• 제목/요약/키워드: tightening torque

검색결과 92건 처리시간 0.024초

소성역체결 볼트의 체결력과 마찰계수에 관한 연구 (Study on the Tightening Force and the Friction Coefficient in a Bolt tightened upto the Plastic Range)

  • 손승요;신근하
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.33-37
    • /
    • 1994
  • When a bolt is tightened up to the range of plastic deformation, yielding is governed by the combined stresses due to the axial force developed in the bolt and the frictional torque developed on the thread in contact with the nut. Consideration is taken account of the fact that the unused portion of the thread has least sectional area being subject to initial yielding. Once yielding has taken place some strain hardening effect will result, Incremental stress-strain relations are used to treat the continued yielding, which is equivalent to treat continued yielding as if summing up the effects of thin walled cylinders subject to plastic deformation. M10 bolts of common and fine series thread are used for computational purposes. Variation of axial forces and frictional torques vs. the frictional coefficients tare presented together with other plots showing some characteristics of bolt under plastic deformation.

  • PDF

체결 방식에 따른 유도탄의 동적 특성에 관한 실험적 연구 (Experimental Study on the Dynamic Characteristics of a Missile Structure Depending on Fastening Method)

  • 전호찬;송오섭
    • 한국군사과학기술학회지
    • /
    • 제22권4호
    • /
    • pp.452-459
    • /
    • 2019
  • In order to design and manufacture structures such as a guided missile, assembly process with fastener is an essential method of fabrication. In this study, the dynamic characteristics of a cylindrical structure with bolted joints were studied using experimental methods. The change of the natural frequency of the structure with the change of the fastening method and the tightening torque were measured by the test and the finite element analysis was performed using the stiffness model of the fastening part according to the fastening method and compared with the test results.

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향 (AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING)

  • 이태식;한중석;양재호;이재봉;김성훈
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.240-249
    • /
    • 2007
  • Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).

비계지지브라켓 유형별 구조기준 설정에 관한 실험적 연구 (Establishing the Structural Criteria to install Scaffolding-Use Brackets)

  • 손기상;갈원모
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.87-96
    • /
    • 1995
  • It is only three(3) years since we applied brackets for scaffolding in the construction area. Unfortunately, there is no structural criteria on how to install those in the site so far, despite the fact that those brackets have been applied into the site by the firms already. It is shown that resistant capacity of each bracket type has been investigated, analyzed from this experimental study. Accident-concerning data on construction site analyzed by the Ministry of Labor, show temporary structure involves 18.6% of the total industrial accident, which the accidents from scafold-supporting brackets have rate of 42.5% of the ones occurred from the temporary structures. There are two main aspects to be observed : one is how much resistant capacity the brackets have themselves, the other is how exactly to install those without eccentricity. But practically, nobody does check of this bolt-installing conditions in the site and no check of tightening level of nut because there is no available tool to check torque amount for this kind of nut. We just have to rely on scaffolders experience of this tightening. This experiment involves just this variable of tightness at site. Eventually this insufficient tightness causes to collapse those scaffolding structures. The bracket might have less the one than its original capacity due to this insufficient tightness. Three(3) times of PIVOT tests show that fractured condition of two(2) row brackets has occurred mostly at lower bolt due to shear force. Therefore, tightness of bracket-installing bolt, tensile strength of the bolt, shear strength of the bolt, loading condition with equal two point or inequal two point loads, are mainly investigated as variables in this study.

  • PDF

Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems

  • Jo, Jae-Young;Yang, Dong-Seok;Huh, Jung-Bo;Heo, Jae-Chan;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.491-497
    • /
    • 2014
  • PURPOSE. This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. MATERIALS AND METHODS. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. RESULTS. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). CONCLUSION. The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.

