• 제목/요약/키워드: titanium coated implant

검색결과 92건 처리시간 0.024초

질화 표면처리된 신장기를 이용한 수평적 치조골신장술 후 임플란트 식립시 골유착 효과에 관한 연구 (EFFECT ON THE OSTEOGENESIS OF DENTAL IMPLANTS AFTER HORIZONTAL DISTRACTION OSTEOGENESIS WITH NITRIFIED DISTRACTOR)

  • 박철민;김수관;김학균;문성용;오지수;백성문;임성철
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권3호
    • /
    • pp.225-231
    • /
    • 2008
  • This study evaluated whether there is a difference between a conventional titanium distraction device and a TiN-coated device in terms of implant osseointegration after horizontal distraction osteogenesis in narrow alveolar bone. Four adult mongrel dogs, each weighing $9{\sim}10kg$, were used in this study. The lower premolars were extracted and horizontal distraction was performed with conventional titanium distraction devices (group 1) or TiN-coated devices (group 2). After an 8-week consolidation period, the implants were installed, and the dogs were sacrificed after another 8 weeks. The osseointegration around the implants was evaluated histomorphologically. There was one failure in experimental group 1 because of fracture of the device. Direct bone contact was achieved and there were no significant differences between the control group and experimental groups 1 and 2 in terms of osseointegration around the implants at 8 weeks. In summary, intraoral distraction osteogenesis is a good option for augmenting severely atrophied alveolar ridges, and the TiN-coated device may be useful because of its advantages, which include surface hardness, corrosion resistance, and reduced bacteria.

Surface Observation of Mg-HA Coated Ti-6Al-4V Alloy by Plasma Electrolytic Oxidation

  • Yu, Ji-Min;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.198-198
    • /
    • 2016
  • An ideal orthopedic implant should provide an excellent bone-implant connection, less implant loosening and minimum adverse reactions. Commercial pure titanium (CP-Ti) and Ti alloys have been widely utilized for biomedical applications such as orthopedic and dental implants. However, being bioinert, the integration of such implant in bone was not in good condition to achieve improved osseointegraiton, there have been many efforts to modify the composition and topography of implant surface. These processes are generally classified as physical, chemical, and electrochemical methods. Plasma electrolytic oxidation (PEO) as an electrochemical route has been recently utilized to produce this kind of composite coatings. Mg ion plays a key role in bone metabolism, since it influences osteoblast and osteoclast activity. From previous studies, it has been found that Mg ions improve the bone formation on Ti alloys. PEO is a promising technology to produce porous and firmly adherent inorganic Mg containing $TiO_2$($Mg-TiO_2$ ) coatings on Ti surface, and the amount of Mg introduced into the coatings can be optimized by altering the electrolyte composition. In this study, a series of $Mg-TiO_2$ coatings are produced on Ti-6Al-4V ELI dental implant using PEO, with the substitution degree, respectively, at 0, 5, 10 and 20%. Based on the preliminary analysis of the coating structure, composition and morphology, a bone like apatite formation model is used to evaluate the in vitro biological responses at the bone-implant interface. The enhancement of the bone like apatite forming ability arises from $Mg-TiO_2$ surface, which has formed the reduction of the Mg ions. The promising results successfully demonstrate the immense potential of $Mg-TiO_2$ coatings in dental and biomaterials applications.

  • PDF

레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구 (TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY)

  • 안현정;김현철;최병갑;송언희;김래경
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

HA 코팅된 스테인레스강과 뼈의 계면에서의 경조직 성장 및 결합력 향상 (Bone Ingrowth and Enhancement of Bone Bonding Strength at Interface between Bone and HA Coated Stainless Steel)

  • 김철생;김상윤;김동헌;강곤
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.133-136
    • /
    • 1996
  • We investigated how hydroxyapatite (HA) coating onto a porous super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) affects bone ingrowth in a dog transcortical femoral model. Implants were histologically evaluated after 4 and 48 weeks of implantation, and the bone bonding strength at the bone/implant interface was examined by employing the pull-out test. The direct osseous tissue bonding onto the HA-coated S.S.S was observed, but the uncoated stainless steels had thin fibrous tissue layers. The mean interface strength of the HA-coated S.S.S was 1.5 and 2.5 times greater than those of the S.S.S and the 316L SS after one year of implantation, respectively. In preliminary studies, no toxic responce was observed from a cytotoxicity test of the S.S.S, having similar corrosion resistance to titanium. Our results suggest that early osteoconductive nature of HA coating may induce long term osteointegration for a bioinert substrate.

