• 제목/요약/키워드: three dimensional conformal radiotherapy

검색결과 71건 처리시간 0.031초

Gemcitabine-based Concurrent Chemoradiotherapy Versus Chemotherapy Alone in Patients with Locally Advanced Pancreatic Cancer

  • Wang, Bu-Hai;Cao, Wen-Miao;Yu, Jie;Wang, Xiao-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.2129-2132
    • /
    • 2012
  • Objective: To explore improved treatment by retrospectively comparing survival time of gemcitabine-based concurrent chemoradiotherapy (GemRT) versus chemotherapy (Gem) alone in patients with locally advanced pancreatic cancer (LAPC). Methods: From January 2005 to June 2010, 56 patients with LAPC from Subei People's Hospital were treated either with Gem (n=21) or GemRT (n=35). Gem consisted of 4-6 cycles gemcitabine alone (1000 mg/m2 on Days 1, 8, 15, 28-day a cycle). GemRT consisted of 50.4Gy/28F radiotherapy with concurrent 2 cycles of gemcitabine (1000 $mg/m^2$ on days of radiation 1, 8, 15, 21-day a cycle). Radiation was delivered to the gross tumor volume plus 1-1.5 cm by use of a three-dimensional conformal technique. The follow-up time was calculated from the time of diagnosis to the date of death or last contact. Kaplan-Meier methodology wes used to evaluate survival. Results: Patient characteristics were not significantly different between treatment groups. The disease control rate and the objective response rate of GemRT versus Gem was 97.1% vs 71.4%, 74.3% vs 38.1%. The overall survival (OS) was significantly better for GemRT compared to Gem (median 13 months versus 8 months; 51.4% versus 14.3% at 1 year, respectively). Conclusion: Radiation therapy at 50.4Gy with 2 concurrent cycles of gemcitabine results in favorable rates of OS. Concurrent chemoradiotherapy should be the first choice for patients with LAPC.

뇌.두경부 방사선치료 시 전자조사문영상장치를 이용한 세트업 오차 확인에서 제2경추 치상돌기 위치의 임상적 의의 (Location Error of the Dens in a Two-Dimensional Set-up Verification During Head and Neck Radiotherapy)

  • 김동현;김원택;기용간;남지호;이미란;전호상;박달;김동원
    • Radiation Oncology Journal
    • /
    • 제29권2호
    • /
    • pp.107-114
    • /
    • 2011
  • 목 적: 뇌 두경부 종양의 방사선치료에서 전자조사문영상장치(electronic portal imaging device)를 이용한 조사문 영상에서 제2경추 치상돌기(dens)의 좌우 위치변화를 측정하고 이것이 치료에 미치는 임상적 의의에 대해 알아보고자 하였다. 대상 및 방법: 2009년 1월 1일부터 2010년 6월 30일까지 뇌 두경부 종양으로 해당 부위에 3차원 입체조형방사선치료 또는 세기조절방사선치료를 받았던 21명의 환자를 대상으로 하였다. 모의치료 시 획득한 디지털재구성사진과 방사선치료 기간 중 정기적으로 촬영한 전면 조사문영상에서 코중격과 치상돌기의 X축 방향에서 위치오차를 측정하였다. 또한 방사선치료 계획용 프로그램을 이용하여 위치오차가 발생하였을 때, 주변 정상 장기 및 치료 표적의 선량 분포에 미치는 영향을 알아보았다. 결 과: 총 확인한 조사문영상은 400개였다. 평균 위치오차는 절대값으로 측정하였을 때 코중격에서 0.16 mm, 치상돌기에서 0.33 mm였다. 3 mm 이상 오차를 보인 경우가 코중격에서는 43번(10.7%), 치상돌기에서는 133번(33.1%)이었고, 5 mm 이상 오차를 보인 경우는 코중격에서는 없었으나 치상돌기에서는 11번(2.7%) 확인 되었다. 5 mm 이상 dens의 위치오자가 발생한 경우를 방사선치료 계획용 프로그램을 이용하여 재현해 보았을 때, 임상표 적체적의 선량조사 감소(V95: 100%${\rightarrow}$87.2%), 척수의 과도한 선량 조사가 이루어지는 것으로 나타났다(V45: <0.1%${\rightarrow}$12.6%). 결 론: 뇌 두경부의 방사선조사 시에 전자조사문영상장치를 이용하여 일부 환자들에서 치상돌기 오차를 비교적 쉽게 발견할 수 있는데, 코(얼굴의 앞면) 부분이 잘 맞더라도 5 mm 이상의 치상돌기 위치 오차가 발생할 수 있으므로 주의가 필요하겠다.

