• 제목/요약/키워드: transmission line parameters

검색결과 289건 처리시간 0.026초

뉴로-퍼지기법을 이용한 송전선로의 고장검출 (Fault Detection of Transmission Line using Neuro-fuzzy Scheme)

  • 전병준;박철원;신명철;이복구;권명현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1046-1049
    • /
    • 1998
  • This paper deals with the new fault detection technique for transmission line using Neuro-fuzzy Scheme. Neuro-fuzzy Scheme is ANFIS(Adaptive-network Fuzzy Inference System) based on fusion of fuzzy logic and neural networks. The proposed scheme has five layers. Each layer is the component of fuzzy Inference system and performs different action. Using learning method of neural network, fuzzy premise and consequent parameters is tuned properly.

  • PDF

ANALYSIS OF THE MUTUAL SELF-BIASED SHIELDED MAGNETO-RESISTIVE HEAD WITH TRANSMISSION-LINE MODEL(I)

  • Zhang, H.W.;Kim, H.J.
    • 한국자기학회지
    • /
    • 제5권4호
    • /
    • pp.294-298
    • /
    • 1995
  • A shielded magnetoresistive (SMR) head which has double MR films and linearizes each other has been designed and studied by applying the transmission-line model. We have analyzed the yoke efficiency, bias efficiency and read efficiency of the SMR head. The read efficiency strongly depends on the height of the sensor and slightly on the other geometric parameters. The yoke and bias efficiencies vary with gap length, insulated layer thickness and relative permeability. A quasi-index reduction in the signal flux is observed when the displacement moves away from the medium.

  • PDF

적응형 퍼지 시스템에 의한 송전선로보호의 고장검출 계전기법 (Fault Detection Relaying for Transmission line Protection using ANFIS)

  • 전병준
    • 한국지능시스템학회논문지
    • /
    • 제9권5호
    • /
    • pp.538-544
    • /
    • 1999
  • 본 논문에서는 송전선로의 보호를 위하여 적응형 퍼지 시스템을 도입하여 고장 유형 판별부와 고장점 추정부의 두 부분으로 구성된 새로운 고장검출기법을 개발하였다. 제안된 시스템의 퍼지 입력변수로는 전류의 정상분과 영상분 그리고 실효치를 선정하였으며 신경회로망의 학습방법에 의하여 전건부와 후건부가 적절하게 조정되었다. 제시된 기법의 효용성을 입증하기 위하여 전자과도 해석 프로그램인 EMTP로부터 수집된 데이터를 활용하였다. 시뮬레이션 결과 제안된 기법은 고장유형이 정확하게 판별되었으며 고장점 추정이 개선되었다.

  • PDF

양극산화 알루미나 기반의 DRAM 패키지 기판 (Anodic Alumina Based DRAM Package Substrate)

  • 김문정
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.853-858
    • /
    • 2010
  • 본 논문은 알루미늄의 양극산화를 통하여 알루미나(Alumina, $Al_2O_3$)를 형성함으로써 알루미나 및 알루미늄의 적층 구조 DRAM 패키지 기판을 구현하였다. 전송선 기반의 설계를 적용하기 위해 2차원 전자장 시뮬레이션을 수행하였다. 분석 결과를 바탕으로 새로운 기판에 적용할 신호선의 폭 및 간격과 알루미나 두께 등의 설계인자를 최적화하였다. 테스트 패턴 제작 및 측정을 통해 설계인자를 검증하였으며, 이를 바탕으로 설계 룰(Design rule)을 정하고 패키지의 개념 설계 및 상세 설계를 진행하여 DDR2 DRAM 패키지 기판을 성공적으로 제작하였다.

