• 제목/요약/키워드: tolerable risk

검색결과 106건 처리시간 0.025초

Risk Graph에 의해 할당된 SIL에 따른 철도 승강장 도어 시스템의 정량적 Risk 저감 모델 (Quantitative Risk Reduction Model according to SIL allocated by Risk Graph for Railway Platform Door System)

  • 송기태;이성일
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.141-148
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. Especially, in case of the SIL allocation method without determining of quantitative tolerable risk, the additional review is needed to check whether it is suitable or not is required. In this study, the quantitative risk reduction model based on the safety integrity allocation results of railway platform screen door system using Risk Graph method has been examined in order to review the suitability of quantitative risk reduction according to allocated safety integrity level.

가연성가스 수송배관에 대한 목표 신뢰도 수준 설정에 관한 연구 (A Study on Establishing Target Reliability Levels for Flammable Gas Transmission Pipelines)

  • 이진한;조영도;문종삼
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.52-58
    • /
    • 2018
  • 신뢰도 기반 접근법(RBDA)에서, 신뢰도 목표는 설계 및 유지관리 단계에서 관계되는 한계상태를 충족할 수 있는 정도의 안전 수준을 가지는 지 확인하기 위해서 사용된다. 우리나라의 경우 가연성 가스 배관에 대한 신뢰도 목표는 아직 개발되거나 활용되지 못하고 있다. 다만 신뢰도 목표 대신에 사회적 위험과 개인적 위험과 같은 위험 측정지표에 대한 허용가능(tolerable) 판단기준이 배관의 위험관리에 적용되어 왔다. 본 논문에서는 고압천연가스 배관에 대한 정량적 위험평가 시 판단기준으로 삼는 사회적, 개인적 위험 판단기준을 사용하여 신뢰도 기반 접근법의 핵심요소인 목표 신뢰도를 개발하는 절차를 소개하고 자 한다. 또한 소개된 절차를 통해 천연가스와 수소가스 수송배관에 대한 신뢰도 목표를 제안한다.

부산 연근해 저서어류 체내의 미량금속 분포 특성과 잠재적 인체 위해성 평가 (Distribution and Potential Human Risk Assessment of Trace Metals in Benthic Fish Collected from the Offshore of Busan, Korea)

  • 최진영;김경련
    • 대한환경공학회지
    • /
    • 제37권6호
    • /
    • pp.349-356
    • /
    • 2015
  • 본 연구는 부산연근해에서 서식하는 저서어류 체내의 미량금속에 의한 인체 위해 영향을 정량적으로 평가하기 위하여 수행되었다. 부산의 용호부두 인근에서 채취 된 4종의 식용저서어류 넙치, 우럭, 쥐치, 밑달갱이 조직내의 미량금속(trace metals)의 함량을 ICP-MS를 이용하여 분석하였다. 그리고 이를 토대로 어류섭취를 통한 미량금속의 인체 노출량을 파악하고, 이로 인한 잠재적 인체 위해도 평가를 수행하였다. 4종의 어류 조직 내 미량금속의 평균함량은 Li, Cr, Ni, Cu, Zn, As, Cd, Pb이 각각 $0.005{\pm}0.009$, $0.77{\pm}0.30$, $0.29{\pm}0.34$, $0.49{\pm}0.14$, $15.96{\pm}2.52$, $10.62{\pm}4.67$, $0.001{\pm}0.002$, $0.045{\pm}0.06mg/kgdw$으로 나타났다. 이 지역에서 채취된 어류의 섭취로 인한 표준체중(60 kg)의 국민에 대한 노출평가 결과 Cu, Zn은 PMTDI (provisional maximum tolerable daily intake)의 0.0032, 0.054-0.18%, As, Cd, Pb는 PTWI (provisional tolerable weekly intake)값의 13, 0.0041, 0.020%로 나타나 합동식품첨가물전문가위원회(The Joint FAO/WHO Expert Committee on Food Additives, JFCFA)에서 권고하는 각원소의 제한섭취량에 비하여 매우 낮은 수준이었다. 그리고 독성(비발암)위해도 평가 결과는 모두 HI (hazard index)지수가 1 이하로 장기간 섭취하여도 안전한 것으로 나타났으며, 4종의 모든 어류섭취로 인한 As의 노출로 인한 초과 발암 위해도도 10만명 당 1명 이하로 나타나 역시 장기섭취로 인한 발암 확률도 무시할 만한 수준인 것으로 나타났다.

