• Title/Summary/Keyword: time offset

Search Result 725, Processing Time 0.026 seconds

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Diagnosis on Degree of Saturation Model of COSMOS Affected by Geometric and Detection Conditions and Detector Placements (교통조건, 기하구조 조건 및 검지기 설치위치에 따른 실시간신호제어시스템 포화도 산출방식 진단)

  • KIM, Jun-Young;KIM, Jin Tae
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.1
    • /
    • pp.81-94
    • /
    • 2016
  • The Korean real-time traffic responsive control systems, Cycle Offset Split Model of Seoul (COSMOS), employs a single theoretical model to estimate the degree-of-saturation (DS) on approaches. However, the deployment of the system has been accomplished without practical consideration of its field performance. This paper delivers a diagnosis study performed to find the relationships yet known on the DS values against the operational conditions unproved in theory but ordinarily observed in field practice. Based on the analysis of the historical log data (476,505 cycles) obtained from the COSMOS server, it was found; (1) full coverage of lane detections should perform better than the sample coverage of detection in ordinary conditions, (2) the sample coverage of detection perform better than the other case with an exclusive bus lane, (3) detection in which a shared lane is involved provide poor estimation of DS, (4) poor DS estimation when a detection lane is adjacent to a shared lane, and (5) the DS values obtained during a day can hardly be stable all time. The findings suggest traffic engineers a progressive direction to move forward for the next real-time traffic control systems.

Microleakage and Shear Bond Strength of Biodentine at Different Setting Time (BiodentineTM의 경화시간에 따른 미세누출과 전단결합강도)

  • Song, Yong Ho;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.344-353
    • /
    • 2018
  • The purposes of this study were to evaluate microleakage of Biodentine, one of the tricalcium silicate based pulp-capping materials, and to compare the shear bond strength between composite resin and Biodentine with different setting times. For microleakage evaluation, 70 bovine teeth were used. Cavities were formed on the labial surfaces and filled with Biodentine. The teeth were divided into seven groups, each consisting of 10 teeth. The specimens were prepared by applying the composite resin on the upper side after different setting times. To evaluate shear bond strength, 210 acrylic resin blocks with central grooves were prepared, and the grooves were filled with Biodentine. The acrylic resin blocks were divided into seven groups of 30 specimens each, and the specimens were prepared by applying the composite resin on the upper side after different setting times. In samples with setting time of 24 hours or longer period, the microleakage between composite resin and Biodentine was reduced significantly while the shear bond strength increased to offset the polymerization shrinkage of the composite resin. Setting Biodentine for more than 24 hours before composite resin restoration would lead to more favorable clinical result.

DLL Design and Performance Evaluation in Indoor Wireless DS-CDMA System under the Multipath Fading Effects (실내 무선 DS-CDMA 방식에서 다중경로 페이딩 영향을 고려한 DLL 설계와 성능평가)

  • Im, Sung-Jun;Ryu, Ho-Jin;Ryu, Heung-Gyoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.99-105
    • /
    • 1997
  • This paper analyzes DLL(Delay lock loop) under the multipath fading effects. The evaluated performance measures include the steady-state timing error probability density function (PDF) and the mean-time-to-lose-lock (MTLL) under multipath fading effects. The discriminator characteristic S(${\epsilon}$) is shown to be zero at the point of timing error ${\epsilon}_{0}$ that is not zero, and the MTLL decreases as the delayed signal power $g_{2}$ and delayed time ${\tau}_{d}$ increase. We approximate the steady-state timing error PDF linearly with these variables and evaluate the steady-state timing error PDF and MTLL. The severe multipath fading effects result lower MTLL, in this case we make MTLL larger by increasing the early-late discriminator offset ${\Delta}$. First, we calculate the timing error point ${\epsilon}_{0}$, and present the performance of DLL under multipath fading. The timing error PDF, MTLL and the performance of DLL with ${\Delta}$ are also investigated. And we conclude that the larger ${\Delta}$ makes a higher MTLL and a better performance of DLL under multipath fading effects.

  • PDF

A Study on the Detection of Small Cavity Located in the Hard Rock by Crosswell Seismic Survey (경암 내 소규모 공동 탐지를 위한 시추공간 탄성파탐사 기법의 적용성 연구)

  • Ko, Kwang-Beom;Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.2
    • /
    • pp.57-63
    • /
    • 2003
  • For the dectection of small cavity in the hard rock, we investigated the feasibility of crosswell travel-time tomography and Kirchhoff migration technique. In travel-time tomography, first arrival anomaly caused by small cavity was investigated by numerical modeling based on the knowledge of actual field information. First arrival delay was very small (<0.125 msec) and detectable receiver offset range was limited to 4m with respect to $1\%$ normalized first arrival anomaly. As a consequence, it was turned out that carefully designed survey array with both sufficient narrow spatial spacing and temporal (<0.03125 msec) sampling were required for small cavity detection. Also, crosswell Kirchhoff migration technique was investigated with both numerical and real data. Stack section obtained by numerical data shows the good cavity image. In crosswell seismic data, various unwanted seismic events such as direct wave and various mode converted waves were alto recorded. To remove these noises und to enhance the diffraction signal, combination of median and bandpass filtering was applied and prestack and stacked migration images were created. From this, we viewed the crosswell migration technique as one of the adoptable method for small cavity detection.