  • PDF

TiN/Ti 다층막 코팅된 생체용 Ti-30Ta-xZr 합금의 부식특성 (Corrosion Characteristics of TiN/Ti Multilayer Coated Ti-30Ta-xZr Alloy for Biomaterials)

  • 김영운;조주영;최한철
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.162-169
    • /
    • 2009
  • Pure titanium and its alloys are drastically used in implant materials due to their excellent mechanical properties, high corrosion resistance and good biocompatibility. However, the widely used Ti-6Al-4V is found to release toxic ions (Al and V) into the body, leading to undesirable long-term effects. Ti-6Al-4V has much higher elastic modulus than cortical bone. Therefore, titanium alloys with low elastic modulus have been developed as biomaterials to minimize stress shielding. For this reason, Ti-30Ta-xZr alloy systems have been studied in this study. The Ti-30Ta containing Zr(5, 10 and 15 wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24 hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and Ti coating and then coated with TiN, respectively, by using DC magnetron sputtering method. The analyses of coated surface were carried out by field emission scanning electron microscope(FE-SEM). The electrochemical characteristics were examined using potentiodynamic (- 1500 mV~+ 2000 mV) and AC impedance spectroscopy(100 kHz~10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The equiaxed structure was changed to needle-like structure with increasing Zr content. The surface defects and structures were covered with TiN/Ti coated layer. From the polarization behavior in 0.9% NaCl solution, The corrosion current density of Ti-30Ta-xZr alloys decreased as Zr content increased, whereas, the corrosion potential of Ti-30Ta-xZr alloys increased as Zr content increased. The corrosion resistance of TiN/Ti-coated Ti-30Ta-xZr alloys were higher than that of the TiN-coated Ti-30Ta-xZr alloys. From the AC impedance in 0.9% NaCl solution, polarization resistance($R_p$) value of TiN/Ti coated Ti-30Ta-xZr alloys showed higher than that of TiN-coated Ti-30Ta-xZr alloys.

다양한 양극산화막 처리방법이 임프란트 골유착에 미치는 영향 (EFFECT OF VARIOUS INODIZING CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANT SURFACE DESIGN)

  • 차수련;이준;민승기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.417-427
    • /
    • 2008
  • The aim of this study is to investigate the effect of anodizing surface to osseointegration of implant by using of resonance frequency analysis (RFA), quantitative and qualitative assessment of an anodically modified implant type with regard to osseous healing qualities. A total of 96 screw-shaped implants were prepared for this study. 72 implants were prepared by electrochemical oxidation with different ways. 24 (group 1 SP) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid. 24 (group 2GC) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate and 24 (group 3 CMP (Calcium Metaphosphate) Coating were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by CMP coating. Rest of 24 (control group were as a control group of RBM surface. Bone tissue responses were evaluated by resonance frequency analysis (RFA) that were undertaken at 2, 4 and 6 weeks after implant placement in the mandible of mini-pig. Group 1 SP (anodized with sulfuric acid and phosphoric acid implants) demonstrated slightly stronger bone responses than control Group RBM. Group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) demonstrated no difference which were compared with control group. Group 3 GMP (anodized and CMP coated implants) demonstrated slightly stronger and faster bone responses than any other implants. But, all observation result of RF A showed no significant differences between experimental groups with various surface type. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact for group 2 GC. Significantly more bone formation was found inside threaded area for group 2 GC. It was concluded that group 2 GC (anodized surface with calcium glycerophosphate and calcium acetate implants) showed more effects on the bone tissue responses than RBM surface in initial period of implantation. In addition, CMP showed a tendency to promote bone tissue responses.

성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향 (Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs)

  • 박찬경;김종은;신주희;류재준;허중보;신상완
    • 대한치과보철학회지
    • /
    • 제48권3호
    • /
    • pp.202-208
    • /
    • 2010
  • 연구 목적: 이 연구의 목적은 골형성단백질 (recombinant human Bone Morphogenetic Protein-2; rhBMP-2)이 코팅된 임플란트가 치조골 증대에 미치는 영향을 알아보는 것이다. 연구 재료 및 방법: 6마리의 비글견이 실험에 사용되었다. 6개의 8 mm 길이의 임플란트가 발치 후 6개월 이상의 충분한 치유기간이 경과한 비글견의 치조골에 5 mm 깊이로 식립되었다. 각각의 동물에 좌측과 우측의 악궁-분할형으로 임의추출하여 한쪽에는 1.5 ml/mg 농도의 rhBMP-2가 코팅된 임플란트를, 반대편에는 코팅되지 않은 대조군 임플란트를 식립하고 임플란트 주변 골에 round bur를 이용하여 피질골 천공을 시행하였다. 점막골막판막에 이완절개를 시행하여 판막을 접합시키고 봉합하여 임플란트가 피개되도록 하였다. 방사선 사진 촬영은 수술 직후 (기준치), 수술 4주후, 수술 8주 후에 시행하였다. 측정은 각 방사선 사진의 임플란트 덮개나사 최상방에서 변연골까지의 거리를 측정하여 골 형성량을 계산하였다. 수술 직후와 수술 8주 후에 임플란트 안정도 (Implant Stability Quotient value; ISQ value)를 측정하였다. 통계분석을 위해 SPSS software를 사용하여 Man-Whitney ranksum test와 Wilcoxon signed ranksum test를 시행하였다. 통계적 유의수준은P=.05를 기준으로 하였다. 결과: 골형성단백질이 코팅된 임플란트에서 수직 결손부 상방으로 약 0.6 mm의 골 형성이 관찰되었다. 대조군에서는 제한된 양의 골 형성 혹은 골 소실이 일어났다. 각 시기에 따른 실험군과 대조군간의 골 형성량에 유의한 차이가 있었다 (P<.05). ISQ value는 수술 직후에는 실험군과 대조군의 유의한 차이가 없었지만 수술 8주 후에는 실험군에서 대조군 보다 유의하게 높게 증가되었다 (P<.05). 결론: 골형성단백질이 코팅된 임플란트는 완전히 치유된 치조골에서 임상적으로 유의한 골 증대 효과가 있는 것으로 보인다.

