AN INFLUENCE OF ABUTMENT MATERIALS ON A SCREW-LOOSENING AFTER CYCLIC LOADING

임플랜트 상부구조의 재료가 반복하중 후 나사풀림에 미치는 영향

  • Lee, Tae-Sik (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Han, Jung-Suk (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Yang, Jae-Ho (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Lee, Jae-Bong (Department of Prosthodontics, School of Dentistry, Seoul National University) ;
  • Kim, Sung-Hun (Department of Prosthodontics, School of Dentistry, Seoul National University)
  • 이태식 (서울대학교 치과대학 치과보철학교실) ;
  • 한중석 (서울대학교 치과대학 치과보철학교실) ;
  • 양재호 (서울대학교 치과대학 치과보철학교실) ;
  • 이재봉 (서울대학교 치과대학 치과보철학교실) ;
  • 김성훈 (서울대학교 치과대학 치과보철학교실)
  • Published : 2007.04.30

Abstract

Statement of problem: A phenomenon of screw-loosening in implant abutment is frequently occurred in a single and multiple implant restoration. Purpose: This study was performed to evaluate an effect of abutment material on screw-loosening before and after a cyclic loading. In a single-tooth implant, different materials of abutment, Type III Gold alloy and Zirconium composite$(ZrO_2/Al_2O_3)$ were used. Material and method: The Gold alloy(Type III) and Zirconium composite$(ZrO_2/Al_2O_3)$ were used to make a superstructure of implant, the one of types of UCLA, Each group was constituted of 5 sample with a 30-degree offset angulated loading platform. The external hexagonal fixture was rigidly hel d in a special holding zig to ensure solid fixation without rotation during the tightening and a cyclic loading. A Titanium-alloy screw was used to connect and controlled to be tighten in 20Ncm torque by a digital torque gauge. A 20 times of consecutive closing/opening cycle were performed to evaluate the immediate torque loss. In 5 sample of each material group, an initial opening torque was recorded during 3 closing/opening cycle, then 2Hz, 200N, 1,000,000 cyclic loadings were performed, then a opening torque was evaluated. Result & Conclusion: 1. In this limited study, titanium alloy screw tightened in 20Ncm, a cold-welding phenomen on was not observed during the 20 times of closing/opening cycle(p=0.11, p=0.18). 2. In titanium alloy abutment screw, repeated opening and closing of the screw caused to progressive decrease of opening torque(p=0.014). 3. The difference in preload of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant(p=0.78). 4. The difference in torque loss of screw between gold alloy abutment and ceramic$(ZrO_2/Al_2O_3)$ abutment was not significant after 2Hz,200N, 1,000,000 cyclic loading(p=0.92). 5. In titanium alloy abutment screw tightened by 20Ncm, the screw loosening was not significant on each group after 2Hz, 200Ncm, 1,000,000 cyclic loading(p=0.59).

