지는 각도를 사용하고 가능하다면 조사시간을 단축하는 것이 같은 영상을 만들 수 있으면서도 피폭을 줄일 수 있는 방안이다.

Comparison of Analysis Methods for Ammonia from Swine Production Facilities

  • Kim, Ki Y.;Choi, Hong L.;Kim, Chi N.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1608-1614
    • /
    • 2004
  • This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of $NH_{3}$ emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998($R^{2}$) in the swine confinement house and 94% and 0.997($R^{2}$) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957($R^{2}$) in the swine confinement house and 82% and 0.941($R^{2}$) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube.

기관 협착에서 Long T-tube의 삽입 방법 (A technique for insertion of a long T-tube in tracheal stenosis)

  • 백만종
    • Journal of Chest Surgery
    • /
    • 제26권8호
    • /
    • pp.664-666
    • /
    • 1993
  • A technique for insertion of a long silicone T-tube in patient with critical stenosis and high-risk resection and primary anastomosis of long segment of the distal trachea is presented. It was not easy to insert a long T-tube by existing methods because of flexibility of a T-tube and tightness of stenosis. So we used a silastic endotracheal tube and guiding wire as stylet of a T-tube. During insertion, ventilation was normally maintained through the lumen of endotracheal tube. This provided rapid relief from airway obstruction and asphyxation and is a easy, safe and effective method to restore patency of the major airways.

  • PDF

비부착형 포스트텐션 구조의 모델링기법 (Modeling Technologies for Unbonded Post-Tension Systems)

  • 강현구;나창순
    • 한국전산구조공학회논문집
    • /
    • 제24권1호
    • /
    • pp.33-41
    • /
    • 2011
  • 본 연구에서는 비부착형 포스트텐션 시스템의 해석에 적용할 수 있는 모델링기법을 제시하였다. 모델링은 유한요소 해석 프로그램을 이용하였으며, tube-to-tube contact 요소를 도입하여 강연선의 물리적 형상을 직접적으로 모델링하는 방법과 실제의 강연선 외에 가상의 강연선을 콘크리트에 매입하고, 두 개의 강연선을 스프링으로 연결하여 간접적으로 모델링하는 방법을 동시에 제시하고 비교하였다. 콘크리트의 인장경화 현상을 무시하였을때 두 모델링기법에서는 거의 동일한 결과를 제공하지만 콘크리트의 인장경화를 고려한 경우에는 스프링을 이용한 간접적인 모델링기법을 통해서만 결과를 얻을 수 있었으며, 결과 또한 콘크리트의 경화현상을 고려하지 않은 경우와 다소 상이하였다. 비교를 통하여 비부착형 포스트텐션 시스템의 모델링기법으로 스프링을 이용한 모델링기법을 최종적으로 선정하고 기존의 실험적 연구에서 인용한 실험결과와 해석결과를 비교, 검증하였으며 또한 파라미터 스터디를 통해서 모델링의 적절성을 확인하였다.

Validity of the vertical tube-shift method in determining the relationship between the mandibular third molar roots and the inferior alveolar nerve canal

  • Arora, Anjana;Patil, Bharati A.;Sodhi, Amandeep
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권2호
    • /
    • pp.66-73
    • /
    • 2015
  • Objectives: To assess the validity of the vertical tube-shift method using intraoral periapical radiography (IOPAR) for determining the relationship between the mandibular third molar roots and the inferior alveolar nerve (IAN) canal in comparison with cone-beam computed tomography (CBCT). Materials and Methods: Fifty impacted mandibular third molars were analyzed using the IOPAR vertical tube-shift method and CBCT. The relationship of the IAN canal to the impacted mandibular third molar was recorded as buccal, lingual or in line with the apex and was compared with CBCT findings. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the vertical tube-shift method in depicting the relationship (buccal/lingual/in line with the apex) of the IAN canal to the third molar root apex was calculated. Results: The sensitivity and specificity PPV and NPV of the IOPAR vertical tube-shift technique was found to be highest for a lingual relationship (100%) followed by buccal (94.4%, 92.3%, 97.1%, and 85.7%) and in line with the apex relationship (88.9%, 95.0%, 80.0%, and 97.4%) of the IAN canal with the third molar root apex, respectively. A statistically significant association was observed between the IOPAR vertical tube-shift method and the CBCT with a P-value <0.01. Conclusion: The vertical tube-shift method can be used as an effective diagnostic tool in assessing the relationship of the IAN canal to the third molar root apex with high sensitivity, specificity, PPV, and NPV.

모세관 변경에 따른 가정용 소형 멀티 냉동시스템의 성능에 관한 연구 (A Study on the Performance of a Domestic Small Multi Refrigerator According to a Capillary Tube Change)

  • 김상욱;이무연
    • 대한기계학회논문집B
    • /
    • 제29권6호
    • /
    • pp.763-771
    • /
    • 2005
  • This paper is an experimental study on the performance according to a capillary tube diameter and length in a domestic small multi refrigerator[kimchi refrigerator]. Pressure drop in a capillary tube is predicted by theoretical analysis and experimental method as the reduction of capillary tube diameter from 0.74 to 0.6 mm. The differences between experimental results and analytical results are mainly caused by friction factor in a capillary tube. Because there are no adequate equations used to calculate pressure drop of capillary tube diameter under 1.0mm. The empirical equations necessary for interpretation of capillary tube were derived from capillary tube test results data using curve fitting method. This study shows that the optimized designs of system, which is capillary tube length and refrigerant charge amount, are 2000mm, 83g at the capillary tube diameter 0.6mm and 3000mm, 73g at the capillary tube diameter 0.74mm. And capillary design tools and system matching techniques necessary for development of the kimchi refrigerator were also developed through this study.