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.

근치적 절제술 후 병기3의 비소세포성 폐암에서 수술 후 방사선 치료의 역할 (Role of Postoperative Radiotherapy for Patients with Pathological Stage III Non-Small-Cell Lung Cancer after Curative Resection)

  • 김미영;우홍균;김학재;허대석;김영환;김동완;이세훈;김주현;김영태;강창현
    • Radiation Oncology Journal
    • /
    • 제29권1호
    • /
    • pp.44-52
    • /
    • 2011
  • 목적: 본 연구는 근치적 절제술 후 병기 3의 비소세포성 폐암에서 방사선 치료의 결과와 이에 영향을 주는 예후 인자를 분석해 보고자 하였다. 대상 및 방법: 2000년부터 2007년까지 88명의 환자가 비소세포성 폐암으로 근치적 절제술 후 병기 3기로 진단받았고, 수술 후 방사선 치료를 시행 받았다 이중 80명의 환자가 병기 3A였으며, 8명의 환자가 병기 3B였다. 83명의 환자는 림프절 병기 N2였으며 이들 중 56명은 단일 부위(single-station)의 종격동 림프절 전이였다. 76명은 2차원, 12명은 3차원 입체조형치료로 수술 후 망사선 치료를 받았다. 총 선량은 30.6에서 63 Gy 였으며 중앙값은 54 Gy였다. 36명의 환자가 항암치료를 시행받았다. 결 과: 생존기간은 26~77개월이었다(중앙값, 54개월). 5년 생존율 및 무병생존율은 각각 45%, 38%였다. 전이된 림프절개수가 생존율에 영향을 미치는 인자로 분석되었다(hazard ratio, 1.037; p=0.040). 5년 국소제어율 및 원격 전이제어율은 각각 88%, 48%였다. 종격동 림프절 부위의 전이가 단일 부위(single-station)인 경우가 무병생존율(p=0.0014)과 원격전이제어율(p=0.0044)을 의미 있게 증가시켰다. 총 51명의 재발이 발생하였으며 국소구역 재발은 10명, 원격전이는 41명이었다. 10명의 국소구역 재발 중에 6명은 방사선 치료 범위 내에서 재발하였다. Radiation Therapy Oncology Group(RTOG) 2도의 방사선 폐렴은 3명의 환자에서 보였으며 증상은 진해성 약제만으로도 조절이 잘 되었다. CTCAE 2도의 방사선 식도염은 11명의 환자에서 관찰되었다. 수술 후 방사선 치료로 인한 3도 이상의 심각한 부작용은 관찰되지 않았다. 결 론: 본 연구에서 국소 진행 비소세포성 폐암에서 근치적 수술 후 방사선 치료는 안전하고 임상적으로 적용 가능한 치료법이며, 국소제어를 증가시킬 수 있는 것으로 분석되었다. 예후인자로는 전이된 림프절 개수와 종격동 림프절 부위가 생존율에 영향을 미치는 것으로 분석되었다. 또한 국소 진행 비소세포성 폐암의 대부분의 재발 형태인 원격 전이를 감소시키기 위한 추가적인 노력이 필요할 것으로 생각된다.

비인두암의 방사선치료 시 삼차원입체조형 치료기법과 용적세기조절회전치료기법의 비교연구 (A Comparative Study of Radiation Therapy Planning between Volumetric-Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Nasopharyngeal Cancer)

