• Title/Summary/Keyword: transmission power

Search Result 5,783, Processing Time 0.032 seconds

Throughput Performance of Hybrid ARQ Ultra-Wideband Communication System for Wireless Packet Transmission (무선 패킷 전송을 위한 Hybrid ARQ 광대역 통신시스템의 처리율 성능)

  • Roh, Jae-Sung
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.3
    • /
    • pp.274-280
    • /
    • 2007
  • An ultra-wideband signal is characterized by a radiated spectrum with wide bandwidth around a relatively low center frequency. In this paper, the bit error rate (BER), packet error rate (PER), and data throughput performance for an ultra-wideband system with M-ary correlation receiver are analyze in additive white Gaussian noise (AWGN) and co-channel interference channel. To evaluate the performance of UWB system, a set of UWB communication waveform as pulse position modulated (PPM) signals consisting of more than one UWB pulse is used. The M-ary PPM signals are defined to be equally correlated in order to simplify the system performance analysis. The analysis for system performance shows that the wireless channel error significantly degrades throughput performance and can be effectively increased by hybrid ARQ scheme. Also, an attempt for comparing the data throughput of ultra-wideband system on different performance improvement schemes and parameters has been made. From the performance evaluation process, it is shown that the effects of wireless channel and hybrid ARQ scheme for ultra wideband M-ary PPM system can be evaluated by means of a suitable combination of the PER, throughput vs. signal-to-noise power ratio per bit.

  • PDF

Implementation and Evaluation of Chair-type ECG Monitoring System using Unconstraint Electrode (무구속 전극을 이용한 의자형 심전도 모니터링 시스템의 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.56-62
    • /
    • 2015
  • In this study, we implemented an unconstraint ECG monitoring system on a chair. Nowadays, modern people spend most of their time sitting on the chair. Therefore, it is necessary to have an unconstraint ECG monitoring system that can be used for a long time. The implemented system can perform measurement even with clothes on and it has great advantage on motion artifacts. A pair of unconstraint electrodes are placed on the back of the chair. Amplifier and filters are designed to remove motion artifacts, The baseline noise and power line noise are filtered and very low level of bio-signal is amplified to give a final measurement. Control unit and wireless transmission unit are implemented. Analog signal is converted into digital signal and transmits biological signal to the PC and the smart phone. Therefore continuous ECG monitoring in daily life is made possible. A comparison experiment between Ag / AgCl electrode and unconstraint electrode is conducted to evaluate the performance of the implemented system. As a result, we confirm our unconstraint system can be used for daily life ECG monitoring.

Population Dynamics of Jellyfish Aurelia aurita (s.l.) in Sihwa Lake (시화호에서 보름달물해파리 Aurelia aurita (s.l.)의 개체군변동)

  • Hong, Hyun-Pyo;Han, Chang-Hoon;Yoo, Jeong-Kyu
    • Ocean and Polar Research
    • /
    • v.35 no.3
    • /
    • pp.205-217
    • /
    • 2013
  • We investigated the population dynamics of Aurelia aurita in Sihwa Lake from April to October in 2009. Salinity ranged from 5.9 to 30.7 psu at the surface. Abundance of mesozooplankton ranged from 3 to 111,874 indiv. $m^{-3}$. Ephyrae occurred from April to May with the peak in abundance occurring on 17 April. Maximum density of ephyrae was observed near the power transmission towers that are known to be habitats of polyps. Mortality of ephyrae was lower than in other areas because of the abundant prey concentration and the absence of predators. Young medusae occurred from April to July with the peak in abundance occurring on 8 May. Adult medusae occurred from May to July with the peak in abundance on 25 June and they disappeared before the rainy season. Planula occurred only in May and June with the peak in abundance on 25 June. Growth rates of Aurelia aurita ranged from -0.06 to 0.34 $d^{-1}$, and decreased rapidly after May. The period in which adult medusa occurred was restricted, compared with those in other area in Korea (e.g., Masan Bay) and Japan (e.g., Tokyo Bay). In the period of this study, the available food was limited in June and salinity decreased to ca. 20 psu in May because of the beginning of the wet season. We assumed that the exceptionally short period of occurrence of the medusa may be a response of adults to changes in temperature, salinity or food limitation which leads to the precocious maturation of young medusa and the release of planula and that the brief occurrence of medusa was caused by an abrupt decrease in activity after the release of planula.