열차운행선 지장공사에 대한 위험도 평가 연구 (A Study on the Risk Assessment for Works on/near Operating Line)

  • 정도현;왕종배;이수룡
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1515-1524
    • /
    • 2008
  • In this study, railway accidents from constructing or maintaining works on/near operating line were reviewed during 2005-2007 years. Causes and hazards analysis of these accidents was performed to make an accident scenario for risk assessments. And the risk of worker casualty on/near operating line was quantitatively assessed. Also a constitution method of Risk Matrix for manage tolerable risk level was proposed.

  • PDF

한국인의 요오드 섭취와 요오드 상한섭취량 (Iodine Intake and Tolerable Upper Intake Level of Iodine for Koreans)

  • 이현숙;민혜선
    • Journal of Nutrition and Health
    • /
    • 제44권1호
    • /
    • pp.82-91
    • /
    • 2011
  • The present study reviewed the effects of excess iodine intake on thyroid function and the incidence of thyroid disease and discussed the scientific basis for establishing a tolerable upper intake level (UL) of iodine for Koreans. ULs are defined as "the highest level of daily nutrient intake that is likely to pose no risk of adverse effects to almost all individuals in the general population." Koreans consume excess iodine from seaweed, and iodine intake is strongly influenced by seaweed consumption. However, no dose-response data derived from subjects consuming excess iodine frequently but not continuously during a lifetime are available. Therefore, the Korean DRI committee set the iodine UL to reduce the risk of adverse health effects by excess iodine intake for Koreans with distinctive seaweed-eating habits.

LC-MS/MS를 이용한 종자류 생약의 곰팡이독소 동시분석 및 위해도 평가 (Simultaneous Analysis of Mycotoxins and Risk Assessment in Seeds using LC-MS/MS)

  • 최은정;박영애;최수정;정삼주;박윤선;황인숙;유인실;신기영
    • 생약학회지
    • /
    • 제51권4호
    • /
    • pp.270-277
    • /
    • 2020
  • This study analyzed mycotoxins, aflatoxin B1, B2, G1, G2, fumonisin B1, B2, ochratoxin A and zearalenone, using LC-MS/MS and conducted risk assessment on 54 samples of seeds distributed in SeoulYangnyeongsi and the management status of extramural herbal dispensary facility. The matched calibration showed a good linearity as observed in 6 concentration levels(r2>0.999) as a result of method validation applied with Arecae semen. Limits of detection(LOD) and quantification(LOQ) were in the range of 0.02-0.11 ㎍/kg and 0.08-0.34 ㎍/kg, respectively. Recoveries also estimated, ranging from 65.1-99.7% with relative standard deviation(RSD) 0.5-6.3%. As a result of the method on 54 samples, mycotoxins were detected in 16 samples. Among them, two Thujae semen showed a degree of concentration that exceeded the aflatoxin specification. In the risk assessment, the human exposure safety standard values were calculated as ADI(Acceptable Daily Intake) for aflatoxin B1, fumonisin and zearalenone. Ochratoxin A was calculated as PTWI(Provisional Tolerable Weekly Intake). The MOE(Margine of Exposure) of aflatoxin B1 was in the range of 40.36-3536.88. And no items exceeded 100% in %TDI(Tolerable Daily Intake) and %TWI(Tolerable Weekly Intake) of fumonisin, zearalenone and ochratoxin A.