표면처리가 다른 5종 임플랜트의 안정성에 관한 연구 (A STUDY ON THE STABILITY OF 5 DIFFERENT SURFACE TREATMENT METHODS TO DENIAL IMPLANT USING RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS)

  • 김선종;신상완;정성민;류재준
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.78-94
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the effects of various surface treatments by measuring resonance frequency and histomorphometric analyses. Material and methods. In 5 adult dogs, the mandibular premolar were extracted. Six months later, 30 screw titanium implants (Dentium Co., Seoul, Korea) 6mm in length and 3.4mm in diameter, were placed in the mandibles of 5 dogs. Implants were divided into five groups following to surface treatment methods ; Group 1 is machined controls, Group 2 is sandblasted with large grit and acid-etched (SLA), Group 3 is anodized (Autoelectric Co., Korea, 660Hz, Duty10), Group 4 is hydroxyapatite(HA) coated by ion beam assisted deposition(E-beam), Group 5 is hydroxyapatite(HA) coated with Sol-gel coating process. Resonance frequency was measured implant placement immediately, and 3, 6 weeks and 10 weeks of healing perods. With the animal subject's sacrifice 10 weeks after implantation, implants were removed on bloc and histologic and computer-based histomorphometric analyses were performed. Histomorphometric analysis involved quantification of the entire bone to metal contact around the implants. Statistical analyses were performed using the SPSS for Windows (ver. 9.0 SPSS Inc.) Statistical differences were considered significant at P<0.05. Results. The results were as follows : 1) In five groups, mean value of resonance frequency analysis(RFA) were highest in group 5 (Sol-gel implant) at implantation and those of group 4 (E-beam)was highest at 10 weeks . but there was no correlation between surface treatments and RFA. 2) In all surface treatment groups, the RFA values of implants decreased until 3 weeks and increased to 10 weeks. 3) The percentage of direct bone-to-implant contact (BIC) had statistical significance between five groups in cancellous bone, (P<0.05) the percentage of bone density inside the thread had no statistical significance between five groups. (P>0.05) 4) There was a significant difference between cortical bone and cancellous bone in BIC. (P<0.05) and bone density. (P<0.05) 5) There was a correlation between the RFA value of implants at 10 weeks and BIC in cancellous bone, and between the RFA value of implants at 10 weeks and bone density in cortical bone. (P<0.05). Conclusions. These results indicate that surface treatment does not affect the implant stability in case of good bone quality.

Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS)

  • 우진오;박봉욱;변준호;김승언;김규천;박봉수;김종렬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권1호
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Biocompatibility and Surface Characteristics of PEO-treated Ti-40Ta-xZr Alloys for Dental Implant Materials

  • Yu, Ji-Min;Cho, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.23-23
    • /
    • 2018
  • In this study, new titanium alloys were prepared by adding elements such as tantalum (Ta), zirconium (Zr) and the like to complement the biological, chemical and mechanical properties of titanium alloys. The Ti-40Ta-xZr ternary alloy was formed on the basis of Ti-40Ta alloy with the contents of Zr in the contents of 0, 3, 7 and 15 wt. %. Plasma electrolytic oxidation (PEO), which combines high-voltage sparks and electrochemical oxidation, is a novel method to form ceramic coatings on light metals such as Ti and its alloys. These oxide film produced by the electrochemical surface treatment is a thick and uniform porous form. It is also composed of hydroxyapatite and calcium phosphate-based phases, so it has the characteristics of bone inorganic, non-toxic and very high bioactivity and biocompatibility. Ti-40Ta-xZr alloys were homogenized in an Ar atmosphere at $1050^{\circ}C$ for 1 hour and then quenched in ice water. The electrochemical oxide film was applied by using a power supply of 280 V for 3 minutes in 0.15 M calcium acetate monohydrate ($Ca(CH_3COO)_2{\cdot}H_2O$) and 0.02 M calcium glycerophosphate ($C_3H_7CaO_6P$) electrolyte. A small amount of 0.0075M zinc acetate and magnesium acetate were added to the electrolyte to enhance the bioactivity. The mechanical properties of the coated surface of Ti-40Ta-xZr alloys were evaluated by Vickers hardness, roughness test, and elastic modulus using nano-indentation, and the surface wettability was evaluated by measuring the contact angle of the coated surface. In addition, cell activation and differentiation were examined by cell culture of HEK 293 (Human embryonic kidney 293) cell proliferation. Surface properties of the alloys were analyzed by scanning electron microscopy(FE-SEM), EDS, and X-ray diffraction analysis (XRD).

  • PDF