A study on the receiving rate of the data of the hybrid communication system using data transfer methods for controller system of navigational aids (데이터 전송방식에 따른 항로표지 관리용 하이브리드 통신 시스템의 수신율 분석에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.78-85
    • /
    • 2014
  • The Mu-communication board supported by hybrid communication is designed with Cortex M3, which is a low power energy consumption 32-bit microcontroller. The Cortex M3 microcontroller has UART(Universal asynchronous receiver/transmitter) ports which can set appropriately using the command line interpreter (CLI) program with each port. URAT ports are used for hybrid communication modems, GPS modules, etc. When the socket type was compared with the short message service type, the socket type was proven to be better. By improving the receiving performance in the control and management system of the AtoN, data loss was minimized. During the testing of the socket and SMS, data was collected from each buoy for 12 hours every 1 minute and the receiving rate of the data was found to be more than 98.58 % and 99.42 % respectively.

Effects of Adjacent Channel Leakage on an Energy Detection Based Spectrum Sensing (인접 채널 누설이 에너지 검파 기반 스펙트럼 센싱에 미치는 영향)

  • Lim, Chang Heon;Kim, Hyung Jung;Kim, Chang Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.5
    • /
    • pp.542-547
    • /
    • 2014
  • When a primary user transmits over some frequency band assigned to it, most of its transmission power tends to be concentrated in the band but a small portion of it spreads into the adjacent bands. Thus the false alarm probability for the adjacent bands can be higher than expected, even though no primary users are active in the bands. A previous work evaluated the effects of the adjacent channel leakage on the performance of an energy detection based spectrum sensing but it did not take into account the fading phenomenon. In this paper, we analyze the effects of the adjacent channel leakage on an energy detection based spectrum sensing scheme in terms of detection probability and false alarm probability in a fading environment.

Implementation of Implantable Bluetooth Bio-telemetry System for Transmitting Acoustic Signals in the Body with Wireless Recharging Function (무선 충전 가능한 블루투스 방식의 체내 음향신호 전송용 이식형 바이오 텔레메트리 시스템 구현)

  • Lee, Sang-June;Kim, Myoung Nam;Lee, Jyung Hyun;Lim, Hyung-Gyu;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.5
    • /
    • pp.652-662
    • /
    • 2015
  • It is necessary to develop small, implantable bio-telemetry systems which can measure and transmit patients' bio-signals from internal body to external receiver. When measuring bio-signals, like electrical bio-signals, acoustic bio-signal measurement has also a big clinical usefulness. But, sound signal has larger frequency bandwidth than any other bio-signals. When considering these issues, a wireless telemetry system which has rapid data transmission rate proportional to wide frequency bandwidth is necessary to be developed. The bluetooth module is used to overcome the data rate limitation caused by the large frequency bandwidth. In this paper, a novel multimedia bluetooth biotelemetry system was developed which consists of transmitter module located in the body and receiver device located outside of the body. The transmitter consists of microphone, bluetooth, and wireless charging device. And the receiver consists of bluetooth and codec system. The sound inside the skin is captured by microphone and sent to receiver by bluetooth while charging. The wireless charging system constantly supplies the electric power to the system. To verify the performance of the developed system, an in vitro experiment has been performed. The results show that the proposed biotelemetry system has ability to acquire the sound signals under the skin.

