• 제목/요약/키워드: transient method

검색결과 2,572건 처리시간 0.025초

초기과도 상태를 개선한 자기 동조 제어 방식 (Self-tuning control with improved transient state)

  • 김운성;배한경;허경무
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.376-381
    • /
    • 1992
  • In this thesis, a self-tuning control method based on Variable Structure System technique for tracking control of Direct-Drive motor is presented. The self-tuning control could not make the tracking error zero in the transient period. This tracking error may be due to disturbances or the error in parameter identification. To overcome this problem, a self-tuning control method based on discrete time VSS technique is presented. The STC based on VSS technique gives good tracking performance of the reference signal in the transient period. The proposed controller is robust to parameter errors and disturbances. The performance of the proposed controller is compared with that of simple STC through digital computer simulation.

  • PDF

초고압 $SF_6$가스차단기의 소전류 차단성능 해석기술 II (Evaluation Method II of the Small Current Breaking Performance of SF$_6$-Blown High-Voltage Gas Circuit Breakers)

  • 송기동;이병윤;박경엽;박정후
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권8호
    • /
    • pp.384-391
    • /
    • 2001
  • The insulation strength between contacts after current interruption to the transient recovery voltage i.e., the dielectric recovery strength should be estimated for the evaluation of the small capacitive current interruption capability. Many authors have used theoretical and semi-experimental approaches to evaluate the transient breakdown voltage after the current interruption. Moreover, an empirical equation, which is obtained from a series of tests, has been used to estimated the dielectric recovery strength. Un this paper, the theoretical method which is generated from the streamer theory has been applied to real circuit breakers in order to evaluated the interruption capability. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

가압열충격을 고려한 원자로 압력용기의 파괴역학적 해석 (Fracture Mechanics Analysis of a Reactor Pressure Vessel Considering Pressurized Thermal Shock)

  • 박재학;박상윤
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.29-38
    • /
    • 2001
  • The purpose of this paper is to evaluate the structural integrity of a reactor pressure vessel subjected to the pressurized thermal shock(PTS) during the transient events, such as main steam line break(MSLB) and small break loss of coolant accident(SBLOCA). For postulated surface or subsurface cracks, variation curves of stress intensity factor are obtained by using the three different methods, including ASME section XI code anlysis, the finite element alternating method and the finite element method. From the stress intensity factor curves, the maximum allowable nil-ductility transition temperatures(RT/NDT/) are determined by the tangent criterion and the maximum criterion for various crack configurations and two initial transient events. As a result of the analysis, it is noted that axial cracks have smaller maximum allowable RT$_{NDT}$ values than same-sized circumferential cracks for both the transient events in the case of the tangent criterion. Axial cracks have smaller RT$_{NDT}$ values than same-sized circumferential cracks for MSLB and circumferential cracks have smaller values than axial cracks for SBLOCA in the case of the maximum criterion.

  • PDF

배전계통에 사용되는 봉형 접지전극의 접지 특성 분석 (Grounding Characteristics Analysis of the Rod-Type Grounding Electrodes used for Electric Distribution Systems)

  • 김경철;정지원
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.49-56
    • /
    • 2011
  • Grounding system insures a reference potential point for electric devices and also provides a low impedance path for fault currents or transient currents in the earth. The ground impedance as function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. In this paper, the grounding resistance, grounding impedance and transient grounding impedance are measured by using 3-point fall-of-potential method in order to analyse grounding characteristics of the copper and concrete rod grounding electrodes. An equivalent transfer function model of the ground impedance and transient grounding impedance are identified from the measured values by using ARMA method and evaluated by comparing the conventional grounding impedance.

A Diffraction Transfer Function Approach to the Calculation of the Transient Field of Acoustic Radiators

  • Lee, Chan-Kil
    • ETRI Journal
    • /
    • 제16권1호
    • /
    • pp.1-15
    • /
    • 1994
  • A computationally-efficient approach to the calculation of the transient field of an acoustic radiator was developed. With this approach, a planar or curved source, radiating either continuous or pulsed waves, is divided into a finite number of shifted and/or rotated versions of an incremental source such that the Fraunhofer approximation holds at each field point. The acoustic field from the incremental source is given by a 2-D spatial Fourier transform. The diffraction transfer function of the entire source can be expressed as a sum of Fraunhofer diffraction pattern of the incremental sources with the appropriate coordinate transformations for the particular geometry of the radiator. For a given spectrum of radiator velocity, the transient field can be computed directly in the frequency domain using the diffraction transfer function. To determine the accuracy of the proposed approach, the impulse response was derived using the inverse Fourier transform. The results obtained agree well with published data obtained using the impulse response approach. The computational efficiency of the proposed method compares favorably to those of the point source method and the impulse response approach.

