Effect of Non-uniform Perforation and Extended Inlet/outlet Length in the Concentric Resonator on the Transmission Loss

동심관형 공명기의 천공 분포 및 연장관이 전달 손실에 미치는 특성 해석

  • 이성현 (한국과학기술원 기계공학과) ;
  • 이정권 (한국과학기술원 기계공학과)
  • Published : 2005.11.17

Abstract

In the reactive concentric resonator, perforated inner tubes are widely used for various purposes related to noise reduction, flow guiding, and structural aspects. Perforation distribution patterns influence both the acoustic performance and mechanical performance. In this study, the influence of distribution patterns on acoustic performance are explained by adopting the concept of extended inlet/outlet length. Predicted transmission with varying extended inlet/outlet length is compared with prediction by varying distribution patterns. The transmission loss difference due to perforation distribution patterns can be explained by changing the extended inlet/outlet length of the uniformly perforated resonator.

Keywords