Improved cluster-based routing protocol using cluster header in Mobile ad hoc network (모바일 애드혹 네트워크에서 클러스터 헤드를 이용한 향상된 클러스터 기반 라우팅 프로토콜)

  • Kim, Chang-Jin;Kim, Wu-Woan;Jang, Sang-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.241-244
    • /
    • 2012
  • In mobile ad-hoc networks, it should be the most important issue to reduce the power consumption of communications, because the resource of a node is limited in these networks. In existing cluster-based routing protocols, cluster headers participate in almost all communication processes. Therefore the lifetime of the cluster header is shortened and it does not have the effective route. In the proposed cluster-based routing protocol, the cluster header transmits a control packet which gives the route information to member nodes. This makes that the cluster header decreases the number of participating in communications, and that node members do not have to communicate trough the cluster header. This results in extending the lifetime of the cluster header, and having the effective route, data transmission rate and improved stability of routes.

  • PDF

Environment Monitoring System Using RF Sensor (RF 센서를 이용한 해양 환경 관리 시스템)

  • Cha, Jin-Man;Park, Yeoun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.896-898
    • /
    • 2012
  • Recently, many countries are making efforts for the development of ocean resources because the necessity and importance of the ocean resources are increased. Underwater sensor networks have emerged as a very powerful technique for many applications, including monitoring, measurement, surveillance and control and envisioned to enable applications for oceanographic data collection, ocean sampling, environmental and pollution monitoring, offshore exploration, disaster prevention, tsunami and seaquake warning, assisted navigation, distributed tactical surveillance, and mine reconnaissance. The idea of applying sensor networks into underwater environments (i.e., forming underwater sensor networks) has received increasing interests in monitoring aquatic environments for scientific, environmental, commercial, safety, and military reasons. The data obtained by observing around the environment are wireless-transmitted by a radio set with various waves. According to the technical development of the medium set, some parameters restricted in observing the ocean have been gradually developed with the solution of power, distance, and corrosion and watertight by the seawater. The actual matters such as variety of required data, real-time observation, and data transmission, however, have not enough been improved just as various telecommunication systems on the land. In this paper, a wireless management system will be studied through a setup of wireless network available at fishery around the coast, real-time environmental observation with RF sensor, and data collection by a sensing device at the coastal areas.

  • PDF

Impact of Channel Estimation Errors on SIC Performance of NOMA in 5G Systems (5G 시스템에서 비직교 다중접속의 SIC 성능에 대한 채널 추정 오류의 영향)

  • Chung, Kyuhyuk
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.9
    • /
    • pp.22-27
    • /
    • 2020
  • In the fifth generation (5G) networks, the mobile services require much faster connections than in the fourth generation (4G) mobile networks. Recently, as one of the promising 5G technologies, non-orthogonal multiple access (NOMA) has been drawing attention. In NOMA, the users share the frequency and time, so that the more users can be served simultaneously. NOMA has several superiorites over orthogonal multiple access (OMA) of long term evolution (LTE), such as higher system capacity and low transmission latency. In this paper, we investigate impact of channel estimation errors on successive interference cancellation (SIC) performance of NOMA. First, the closed-form expression of the bit-error rate (BER) with channel estimation errors is derived, And then the BER with channel estimation errors is compared to that with the perfect channel estimation. In addition, the signal-to-noise (SNR) loss due to channel estimation errors is analyzed.

The Design of the Ternary Sequential Logic Circuit Using Ternary Logic Gates (3치 논리 게이트를 이용한 3치 순차 논리 회로 설계)

  • 윤병희;최영희;이철우;김흥수
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.10
    • /
    • pp.52-62
    • /
    • 2003
  • This paper discusses ternary logic gate, ternary D flip-flop, and ternary four-digit parallel input/output register. The ternary logic gates consist of n-channel pass transistors and neuron MOS(νMOS) threshold inverters on voltage mode. They are designed with a transmission function using threshold inverter that are in turn, designed using Down Literal Circuit(DLC) that has various threshold voltages. The νMOS pass transistor is very suitable gate to the multiple-valued logic(MVL) and has the input signal of the multi-level νMOS threshold inverter. The ternary D flip-flop uses the storage element of the ternary data. The ternary four-digit parallel input/output register consists of four ternary D flip-flops which can temporarily store four-digit ternary data. In this paper, these circuits use 3.3V low power supply voltage and 0.35m process parameter, and also represent HSPICE simulation result.