• Title/Summary/Keyword: transmission distribution

Search Result 1,533, Processing Time 0.03 seconds

Effect of Non-uniform Perforation and Extended Inlet/outlet Length in the Concentric Resonator on the Transmission Loss (동심관형 공명기의 천공 분포 및 연장관이 전달 손실에 미치는 특성 해석)

  • Lee, Seong-Hyun;Ih, Jeong-Guon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.114-117
    • /
    • 2005
  • In the reactive concentric resonator, perforated inner tubes are widely used for various purposes related to noise reduction, flow guiding, and structural aspects. Perforation distribution patterns influence both the acoustic performance and mechanical performance. In this study, the influence of distribution patterns on acoustic performance are explained by adopting the concept of extended inlet/outlet length. Predicted transmission with varying extended inlet/outlet length is compared with prediction by varying distribution patterns. The transmission loss difference due to perforation distribution patterns can be explained by changing the extended inlet/outlet length of the uniformly perforated resonator.

  • PDF

A Study on the Effects of Lightning Arrestors Installment on a 154kV Transmission System (154kV 송전선로용 피뢰기 현장 설치 효과 분석)

  • Choi, Han-Yeol;Gu, Sung-Wan;Min, Byeong-Wook;Park, Soon-Kyu;Lee, Bong-Hee;Kwak, Joo-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.184-189
    • /
    • 2009
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. As sensitive loads and reliance on electric power increase year by year, it is getting more focus on stable and high quality of power supply. To protect the transmission and distribution line from lightning, the transmission lightning arrester can be the effective facility on the power system. This paper discusses Gapped type Arresters application results by analysing effects of lightning arresters on transmission and distribution line.

Study on the effects of lightning arrestors installment on a 154kV transmission system (154kV 송전선로용 피뢰기 현장 설치 효과 분석)

  • Choi, Han-Yeol;Min, Byeong-Wook;Park, Soon-Kyu;Lee, Bong-Hee;Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.9-11
    • /
    • 2008
  • Lightning has been identified as one of the leading causes of outages on transmission and distribution systems. To protect the transmission and distribution line from lightning, the transmission lightning arrestor can be the effective facility on the power system. This paper will discuss Gapped type Arresters application results by analysing effects of lightning arrestors on transmission and distribution line.

  • PDF

A Practical Voltage Error Correction Technique for Distribution System under Distribution Automation Environment

  • Aslam, Muhammad;Kim, Hyung-Seung;Choi, Myeon-Song;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.669-676
    • /
    • 2018
  • Transmission system has been well studied since long time and power system techniques of distribution system are more or less derived from transmission system. However, unlike transmission systems, many practical issues are encountered in the distribution system. Considerable amount of error is observed in voltage obtained from the Feeder Remote Terminal Units (FRTUs) measured by the pole mounted PTs along the distribution feeder. Load uncertainty is also an issue in distribution system. Further, penetration of Distributed Generators (DGs) creates voltage variations in the system. Hybrid radial/ loop distribution system also make it complicated to handle distribution system. How these constraints to be handled under Distribution Automation (DAS) environment in order to obtain error free voltage is described in this paper and therefore, a new approach of voltage error correction technique has been proposed. The proposed technique utilizes reliable data from substation and the FRTUs installed in DAS. The proposed technique adopts an iterative process for voltage error correction. It has been tested and proved accurate not only for conventional radial systems but also for loop distribution systems.

Sound Transmission Loss of Double Panels(I) : A Double Wall with Air Cavity (이중판의 차음손실 I)

  • 강현주;김현실;김재승;김상렬
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.945-952
    • /
    • 1997
  • This paper shows the feasibility of the suggestion that the angle distribution of incident sound to panels might be gaussian, instead of the conventional uniform distribution in the analysis of transmission loss of panels. To prove the suggestion, the problems with the diffuse sound field in a reverberation room are examined by case studies and the comparision of the prediction with the measurement of sound transmission loss of walls are performed. The results of the comparision show good agreement between the two values.

  • PDF

Bit-map-based Spatial Data Transmission Scheme

  • OH, Gi Oug
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.8
    • /
    • pp.137-142
    • /
    • 2019
  • This paper proposed bitmap based spatial data transmission scheme in need of rapid transmission through network in mobile environment that use and creation of data are frequently happen. Former researches that used clustering algorithms, focused on providing service using spatial data can cause delay since it doesn't consider the transmission speed. This paper guaranteed rapid service for user by convert spatial data to bit, leads to more transmission of bit of MTU, the maximum transmission unit. In the experiment, we compared arithmetically default data composed of 16 byte and spatial data converted to bitmap and for simulation, we created virtual data and compared its network transmission speed and conversion time. Virtual data created as standard normal distribution and skewed distribution to compare difference of reading time. The experiment showed that converted bitmap and network transmission are 2.5 and 8 times faster for each.

Analytical Prediction of Transmission Error and Load Distribution for a Plugin HEV (플러그인 HEV용 변속기전달오차와 하중분포에 관한 연구)

  • Zhang, Qi;Kang, Jae-Hwa;Yun, Gi-Baek;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.116-121
    • /
    • 2012
  • In recent years, world is faced with a transportation energy dilemma, and the transportation is dependent on a single fuel - petroleum. However, Hybrid Electric Vehicle(HEV) technology holds more advantages to reduce the demand for petroleum in the transportation by efficiency improvements of petroleum consumption. Therefore, there is a trend that lower gear noise levels are demanded in HEV for drivers to avoid annoyance and fatigue during operation. And meshing transmission error(T.E.) is the excitation that leads to the tonal noise known as gear whine, and radiated gear whine is also the dominant source of noise in the whole gearbox. This paper presents a method for the analysis of gear tooth profile and lead modification, and the predictions of transmission error and load distribution are shown under one loaded torque for the 1st gear pair of HEV gearbox. The test is also obtained before tooth micro-modification under the torque. At last, the appropriate tooth modification is used to minimize the transmission error and load distribution under the loaded torque. It is a good approach which the simulated result is used to improve the design in order to minimize the radiation gear whine noise.

Implementation of Wireless Distribution Automation System using Binary CDMA Technology (바이너리 CDMA 기술을 이용한 무선 배전 자동화 시스템의 구현)

  • Kwon, Tai-Kil;Cho, Jin-Woong;Hong, Dae-Ki
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.4
    • /
    • pp.239-244
    • /
    • 2012
  • In this paper, we first introduce our own binary CDMA technology. Then we propose a wireless distribution automation system using the binary CDMA technology. The major research items are the binary CDMA distribution automation system, piconet configuration for remote control and monitoring, scheduling for the transmission and reception of data, and ways of applying encryption to protect wireless packet. To verify the possibility of applying wireless transmission to the distribution automation system, we experiment the implemented system in terms of the transmission rate by applying it to a real-world environment.

Analysis of Transmission Power System with Superconducting Fault Current Limiter for Reducing a Fault Current (초전도 한류기 적용을 통한 모의 송전계통의 고장 전류 저감 분석)

  • Kim, Myong-Hyon;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul;Choo, Dong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.718-719
    • /
    • 2011
  • Lately, the demand for electrical power has been significantly increased. As a result a power transmission system has been improved. On the other hand fault current increased more than past. Superconducting fault current limiter (SFCL) is one of the solutions to limit fault current. However, SFCL's research has not advanced in a power transmission system fully. Therefore, we studied effect of SFCL in a power transmission system. The power distribution system is open-loop circuit, but a power transmission system is closed-loop system. Consequently, Fault current in a power transmission system is larger than fault current in a power distribution system. we exerimented a simple closed-loop power transmission system circuit.

  • PDF