MRAM read와 write line의 S-parameter 해석 (S-parameter Analysis for Read and Write Line of MRAM)

  • 박승영;조순철
    • 한국자기학회지
    • /
    • 제13권5호
    • /
    • pp.216-220
    • /
    • 2003
  • 본 연구에서는 MRAM(magnetic random access memory)이 10 GHz까지 높은 주파수에서 동작할 때 쓰기 신호와 읽기 신호가 얼마나 효율적으로 전달되는지 계산하였다. 이를 위해 읽기와 쓰기에 필요한 도선이 있는 시편을 3차원으로 모델링하였다. 모의실험은 쓰기 동작과 읽기 동작으로 나눠서 수행되었고, FEM(finite element method) 알고리즘을 이용하여 S-parameter를 출력하였다. 계산된 결과를 이용하여 실험적으로 설계된 MRAM 시편의 쓰기와 읽기 동작에서 전송계수 S$_{21}$을 각각 DC에서 1 GHz 그리고 100 GHz 까지의 영역에서 해석하였다. 또한 각각의 길이가 600 $\mu$m인 bit line과 sense line사이의 절연체 두께를 500에서 1500$\AA$으로 변화시켰을 때, 3 dB 감쇄 주파수를 135에서 430 MHz까지 약 3.3배 높일 수 있었다. 그리고 계산된 S-parameter를 이용하여 전달 지연을 계산하여 접근시간을 예측하였다.

한전의 새로운 낙뢰측정 네트워크 KLDNet (The new lightning detection system of KEPCO Lightning Detection & information Network)

  • 우정욱;곽주식;심응보;원봉주;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.83-84
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the shut down of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. A lightning detection system, LPATS, has been operated since 1995 in KEPCO. For the improved detection efficiency, we had in stalled the new lightning detection network named as KLDNet in 2005. Also, we had developed the new software for the lightning parameters analysis and real time information service on the WEB. In this paper, we would like to introduce about the new system.

  • PDF

Study on the Thermal Transient Response of TSV Considering the Effect of Electronic-Thermal Coupling

  • Li, Chunquan;Zou, Meng-Qiang;Shang, Yuling;Zhang, Ming
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권3호
    • /
    • pp.356-364
    • /
    • 2015
  • The transmission performance of TSV considering the effect of electronic-thermal coupling is an new challenge in three dimension integrated circuit. This paper presents the thermal equivalent circuit (TEC) model of the TSV, and discussed the thermal equivalent parameters for TSV. Si layer is equivalent to transmission line according to its thermal characteristic. Thermal transient response (TTR) of TSV considering electronic-thermal coupling effects are proposed, iteration flow electronic-thermal coupling for TSV is analyzed. Furthermore, the influences of TTR are investigated with the non-coupling and considering coupling for TSV. Finally, the relationship among temperature, thickness of $SiO_2$, radius of via and frequency of excitation source are addressed, which are verified by the simulation.

등가 전력선을 가진 Chua 회로에서의 카오스 동기화 (Chaos Synchronization using Chua Circuit with Equivalent Power Line)

  • 배영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.259-262
    • /
    • 2000
  • Chua's circuit is a simple electronic network which exhibits a variety of bihucation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed anti synchronizations of a equivalent power line are investigated. Since the synchronization of the equivalent power line system is impossible by coupled synchronization, theory having both the drive-response and the coupled synchronization is proposed. Af a result, the chaos synchronization has delay characteristics in the equivalent power line transmission system caused by the line parameters L and C.

  • PDF

4포트 커넥터 시스템의 등가회로 변환에 관한 연구 (Equivalent Circuit Model for Four Port Connector System)

  • 심민규;김종민;나완수
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.

Complexity Reduction Algorithm of Speech Coder(EVRC) for CDMA Digital Cellular System

  • Min, So-Yeon
    • 한국멀티미디어학회논문지
    • /
    • 제10권12호
    • /
    • pp.1551-1558
    • /
    • 2007
  • The standard of evaluating function of speech coder for mobile telecommunication can be shown in channel capacity, noise immunity, encryption, complexity and encoding delay largely. This study is an algorithm to reduce complexity applying to CDMA(Code Division Multiple Access) mobile telecommunication system, which has a benefit of keeping the existing advantage of telecommunication quality and low transmission rate. This paper has an objective to reduce the computing complexity by controlling the frequency band nonuniform during the changing process of LSP(Line Spectrum Pairs) parameters from LPC(Line Predictive Coding) coefficients used for EVRC(Enhanced Variable-Rate Coder, IS-127) speech coders. Its experimental result showed that when comparing the speech coder applied by the proposed algorithm with the existing EVRC speech coder, it's decreased by 45% at average. Also, the values of LSP parameters, Synthetic speech signal and Spectrogram test result were obtained same as the existing method.

  • PDF