• Title/Summary/Keyword: tilted beam

Search Result 61, Processing Time 0.027 seconds

Laser Energy Optimization for Dissimilar Polymer Joining (이종폴리머 접합을 위한 레이저 에너지 최적제어 기법)

  • Song, Chi Hun;Choi, Hae Woon
    • Journal of Welding and Joining
    • /
    • v.32 no.2
    • /
    • pp.63-69
    • /
    • 2014
  • Dual laser heat sources were used for polymer based material joining. An infrared camera and thermocouple DAQ system were used to correlate the temperature distribution to computer simulation. A 50 degree tilted pre-heating laser source was acting as a heating source to promote the temperature to minimize thermal shock by the following a welding heat source. Based on the experimental result, the skin depth was empirically estimated for computer simulation. The offsets of 3mm, 5mm and 10mm split by weld and preheat were effectively used to control the temperature distribution for the optimal laser joining process. The closer offset resulted in an excessive melting or burning caused by sudden temperature rising. The laser power was split by 50%, 75% and 100% of the weld power, and the best results were found at 50% of preheating. To accurately simulate the physical laser beam absorption and joining optical properties were experimentally measured for the computer FEM simulation. The simulation results showed close correlation between theoretical and experimental results. The developed dual laser process is expected to increase productivity and minimize the cost for the final products.

A Satellite Tracking Method Using Rotation of Sub-Reflector for Naval Vessels Satellite Antenna System (부반사판 회전에 의한 함정용 위성 안테나의 위성 추적 방법)

  • Eom, Kwang-Sik;Park, Myung-Kwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.3
    • /
    • pp.39-44
    • /
    • 2007
  • In this paper, satellite searching and tracking method for the satellite antenna in naval vessels system are proposed. For fast searching satellite, Wide Range Search(WRS) algorithm is proposed where the signal strength of side-lobe is utilized as well as that of main-lobe. Satellite tracking algorithm to stabilize satellite antenna is based on conical-scanning which is accomplished by the use of the sub-reflector located in front of the focus of the reflector. The sub-reflector rotates about a slightly tilted axis by means of a motor and shapes the antenna beam to utilize stabilization. To show the validity of the proposed method, an experimental example is represented.

Fabrication of A 3-facet Mirror Using the LIGA Process (LIGA 공정을 이용한 삼면반사체 제작)

  • Oh, Dong-Young;Jung, Dong-Kwan;Park, Noh Y.;Chang, Suk-Sang;Lee, Seung-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.172-179
    • /
    • 2000
  • In this paper a technology for the fabrication of the oblique structure using the LIGA process will be presented. The fabricated microstructure is a tetrahedral 3- facet mirror. The mirror has an equilateral triangular base of hundreds ${\mu}m$ length mirror-like three side-facets inclined to the base at 45$^{\circ}$ and knife edges. Two regular triangles of 45$^{\circ}$ and tan-12. After development the shaded part of the PMMA the tetrahedral mirror remains, The completed mirror shows excellent aspects of mirror-like facets and knife-edges. By controlling the gap between the mask and the substrate the size of mirror easily can be changed. This mirror would be used as a laser beam splitter for the feedback control of the HDD slider.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

THE PRINCIPLE AND STRUCTURE OF THE GYUPYO (GNOMON) OF KING SEJONG'S REIGN TN CHOSON DYNASTY (조선의 세종시대 규표(圭表)의 원리와 구조)

  • Lee Yong-Sam;Jeong Jang-Hae;Kim Chun-Hwey;Kim Sang-Hyuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.289-302
    • /
    • 2006
  • For a reconstruct draft of the Gyupyo (Gnomon) in King Sejong Era, we collected a lot of documents of the Chosen Dynasty. With the result we made a reduced model by 1/10 and drawing set for the Gnomon in Sejong Era. It is composed of the Gyu, Yongpyo, Hoengryang (a beam), Yeongbu and granitic prop. You can read the scale where the shadow of vertically-standing stick touches the horizontal Gyu. A Shadow-Define. (Yeongbu) was used to focus the shadow cast by the sun's center, measuring the (gnomon) shadow length precisely. A Yeongbu is made of a leaf of copper in the middle of which is pierced a pin-hole for the tiny optical image of the sun which tilted to face the incident sunlight, used the principle of the a pin-hole camera and Scheimplug principle.