반 정량적 리스크 저감 요소를 고려한 철도 승강장 스크린 도어시스템의 안전 무결성 수준 할당 (Allocation of Safety Integrity Level for Railway Platform Screen Door System considering Semi-Quantitative Risk Reduction Factor)

  • 송기태;이성일
    • 한국안전학회지
    • /
    • 제31권4호
    • /
    • pp.156-163
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. However, the theoretical and practical study for safety integrity level is barely under way in the domestic railway industry. This research studied not only the global process of SIL allocation to guarantee safety in accordance with international standards for safety related equipment and system, but the quantitative methodology based on international standard and the semi-quantitative methodology as alternative way for SIL allocation. Specifically, the systematic SIL allocation for platform screen door system of railway is studied applying the semi-quantitative methodology in order to save much time and effort compared to quantitative method.

The Implementation of Risk-Based Inspection for the Refinery Plant

  • Choi, Song-Chun
    • Corrosion Science and Technology
    • /
    • 제11권2호
    • /
    • pp.43-47
    • /
    • 2012
  • Recently, regulatory bodies quite often encourage to adopt risk-based inspection (RBI) and management programs because they can enhance safety simultaneously with deregulation in Korea. RBI is an integrated methodology that factors risk into inspection and maintenance decision making. This paper describes an example of how to use known risk assessment codes (API 580, API 581 BRD) to address such safety analysis requirements for risk management in the refining industry. Specifically, this paper reports the methodology and the results of implementation to the Crude Distillation Unit(CDU) plant of refinery units using the $KGS-RBI^{TM}$ program, developed by the Korea Gas Safety Corporation in reference of API Codes and ASME PC (Post Construction) with a suitable consideration of Korean situation. The results of the risk and reliability assessment using $KGS-RBI^{TM}$ program are useful in determining whether the detected defects are tolerable or required to be repaired. The subsequent decisions are to manage the future inspection, repair and maintenance planning in the risk reduction control.

Establishment of the Korean Tolerable Daily Intake of Bisphenol A Based on Risk Assessments by an Expert Committee

  • Choi, Chan-Woong;Jeong, Ji-Yoon;Hwang, Myung-Sil;Jung, Ki-Kyung;Lee, Kwang-Ho;Lee, Hyo-Min
    • Toxicological Research
    • /
    • 제26권4호
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, reproductive and neurobehavioral effects of bisphenol A (BPA) have been documented, and thus a review was requested for BPA management direction by the government. Therefore, this study was performed to establish a Korean tolerable daily intake (TDI) for BPA. An expert committee, consisting of specialists in fields such as toxicology, medicine, pharmacology, and statistics, was asked to evaluate BPA health based guidance values (HbGVs). Although many toxicological studies were reviewed to select a point of departure (POD) for TDI, rat and mouse reproductive studies by Tyl et al. (2002, 2006), which were performed according to GLP standards and OECD guidelines, were selected. This POD was the lowest value determined from the most sensitive toxicological test. The POD, a NOAEL of 5 mg/kg bw/day, was selected based on its systemic toxicity as critical effects. An uncertainty factor of 100 including interspecies and intraspecies differences was applied to calculate the TDI. According to the evaluation results, a TDI of BPA for Korean was suggested at 0.05 mg/kg bw/day. In addition, the BPA exposure level based on food consumption by the Korean population was estimated as 1.509 ${\mu}g/kg$ bw/day, and the HI was evaluated at 0.03 when the TDI of 0.05 mg/kg bw/day was applied. This HI value of 0.03 indicated that hazardous effects would not be expected from BPA oral exposures. Although highly uncertain, further studies on low dose neurobehavioral effects of BPA should be performed. In addition, it is recommended that the 'as low as reasonably achievable' (ALARA) principle be applied for BPA exposure from food packaging materials in newborn infants and children.

높이 20미터 미만인 구조물의 낙뢰리스크 평가 (Lightning Risk Assessment for Structures Lower than 20m High)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.