Time-Varying Effects of Oil Shocks on the Korean Economy (한국경제에 미치는 유가충격의 시간-가변적 효과에 관한 연구)

  • Cha, Kyungsoo
    • Environmental and Resource Economics Review
    • /
    • v.27 no.3
    • /
    • pp.495-520
    • /
    • 2018
  • Because of structural changes in the international oil market and the economy, it is widely recognized that the impact of oil shocks on the economy has weaken since the mid-1980s. This study tries to examine the validity of the recent perception about the relationship between oils shocks and the economy, estimating the time-varying effects of oil shocks on the Korean economy. The results show that the dynamic effects of oil shocks normalized to a one standard deviation has been relatively constant, in contrast to the recent perception and a number of existing studies. In addition, because the shape of impulse response functions at each point in time spanning from 1984:II to 2017:IV has not been changed significantly, it seems that the propagation mechanism of oil shocks also has not been substantially altered. These findings indicate that even though structural changes of the economy, such as the reduction in the share of oil consumption and the spread of high-efficiency energy technologies, have been rapidly progressed, it is not still enough to offset the negative effects of oil shocks. Rather, it seems that the recent perception about the shrinking effects of oil shocks is mainly due to the assumptions that do not reflect changes in the size of oil shocks. In particular, this problem appears more pronounced in the case of the typical a one standard deviation increase oil shock under homoskedasticity assumption, which is widely adopted in the most VAR analyses. Therefore, in estimating the effects of oil shocks on the economy, it is important to specify the correct model and normalization method, to reflect changes in the size of oil shocks.

Design of a New CMOS Differential Amplifier Circuit (새로운 구조를 갖는 CMOS 자동증폭회로 설계)

  • 방준호;조성익;김동용;김형갑
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.6
    • /
    • pp.854-862
    • /
    • 1993
  • All of the CMOS analog and analog-digital systems have composed with several basic circuits, and among them, a important block, the amplifier part can affect the system's performance, Therefore, according to the uses in the system, the amplifier circuit have designed as various architectures (high-gain, low-noise, high-speed circuit, etc...). In this paper, we have proposed a new CMOS differential amplifier circuit. This circuit is differential to single ended input stage comprised of CMOS complementary gain circuits having internally biasing configurations. These architectures can be achieved the high gain and reduced the transistors for biasing. As a results of SPICE simulation with the standard $1.5{\mu}m$ processing parameter, the gain of the proposed circuit have a doubly value of the typical circuit's while maintaining other characteristics(phase margin, offset, etc...). And the proposed circuit is applicated in a simple CMOS comparator which has the settling time in 7nsec(CL=1pF) and the igh output swing $({\pm}4.5V)$.

  • PDF

Development of Programs to Analyze Mechanical Load Data of Wind Turbine Generator Systems and Case Studies on Simulation Data (풍력발전시스템의 기계적 하중 데이터 분석 프로그램 개발과 시뮬레이션 데이터 적용 사례)

  • Bang, Je-Sung;Han, Jeong-Woo;Gil, Kyehwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.789-798
    • /
    • 2013
  • The procedures and relevant programs developed for analyzing mechanical load data of wind turbine generator systems, which are obtained through type certification tests, are verified. The following issues according to IEC 61400-13 are covered in the developed programs: data validation, time series analysis, summary load statistics, generation of fatigue load spectra, and estimation of equivalent loads. A capture matrix for normal power production is generated to determine whether the collected data sets are sufficient to carry out fatigue analysis. Fatigue load spectra are obtained through the rainflow counting method using 50 load ranges; finally, equivalent loads are calculated using different S-N curve slopes, m, according to the relevant materials. Case studies are performed using aero-elastic simulation data of the NREL 5 MW baseline wind turbine with a monopile foundation.

Analysis of Kinetic Differences According to Ankle Taping Types in Drop Landing (드롭랜딩 시 발목테이핑 유형에 따른 운동역학적 차이 분석)

  • Lee, Kyung-Ill;Hong, Wan-Ki
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2014
  • The purpose of this study was to compare and analyze kinetic variables of lower limbs according to types of ankle taping in drop landing. For this, targeting seven male basketball players (average age: $20.8{\pm}0.74yrs$, average height: $187.4{\pm}3.92cm$, average weight: $79.8{\pm}7.62kg$) with no instability of ankle joints, the drop landing motion was conducted according to three types of inelastic taping (C-type), elastic taping (K-type), and no treatment (N-taping). Based on the result, the next conclusion was reached. First, the effect of taping for the players with stable ankles was minimal and the high load on ankle joints offset the fixing effect of inelastic taping. Thus the inelastic taping for the players with stable ankles did not have an effect on the control of dorsal flexion during one-foot landing. Second, increasing angular velocity by increasing the movable range of knee joints disperses impact forces, yet inelastic taping restricted the range of knee joint motion and at the same time increased angular velocity, adding to a negative effect on knee joints. Third, inelastic taping induced inefficient motion of Lower limbs and unstable impact force control of ankle joints at the moment of landing and produced maximum vertical ground reaction force, which led to an increase of load. Therefore, inelastic ankle taping of players whose jump actions occur very often should be reconsidered. Also, it is thought that this study has a great meaning in proving the problem of inelastic taping related to knee pain with unknown causes.

A Low Phase Noise Phase Locked Loop with Current Compensating Scheme (전류보상 기법을 이용한 낮은 위상 잡음 위상고정루프)

  • Song, Youn-Gui;Choi, Young-Shig;Ryu, Ji-Goo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.74-80
    • /
    • 2006
  • This work presents a novel architecture of phase locked loop (PLL) with the current compensating scheme to improve phase noise performance. The proposed PLL has two Charge Pump (CP), main-CP (MCP) and sub-CP (SCP). The smaller SCP current with same time duration but opposite direction of UP/DN MCP current is injected to the loop filter (LF). It suppress the voltage fluctuation of LF. In result, it improves phase noise characteristic. The Proposed PLL has been fabricated with 0.35fm 3.3V CMOS process. Measured phase noise at 1-MHz offset is -103dBc/Hz resulting in a minimum 3dBc/Hz phase noise improvement compared to the conventional PLL.