  • 김지성;이석호;이승헌;김혜영;최진호;이규찬;김동영
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.171-177
    • /
    • 2010
  • 연구목적 : 비인두암 환자들을 대상으로 방사선치료 시 삼차원입체조형치료기법과 용적세기조절회전치료기법을 비교하고 이하선을 포함한 정상조직 보호에 있어 그 차이점을 알아 보고자 본 연구를 시행하였다. 대상 및 방법 : 비인두암 환자 5명을 대상으로 치료계획용 CT(computed tomography)를 시행 후 삼차원입체조형방사선치료계획 과 용적세기조절회전치료계획을 시행하였다. 이를 바탕으로 얻은 선량분포, conformity index(CI) 그리고 선량체적 히스토그램을 통해 손상위험장기(organ at risk)와 계획용표적체적(planning target volume)을 비교 분석하였다. 결 과 : 분석결과 이하선에 조사되는 평균선량이 용적세기조절회전치료계획에서는 43.9%로 삼차원입체조형치료계획에서의 89.4% 보다 유의하게(p=0.043) 감소하였다. 계획용표적체적 conformity index의 경우 용적세기조절회전치료계획 (CI=1.06)에서 삼차원입체조형치료계획(CI=2.55) 보다 유의하게(p=0.043) 향상된 결과를 보였다. 결 론 : 비인두암 환자에서 용적세기조절회전 치료계획 시 삼차원입체조형치료계획 보다 유의하게 이하선에 평균선량이 줄었고 계획용 표적체적에 대한 conformity도 유의하게 향상되는 결과를 보였다. 본 연구가 적은 수의 환자를 대상으로 하였으나 용적세기조절회전치료기법을 시행 시 구강건조증의 발생을 줄일 수 있을 것으로 기대된다. 향후 더 많은 환자군을 대상으로 한 임상연구가 필요할 것으로 사료된다.

Patterns of recurrence after radiation therapy for high-risk neuroblastoma

  • Jo, Ji Hwan;Ahn, Seung Do;Koh, Minji;Kim, Jong Hoon;Lee, Sang-wook;Song, Si Yeol;Yoon, Sang Min;Kim, Young Seok;Kim, Su Ssan;Park, Jin-hong;Jung, Jinhong;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • 제37권3호
    • /
    • pp.224-231
    • /
    • 2019
  • Purpose: To investigate the patterns of recurrence in patients with neuroblastoma treated with radiation therapy to the primary tumor site. Materials and Methods: We retrospectively analyzed patients with high-risk neuroblastoma managed with definitive treatment with radiation therapy to the primary tumor site between January 2003 and June 2017. These patients underwent three-dimensional conformal radiation therapy or intensity-modulated radiation therapy. A total of 14-36 Gy was delivered to the planning target volume, which included the primary tumor bed and the selected metastatic site. The disease stage was determined according to the International Neuroblastoma Staging System (INSS). We evaluated the recurrence pattern (i.e., local or systemic), progression-free survival, and overall survival. Results: A total of 40 patients with high-risk neuroblastoma were included in this study. The median patient age was 4 years (range, 1 to 11 years). Thirty patients (75%) had INSS stage 4 neuroblastoma. At the median follow-up of 58 months, there were 6 cases of local recurrence and 10 cases of systemic recurrence. Among the 6 local failure cases, 4 relapsed adjacent to the radiation field. The other 2 relapsed in the radiation field (i.e., para-aortic and retroperitoneal areas). The main sites of distant metastasis were the bone, lymph nodes, and bone marrow. The 5-year progression-free survival was 70.9% and the 5-year overall survival was 74.3%. Conclusion: Radiation therapy directed at the primary tumor site provides good local control. It seems to be adequate for disease control in patients with high-risk neuroblastoma after chemotherapy and surgical resection.

감각신경모세포종의 20년에 걸친 치료와 예후 분석: 치료 시기에 따른 차이 (Treatment and Prognosis for an Esthesioneuroblastoma over a 20-Year Period: Impact of Treatment Era)