지대주 나사 풀림 방지를 위한 새로운 Lock Screw 시스템의 효과에 대한 유한요소해석적 연구 (Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening)

  • 임은섭;김종은;김지환;박영범
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.132-142
    • /
    • 2019
  • 목적: 본 유한요소해석적 연구는 새로운 Lock screw 시스템을 소개하고 그 역학적 특성을 분석하여 Lock screw가 지대주 나사 풀림을 방지할 수 있는지 알아보려고 한다. 연구 재료 및 방법: Lock screw는 임플란트 지대주 내부에 체결하여 지대주 나사 두부에 압축력을 가하는 장치이다. 그 효과를 알아보기 위해 CAD 프로그램을 이용하여 모델링을 하였고, 이를 다양한 하중조건 하에서 유한요소해석법을 이용해 분석하였다. 우선 지대주 나사의 조임회전력에 따른 전하중을 측정하고 이론 값과 비교하여 해석모델을 검증하였다. 검증된 해석 모델을 외부 하중이 없는 것과 178 N을 부여한 것으로 나누어 Lock screw의 조임회전력을 각각 10, 20, 30 Ncm으로 변화시켰고, 이때 임플란트 구성요소의 응력 분포가 어떠한 특성을 보이는지 살펴보았다. 결과: 여러 하중조건 하에서 Lock screw의 사용은 임플란트 구성요소의 항복강도를 넘어서는 등가응력을 발생시키지 않았다. 또한 지대주-지대주 나사 계면에서 축방향 하중의 증가를 보였다. 결론: Lock screw의 사용은 임플란트 구성요소에 과도한 응력을 가하지 않으며, 지대주-지대주 나사 계면의 마찰력을 증가시켜 지대주 나사 풀림을 방지할 수 있을 것으로 판단된다.

부스 바의 체결 및 중첩 구간에 따른 접촉 저항에 관한 연구 (A Study on the Contact Resistance according to the Tightening and Overlapping area of Bus Bar)

  • 김현우;손영득
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.56-62
    • /
    • 2018
  • 부스 바는 초고층 빌딩의 전력공급과 플랜트 산업의 전원 공급부 및 장비 제조 산업 분야의 배전반에 널리 사용되는 전기적인 접속 구조이다. 부스 바의 설계 시 고려해야 할 사항으로 사용 환경에 따른 재질, 전원 용량에 따른 단면적, 표면둘레의 길이, 체결 방법 등이 있다. 설계 시 충분한 전원 용량의 사이즈로 제작된 부스 바의 경우에도 실제 체결이 잘못 될 경우 열화에 의한 화재로 이어질 수 있다. 이러한 이유로 전기적 접촉부의 온도 상승에 대한 다양한 연구가 지속되어 왔다. 그러나 접촉부의 온도 상승은 결과에 기인한 현상이지 직접적인 원인은 아니다. 본 논문은 부스 바의 체결력과 중첩 구간에 따른 접촉 저항의 영향성에 대한 연구로 시편을 제작하여 저항의 변화를 측정하여 영향력을 분석하였다. 총 8개의 부스 바시편을 제작하여 측정하였고 각각의 시편을 교차하여 체결시 가해지는 체결력과 중첩 구간의 간격을 가변하여 저항을 측정하였다. 실험 결과를 통해 이러한 요인이 실제 접촉 저항의 변화에 어느 정도 기여하는지를 분석하여 안전한 전원 연결 장치의 모델을 제시하고자 한다.

임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태 (A study on accuracy and application of the implant torque controller used in dental clinic)