  • PDF

Development of a Simulation Method of Surge Transient Flow Phenomena in a Multistage Axial Flow Compressor and Duct System

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권4호
    • /
    • pp.189-199
    • /
    • 2013
  • A practical method of surge simulation in a system of a high-pressure-ratio multistage axial flow compressor and ducts, named SRGTRAN, is described about the principal procedures and the details. The code is constructed on the basis of one-dimensional stage-by-stage modeling and application of fundamental equations of mass, momentum, and energy. An example of analytical result on surge behaviors is included as an experimental verification. It will enable to examine the transient flow phenomena caused by possible compressor surges and their influences on the system components in plant systems including high-pressure-ratio axial compressors or gas turbines.

다중 제어 시스템의 스위칭 특성을 이용한 과도 응답 개선 (The Improvement of the transient Response Using the Switching Property of Multiple Control Systems.)

  • 이형찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1100-1103
    • /
    • 1996
  • A well-known problem in adaptive control is the poor transient response which is observed when adaptation is initiated. This paper proposes a useful method to improve the transient response of adaptive control systems by using multiple models of the plant and switching mechanism by fuzzy inference. The models are identical except for initial estimates of the unknown plant parameteres. The control input to be applied is determined at every instant by the model which best approximates the plant. Simulation results are presented to indicate the performance improvement of adaptive control systems using the proposed method.

  • PDF

과도 안정도를 고려한 수송능력 산정 알고리즘의 개발에 관한 연구(II) (A Study on Development of Power Transfer Capability Calculation Algorithm Considering Transient Stability (II))

  • 김용하;이범;최상규;오석현;조성린;김미예
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.128-130
    • /
    • 2004
  • The cost losing synchronous through a transient instability is extremely high in modem power systems. This paper presents a power transfer capability calculation algorithm considering transient stability. The theoretical development is straightforward: dynamic equations are converted to numerically equivalent algebraic equation and then integrated into the standard formulation for power transfer capability calculation. The proposed method is applied to IEEE-24 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

구조물의 시간에 따른 거동 해석을 위한 유한요소법에 기초한 단일 스텝 시간 범주들의 비교연구 (A Comparative Study on Single Time Schemes Based on the FEM for the Analysis of Structural Transient Problems)

  • 김우람;최윤대
    • 한국군사과학기술학회지
    • /
    • 제14권5호
    • /
    • pp.957-964
    • /
    • 2011
  • New time schemes based on the FEM were developed and their performances were tested with 2D wave equation. The least-squares and weighted residual methods are used to construct new time schemes based on traditional residual minimization method. To overcome some drawbacks that time schemes based on the least-squares and weighted residual methods have, ad-hoc method is considered to minimize residuals multiplied by others residuals as a new approach. And variational method is used to get necessary conditions of ad-hoc minimization. A-stability was chosen to check the stability of newly developed time schemes. Specific values of new time schemes are presented along with their numerical solutions which were compared with analytic solution.

전달강성계수법에 의한 분기형 구조물의 시긴이력응답해석 (Time Historical Response Analysis of Tree Structure by Transfer Stiffness Coefficient Method)

  • 문덕홍;강현석;최명수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.426-431
    • /
    • 1998
  • This, paper describes formulation for time historical response analysis of vibration for tree structure. This method is derived from a combination of the transfer stiffness coefficient method and the Newmark-.betha. method. And This present method improves the computational accuracy of the transient vibration response analysis remarkably owing to several advantages of the transfer stiffness coefficient method. We regarded the structure as a lumped mass system here. The analysis algorithm for the time historical response was formulated for the tree structure. The validity of the present method compared with the transfer matrix method and the FEM(Finite Element Method) for transient vibration analysis is demonstrated through the numerical computations.

  • PDF