  • 송창훈;김일한;우홍균;김동완;이재서
    • Radiation Oncology Journal
    • /
    • 제27권4호
    • /
    • pp.189-193
    • /
    • 2009
  • 목 적: 감각신경모세포종의 시대에 따른 치료방침과 생존율의 변화를 보고하고자 하였다. 대상 및 방법: 1989년 3월부터 2007년 6월 사이에 감각신경모세포종으로 진단을 받고 처음으로 치료를 받은 42명의 환자를 후향적으로 분석하였다. Kadish 병기에 따르면, 3명(7%)의 환자가 A병기, 6명(14%)의 환자가 B병기, 33명(79%)의 환자가 C병기였다. 33명의 C병기 환자 중, 19명은 1989년부터 2000년에, 14명은 2001년부터 2007년까지 치료 받았다. 치료는 수술, 방사선치료, 항앙화학요법 및 이들의 조합이었다. 1989년부터 2000년까지 치료를 받은 19명 중 8명(42%)이 항암화학요법을 받은 것에 비해, 2001년부터 2007년까지 치료를 받은 환자 14명은 모두 항암화학요법을 받았다(p<0.001). 삼차원입체조형방사선치료는 1989년부터 2000년에는 아무도 받지 않았으나 2001년부터 2007년도에 치료를 받은 14명 중 8명이 받았다(p<0.001). 생존환자에 대한 중앙 추적기간은 6.5년(범위, 2.2~15.8년)이었다. 결 과: 전체 환자에 대한 5년 생존율과 무진행생존율은 각각 53%와 39%였다. Kadish A혹은 B 환자의 5년 생존율은 100%이고 Kadish C병기의 5년 생존율은 39%였다(p=0.007). C병기 환자 중 1989년부터 2000년까지 치료받은 환자와 2001년부터 2007년까지 치료받은 환자의 5년 생존율은 각각 26%와 59%였다(p=0.029). 상응하는 5년 무진행생존율은 각각 16%와 46%였다(p=0.001). 다변량분석에서 안와내침범과 치료시대(1989~2000 vs. 2001~2007)가 생존율과 무진행생존율에 영향을 주는 독립인자로 확인되었다. 결 론: 본 연구의 결과 C병기 환자에서 삼차원입체조형방사선치료의 도입과 같은 치료방법과 기술의 진화를 반영하는 치료시기가 향상된 생존율과 무진행생존율의 원인이 될 수도 있음을 제시 하였다. C병기 환자에서 더 나은 결과를 얻기 위해서는 수술에 더하여 항암화학요법과 방사선치료 병용요법, 특히 삼차원입체조형방사선치료가 추천된다.

전립선암의 방사선치료시 방광 부피가 비뇨기계 부작용에 미치는 영향 (The Impact of Bladder Volume on Acute Urinary Toxicity during Radiation Therapy for Prostate Cancer)

  • 이지혜;서현숙;이경자;이레나
    • Radiation Oncology Journal
    • /
    • 제26권4호
    • /
    • pp.237-246
    • /
    • 2008
  • 목 적: 국소적 전립선암에 대한 근치적 목적의 방사선치료시 3차원 입체조형방사선치료(3-dimensional conformal radiotherapy, 3DCRT) 또는 세기조절방사선치료(intensity modulated radiotherapy, IMRT)를 시행하면 직장의 부작용이 현저히 감소하지만 비뇨기계 부작용의 발생률은 감소하지 않는다. 방사선 치료로 인한 급성 비뇨기계 부작용은 환자의 삶의 질을 저하시킬 뿐 아니라 만성 비뇨기계 부작용의 발생을 증가시킨다. 따라서 비뇨기계 부작용을 줄이기 위해 방광을 채운 상태에서 방사선치료를 하는 방법이 제안되었는데 이 경우 방사선 조사야에 포함되는 방광의 면적이 줄어들어 부작용이 감소한다고 알려져 있다. 본 연구에서는 전립선암의 방사선치료시 방광의 부피가 급성 비뇨기계 부작용에 미치는 영향에 대하여 알아보고자 한다. 대상 및 방법: 전립선암으로 근치적 목적의 방사선치료를 받은 환자 42명을 대상으로 하였으며 대조군과 실험군이 각각 21명씩 포함되었다. 대조군은 본 연구가 계획되기 전에 방광 조절을 하지 않고 방사선치료를 시행 받은 환자 중 무작위로 추출하였고, 실험군은 치료 1시간 전 450 ml의 물을 마셔 방광을 채운 상태에서 방사선치료를 받은 환자들이었다. 모의치료시 설계용 CT와 초음파를 이용하여 방광의 부피를 측정하였고, 실험군에서는 방사선 치료 기간 동안 초음파로 매주 방광의 부피를 측정하였다. 결 과: 모의치료시 초음파로 측정한 방광의 부피와 CT로 측정한 방광의 부피는 유의한 상관성을 보여(r=0.679) 방광 부피를 측정하는 데 있어 초음파의 정확성을 확인하였다. 실험군에서 같은 양의 물을 마셔도 방광의 부피는 환자에 따라 차이가 컸고(범위 $22{\sim}352\;ml$), 방사선치료 기간 동안 방광의 부피는 일정하게 유지되지 않았다. 그러나 모의치료시 방광의 부피가 컸던 환자는 치료기간 중에도 방광의 부피가 큰 경향을 보였다. 실험군의 방광 부피는 평균 $299{\pm}155\;mL$이었고 대조군은 평균 $187{\pm}155\;ml$로, 일정량의 물을 마시면 방광 조절을 하지 않았을 때보다 방광 부피가 유의하게 증가하였고(p=0.009), 실험군에서 급성 비뇨기계 부작용이 대조군보다 감소하였지만 통계적으로 유의하지는 않았다 또한 방광의 부피가 클수록 부작용이 감소하는 경향을 보였고, 모의치료시 CT로 측정한 방광의 부피가 150 ml 이상이면 1등급과 2등급의 비뇨기계 부작용이 현저히 감소하였다(p=0.023). 치료 기간 중의 방광 부피에 따른 부작용 발생률은 통계적으로 유의한 변화를 보이지 않았으나 방광의 부피가 클수록 1등급 부작용이 감소하는 경향을 보였고, 100 ml 이상인 경우에는 모든 등급의 부작용이 감소하는 경향을 보였다. 결 론: 방광을 채우고 방사선치료를 할 때 치료 기간 중 방광의 부피가 일정하게 유지되지 않았음에도 불구하고 방광 조절을 하지 않았을 때보다 비뇨기계 급성 부작용이 감소하는 경향을 보였고, 모의치료시 방광 부피가 150 mL 이상인 경우 부작용은 현저히 감소하였다. 따라서 전립선암 환자에서 방사선치료를 할 때 방광을 채우는 것이 급성 비뇨기계 부작용을 줄이는 데 도움이 될 것으로 생각한다.

