EFFECT ON THE OSTEOGENESIS OF DENTAL IMPLANTS AFTER HORIZONTAL DISTRACTION OSTEOGENESIS WITH NITRIFIED DISTRACTOR

질화 표면처리된 신장기를 이용한 수평적 치조골신장술 후 임플란트 식립시 골유착 효과에 관한 연구

  • Park, Chul-Min (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chosun University) ;
  • Kim, Su-Gwan (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chosun University) ;
  • Kim, Hak-Kyun (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chosun University) ;
  • Moon, Seong-Yong (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chosun University) ;
  • Oh, Ji-Su (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chosun University) ;
  • Baik, Sung-Mun (Department of Oral & Maxillofacial Surgery, School of Dentistry, Chosun University) ;
  • Lim, Sung-Chul (Department of Pathology, College of Medicine, Chosun University)
  • 박철민 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 김수관 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 김학균 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 문성용 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 오지수 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 백성문 (조선대학교 치과대학 구강악안면외과학교실) ;
  • 임성철 (조선대학교 의과대학 병리학교실)
  • Published : 2008.05.30

Abstract

This study evaluated whether there is a difference between a conventional titanium distraction device and a TiN-coated device in terms of implant osseointegration after horizontal distraction osteogenesis in narrow alveolar bone. Four adult mongrel dogs, each weighing $9{\sim}10kg$, were used in this study. The lower premolars were extracted and horizontal distraction was performed with conventional titanium distraction devices (group 1) or TiN-coated devices (group 2). After an 8-week consolidation period, the implants were installed, and the dogs were sacrificed after another 8 weeks. The osseointegration around the implants was evaluated histomorphologically. There was one failure in experimental group 1 because of fracture of the device. Direct bone contact was achieved and there were no significant differences between the control group and experimental groups 1 and 2 in terms of osseointegration around the implants at 8 weeks. In summary, intraoral distraction osteogenesis is a good option for augmenting severely atrophied alveolar ridges, and the TiN-coated device may be useful because of its advantages, which include surface hardness, corrosion resistance, and reduced bacteria.

Keywords

References

  1. Codivilla A : On the means of lengthening in the lower limbs, the muscles and tissues which are shortened through deformity. Clin Orthop Apr 301 : 4, 1994
  2. Ilizarov GA : Basic principles of transosseous compression and distraction osteogenesis. Orthop Tranumatol Protez 32 : 7, 1971
  3. Ilizarov GA : The principles of the Ilizarov method. Bull Hosp Jt Dis Orthop Inst 48 : 1, 1988
  4. Synder CC, Levine GA, Swanson HM et al : Mandibular lengthening by gradual distraction. Preliminary report. Plas Reconstr Surg 51 : 506, 1973 https://doi.org/10.1097/00006534-197305000-00003
  5. McCarthy JG, Schreiber J, Karp N et al : Lengthening the human mandible by gradual distraction. Plast Reconstr Surg 89 : 1, 1992 https://doi.org/10.1097/00006534-199289010-00001
  6. Block MS, Chang A, Crawford C : Mandibular alveolar ridge augmentation in the dog using distraction osteogenesis. J Oral Maxillofac Surg 54 : 309, 1996 https://doi.org/10.1016/S0278-2391(96)90750-8
  7. Chin M, Toth BA : Distraction osteogenesis in maxillofacial surgery using internal devices: Review of five cases. J Oral Maxillofac Surg 54 : 454, 1996 https://doi.org/10.1016/S0278-2391(96)90120-2
  8. Scarano A, Piattelli M, Vrespa G et al : Bacterial adhesion on titanium nitride-coated and uncoated implants: an in vivo human study. J Oral Implantol. 29 : 80, 2003 https://doi.org/10.1563/1548-1336(2003)029<0080:BAOTNA>2.3.CO;2
  9. Tetsu T, Katsuyuki F, Hironari S et al : Use of horizontal alveolar distraction osteogenesis for implant placement in a narrow alveolar ridge. A case report. Int J Oral Maxillofac Implants 19 : 291, 2004
  10. Fugazzotto PA : Report of 302 consecutive ridge augmentation procedures: Technical considerations and clinical results. Int J Oral Maxillofac Implants 13 : 358, 1998
  11. von Arx T, Cochran DL, Hermann JS et al : Lateral ridge augmentation and implant placement: An experimental study evaluating implant osseointegration in different augmentation materials in the canine mandible. Int J Oral Maxillofac Implants 16 : 343, 2001
  12. Ley J, Cranin AN : Distraction osteogenesis for augmenting the deficient alveolar ridge in preparation for dental implant placement: a case report. J Oral Implantol 30 : 14, 2004 https://doi.org/10.1563/1548-1336(2004)030<0014:DOFATD>2.0.CO;2
  13. Gaggl A, Schultes G, Karcher H : Vertical alveolar ridge distraction with prosthetic treatable distractions, Int J Oral Maxillofac Implant 15 : 701, 2000
  14. Davies J, Turner S, Sandy JR : Distraction osteogenesis-a review. Br Dent J 185 : 462, 1998 https://doi.org/10.1038/sj.bdj.4809838
  15. Swennen G, Schliephake H, Dempf R et al : Craniofacial distraction osteogenesis: a review of the literature. Part I: clinical studies. Int J Oral Maxillofac Surg 30 : 89, 2001 https://doi.org/10.1054/ijom.2000.0033
  16. Tomoo O, Hidebaru S, Masataka Y et al : Horizontal Alveolar Distraction of the narrow maxillary ridge for implant placement. J Oral Maxillofac Surg 62 : 1530, 2004 https://doi.org/10.1016/j.joms.2004.07.009
  17. Nosaka Y, Kitano S, Wada K et al : Endosseous implants in horizontal alveolar ridge distraction osteogenesis. Int J Oral Maxillofac Implants 17 : 846, 2002
  18. Goldberg JR, Gilbert JL : The electrochemical and mechanical behavior of passivated and TiN/AlN-coated CoCrMo and Ti6Al4V alloys. Biomaterials 25 : 851, 2004 https://doi.org/10.1016/S0142-9612(03)00606-9
  19. Goldberg JR, Gilbert JL : In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater 64 : 78, 2003
  20. Kim SG : Mastery of OSSTEM implant. Koonja Publishing Co., 2007
  21. Bolton J, Hu X : In vitro corrosion testing of PVD coatings applied to a surgical grade Co-Cr-Mo alloy. J Mater Sci Mater Med 13 : 567, 2002 https://doi.org/10.1023/A:1015126810485
  22. Dalmiglio M, Schaaff P, Holzwarth U et al : The effect of surface treatments on the fretting behavior of Ti-6Al-4V alloy. J Biomed Mater Res B Appl Biomater 2008 (in press)
  23. Tamura Y, Yokotama A, Watari F et al : Surface properties and biocompatibility of nitrided titanium for abrasion resistant implant materials. Dent Mater J 21 : 355, 2002 https://doi.org/10.4012/dmj.21.355
  24. Huang HH, Hsu CH, Pan SJ et al : Corrosion and cell adhesion behavior of TiN-coated and ion-nitrided titanium for dental applications. Appl. Surf. Science 244 : 252, 2005 https://doi.org/10.1016/j.apsusc.2004.10.144
  25. Groessner-Schreiber B, Neubert A, Mu¨ller WD et al : Fibroblast growth on surface-modified dental implants: an in vitro study. J Biomed Mater Res A 64 : 591, 2003