Phase Noise Filtering in Interferometer Using the Characteristic of SPPCM of $BaTiO_3$ ($BaTiO_3$의 SPPCM 특성을 이용한 간섭계의 위상 잡음 제거)

  • Han, Jeong-Yeop;Kim, Seong-Wan;Kim, Jong-Yun;Park, Se-Jun;Kim, Cheol-Su;Kim, Su-Jong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.122-127
    • /
    • 2001
  • The high stability of the interference pattern is very important in the case of measuring interference when a phase noise like a vibration occurs in the measuring environment. In this paper, we proposed the method of phase noise filtering by BaTiO$_3$ with the characteristic of SPPCM. Also, a beam with a shape of an ellipse was incident into BaTiO$_3$ by using the tilted lens so as to improve the reflectivity and the response time. And we confirmed the result by optical experiment.

  • PDF

EMC Measurements above 1 GHz Using an Offset Parabola Antenna System (옵셋 파라볼라 안테나를 이용한 1 GHz 이상에서의 전자파 적합성 평가)

  • Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1184-1193
    • /
    • 2010
  • The upper frequency of international EMC regulations is being expanded above 1 GHz. Radiated emissions above 1 GHz are different from those below 1 GHz that is existing upper regulation frequency, and which have lower field strength and sharper and tilted beam-width, relatively. In this paper, an effective evaluation method to be used above 1 GHz is studied using an offset parabola antenna system having a double-ridged horn antenna as a feed. First, simple model is proposed for calculating antenna factor and field uniformity of the parabola antenna system, and then real radiated emission and radiated susceptibility measurements are performed using a constant noise emitter and the suggested antenna system. The results show that the proposed antenna system has higher gain and power efficiency, and wider field uniformity relative to a conventional double-ridged horn antenna. Therefore, it is confirmed that the proposed system can be effectively used for EMC measurements above 1 GHz.

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF

A Study on Adjustable Base Station Antenna Based on Electrical Tilt for Null Steering (전기적 빔 조향기반의 기지국 안테나에 관한 연구)

  • Lee, Vea-O;Cheon, Chang-Yul;Chung, Young Seek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1128-1136
    • /
    • 2012
  • In this paper, we propose an electrically tilting system based on a null-steering in order to solve the problem of the shadowing loss caused by the mechanically tilted antenna system in mobile services. Especially, we improve the downward shadowing loss by eliminating or moving the vertical beampattern nulls between $-30^{\circ}{\sim}0^{\circ}$ to be able to tilt the downward beampattern between $-10^{\circ}{\sim}0^{\circ}$. The antenna has 14.5 dBi gain and side lobe level (SLL) is lower than -18 dB within downward tilting range. The isolation of polarization is greater than 30 dB when running in electric tilt down to $-10^{\circ}$. To verify this paper, we made the base-station antenna for W-CDMA and beam tilting devices, and verified the performances.

Effect of the Sag Height of a PDMS Microlens on the Acceptance Angle of an Artificial Compound Eye (겹눈 모사 구조체에서 마이크로 렌즈의 높이가 빛의 수용각에 미치는 영향 연구)

  • Jihyun, Jung;Mihee, Park;Hyerin, Song;Kyujung, Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.1
    • /
    • pp.13-21
    • /
    • 2023
  • We have investigated the acceptance angle and imaging performance of a curved artificial compound eye (ACE), depending on the sag height of the microlens array to maximize its sensitivity to light. When the h/r values increased from 0.22 to 0.37, the acceptance angle of the curved ACE was expanded from 28.70° to 49.02°, which is an enhancement by 70.8%. With the designed optical system, it was demonstrated that a microlens located at the 23rd position from the center of the main lens could still focus an incident beam tilted at 56.35°, so that the letter F was clearly observed.