Keywords

References

  1. Branemark PI. Osseointegration and its experimental back ground. J Prosthet Dent 1983;50:397
  2. Bo Rangert, Mech Eng, Lars Jorneus, Torsten Jemt. Forces and moments on Branemark Implants. Int J Oral Maxillofac Implants 1989;4:241-247
  3. Jorneus L, Jemt T. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9
  4. Kallus T, Blessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5years. Int J Oral Maxillofac implants 1994;9:168-178
  5. Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirementsfor fixed prostheses and overdentures in edentulous mandible : a 5-year report.Int J Oral Maxillofac implants 1994;9:191-196
  6. Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants : the Toronto Study. PartIII : problems and complications encountered. J Prosthet Dent 1990;64:185-194 https://doi.org/10.1016/0022-3913(90)90177-E
  7. Jemt T. Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report. Clin Oral Implants Res 1994;5:142-147 https://doi.org/10.1034/j.1600-0501.1994.050304.x
  8. Jemt T, Lekholm U. Implant treatment in edentulous maxillae:a 5-year follow-up report on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implants 1995;10:303-311
  9. Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH, Polizzi G. Osseointegrated implants for single tooth replacement : A 1-year report from a multicenter prospective study. Int J Oral Maxillofac 1991;6:29
  10. Quirynen NI, van Steenberghe D, Darius P. A six year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-245 https://doi.org/10.1016/0022-3913(92)90461-I
  11. Edwin A. McGlumphy, Deborah A. Mendel, Julie A. Holloway. Implant screw mechanics. Dental Clinics of North America 1998;42:71-89
  12. Griffith HT. Suggested tightening torques for structural bolts. Fastener Technology/ Feb 1987:p78-85
  13. Trilling J. Torque data for socket-head cap screws. Fastener Technology 1988; Feb:3-4
  14. Bickford JH. An introduction to the design and behavior of bolted joints. New York :Marcel Dekker. Inc. 1981
  15. Hubertus Spiekermann, Murat Yildirim. Ceramic abutment-a new era in achieving optimal esthetics in implant dentistry. Int J Periodontics Restorative Dent 2000; 20:81-91
  16. C Piconi, G Maccauro. Zirconia as a ceramic biomaterial. Biomaterials 1999:20:1-25 https://doi.org/10.1016/S0142-9612(98)00010-6
  17. Guido Heydecke. Evolution and use of aluminum oxide single-tooth implant abutment : A short review and presentation of two cases. Int J Prosthodont 2002; 15;488-493
  18. Bernt Andersson. Alumina Ceramic Implant abutments used for single-tooth replacement: A prospective 1- to 3-year Multicenter study. Int J Prosthodont 2001; 14;432-438
  19. Cho HW. A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns. Int J Prosthodont 2002;15:9- 13
  20. Bert Andersson. Mechanical testing of superstructures on the CeraOne abutment in the Branemark system. Int J Oral Maxillofac Implants 1994;9:665- 672
  21. Yildrum M, Fischer H. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent 2003; 90(4):325-331 https://doi.org/10.1016/S0022-3913(03)00514-6
  22. Kim DJ, Lee MH, Lee DY, Han JS. Mechanical properties, phasestability, and biocompatibility of(Y,Nb)-TZ P/Al(2)O(3) composite abutments for dental implant. J Biomed Mater Res 2000; 53(4):438-443 https://doi.org/10.1002/1097-4636(2000)53:4<438::AID-JBM19>3.0.CO;2-3
  23. Craig RG, Powers JM. Restorative dental materials. 11th ed. St. Louis: Mosby;2002: p.68-69
  24. Richter EJ. In vivo vertical forces on implants. Int J Oral Maxillofac Implants 1995;10:99-108
  25. Graf H. Bruxism. Dent Clin North Am 1969;13:659-65
  26. Gibb CH, Mahan PE, Mauderli A, Lundeen HC, Walsh EK. Limits of human bite strength. J Prosthet Dent 1986:56:226-229 https://doi.org/10.1016/0022-3913(86)90480-4
  27. Fontijn-Tekamp FA, Slagter AP, van t Hof MA. Bite forces with mandibular implantretained overdenture. J Dent Res 1998; 77:1832-1839 https://doi.org/10.1177/00220345980770101101
  28. Lee JS. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device. J Prosthet dent 2002; 88:402-408 https://doi.org/10.1067/mpr.2002.128099
  29. Sutter F, Weber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Periodont Rest Dent 1993;13:409-431
  30. Michal R. Norton, Assessment of cold welding properities of the internal conical interface of the commercially available implant systems. J Prosthet Dent 1999; 81:2:159-66 https://doi.org/10.1016/S0022-3913(99)70243-X
  31. Ervin I. Weiss, Dan Kozak, Martin D. Gross, Effect of repeated closures on opening torque values in seven abutment- implant systems. J Prosthet Dent 2000;84:2:194-199 https://doi.org/10.1067/mpr.2000.108069
  32. Tom. W. P. Korioth, Antonio C. Cardoso. Effect of washers on reverse torque displacement of dental implant gold retaining screws. J Prosthet Dent 1999;82: 312-316 https://doi.org/10.1016/S0022-3913(99)70086-7
  33. Mcglumphy E. Keeping implant screws tight. J Prosthet Dent 1994;72:628
  34. Adrian ED, Karantz WA, Ivanhoe J. Turna KA. A silicone obturator for the access canal in an implant-retained fixed prosthesis. J Prosthet Dent 1991:69:597
  35. Scherrer SS, Kelly JR, Quinn GD, Xu K. Fracture toughness(KIc)of a dental porcelain determined by fractographic analysis. Dent Mater 1999;15;342-348 https://doi.org/10.1016/S0109-5641(99)00055-X
  36. McCabe JF. Ceramic and Metal-Bonded Ceramics. Applied Dental Materials, ed 7. Oxford: Blackwell,1990:71-77