  • 주용훈;이진한
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.197-205
    • /
    • 2011
  • 연구 목적: 임상에서 사용하고 있는 임플란트 토크조절기의 정확도를 평가하고, 사용방법에 있어서 적절하게 적용하고 있는지의 사용실태를 조사하였다. 연구 대상 및 방법: 대전, 충청지역의 개인 치과 의원을 방문하여 50명의 임상의와 진료실에서 사용하고 있는 50개의 임플란트 토크조절기를 연구 대상으로 하였다. 실험에 참가한 임상의의 임플란트 시술에 대한 정보를 얻기 위해 설문조사를 시행하였다. 설문조사 내용에는 임상경력과 임플란트 시술 경력, 임플란트 시술 도중 경험한 임플란트 나사의 파절과 풀림, 임플란트 토크조절기 사용법에 대한 교육 이수 여부, 토크조절기의 감염 관리 방법을 포함하였다. 또한 실험을 통하여 진료실에서 사용하고 있는 토크조절기의 정확도를 평가하였다. 임상의가 토크조절기를 사용하여 측정된 토크 값을 측정 한 후, 임플란트 토크조절기에 대한 교육 이수에 따른 측정된 토크 값의 평균을 독립 변수 T 검정법을 시행하여 95% 신뢰수준에서 유의성을 검증하였다. 결과: 임상의가 사용하는 토크조절기 자체의 정확도를 측정한 결과, 50개 토크조절기의 평균 오차율은 4.78%였다. 평가된 50개 토크 조절기 중 최대 오차율은 18.96%, 최소 오차율은 0.88% 였다. 임상의가 의도한 25 Ncm의 토크 값에 대해 실제 측정된 토크 값 평균은 $29.0{\pm}8.4$ Ncm 이었고, 30 Ncm의 토크 값에 대해 실제 측정된 토크 값 평균은 $34.3{\pm}9.1$ Ncm였다. 각각의 실험에서 임플란트 토크조절기에 대한 교육을 받은 실험 군과 받지 않은 실험 군 간에 평균 값에서 통계적으로 유의한 차이를 나타냈다. 결론: 임상가는 자신이 의도한 토크 값과 실제 임플란트 나사에 가해지는 토크 값에 차이가 발생할 수 있으므로, 자신이 사용하는 토크조절기의 정확한 사용방법을 숙지하여 일정하고 정확한 토크 값을 부여해야 한다. 또한 토크조절기가 일정하고 정확한 토크 값을 유지하도록 토크조절기를 유지, 관리하여야 나사의 파절이나 나사의 풀림의 문제를 최소화하는 임상적인 결과를 얻을 수 있을 것으로 사료된다.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

일체형 지대주의 Diamond Like Carbon 표면 처리와 나사 조임 시기가 풀림 현상에 미치는 영향 (THE INFLUENCE OF ABUTMENT SCREW TIGHTENING TIMING AND DLC COATING OF CONICAL CONNECTION IMPLANT SYSTEM)

  • 김기홍;곽재영;허성주
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.209-216
    • /
    • 2008
  • 본 연구의 목적은 내측연결형 임플랜트와 일체형 지대주를 사용하여 최종 보철물을 시적한 뒤에 5만 번의 반복하중 후에 다시 체결하고 20만 번의 반복하중을 가한 후의 지대주 풀림토크와 20만 번의 반복하중을 받은 지대주 풀림토크가 어떻게 달라지는지를 비교하고자 하는 것이다. 실험 재료로는 타이타늄 지대주와 DLC 코팅된 지대주를 사용하였다. 실험군은 4군으로 모두 8개의 ITI SLA $4.1{\times}10mm$ 를 사용하였다. A군과 B군은 5만번, 20만번 반복하중을 가하고 Periotest값과 풀림 토크값을 측정하였으며 C군과 D군은 20만번 반복하중을 가하고 Periotest 값과 풀림토크값을 측정하였다. 풀림 토크값의 측정은 디지털 토크 게이지를 사용하였고, 반복하중은 MTS. (Bionix 850 II, MTS, U.S.A.)를 사용하였으며 100N/cm의 힘을 20도의 경사, 14Hz 의 조건으로 가하였다. A군과 C군은 코팅하지 않은 타이타늄 지대주를 사용하였으며, B군과 D군은 DLC 코팅한 지대주를 사용하였다. 1. 5만번 반복하중을 가한 뒤 측정한 풀림 토크는 B군에서 약간 더 큰 평균값을 보였다. 하지만 통계학적으로 두 군간에 유의한 차이를 보이지 않았다 (P>0.05). 2. 20만번 반복하중을 가한 뒤 측정한 최종 풀림 토크 값은 A군은 C군보다, B군은 D군보다 약간 더 큰 평균값을 보였으나 통계학적으로 두 군간에 유의한 차이를 보이지 않았다 (P>0.05). 3. 20만번 반복하중을 가한 최종 풀림 토크 값은 A, B군과 C, D군 사이에 통계학적으로 유의할 만한 차이가 없었다 (P>0.05).