방사선치료 시 환자자세 검증을 위한 분석용 도구 개발 (Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images)

  • 이석;성진실;권수일;추성실;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.100-106
    • /
    • 2003
  • 목적 : 네트워크를 이용해 영상수집을 하여 방사선치료를 수행하는데 요구되는 기계중심점과 종양중심점의 일치여부 및 환자자세의 재현성을 확인하는 기능 등을 수행할 수 있는 환자자세검증도구를 개발하고자 한다. 대상 및 방법 : 전산화단층촬영 영상으로부터 재구성한 디지털화재구성사진(digitally reconstructed radiography, DRR) 영상과 투과 영상인 모의치료영상, 상용전자포탈 영상장치에서 수집한 포탈영상 밑 CCD 카메라로부터 획득한 디지털영상 등을 네트워크를 통해 수집하였고, 이를 조작할 수 있는 분석용 프로그램을 프로그램 제작툴인 IDL(IDL 5.4, Research systems, USA)을 이용해 작성하였다. 이를 환자자세 검증도구(patients setup verification tool for RT, PSVTS)라 명명하였다. 기계중심점과 종양중심점의 일치여부 확인은 전산화단층촬영영상으로부터 재구성한 DRR 영상과 모의치료영상을 이용하여 위치변위를 분석함으로써 치료조준오차를 구하였다. 환자자세의 재현성 확인은 첫 치료 시에 얻은 포탈 영상과 매 치료 시마다 얻는 포탈영상을 비교, 분석하는 방법과 디지털영상을 이용하는 방법을 사용하였다. 결과 : 방사선치료 시 요구되는 기계 중심점과 종양중심점의 일치여부 및 환자자세의 재현성을 확인할 수 있는 사용자편의방식의 소프트웨어와 환자자세검증도구를 개발하였다. 종양중심점과 기계중심점의 일치여부 확인 결과 치료조준오차는 두경부에서 전후, 좌우 각각 0.8$\pm$0.2 mm, 1.0$\pm$0.3 mm이었고, 골반부에서 1.1$\pm$0.5 mm, 1.0$\pm$0.6mm이었다. 환자자세 재현성은 영상을 실시간으로 획득하여 환자 자세 위치 변화를 시각적으로 평가할 수 있어실용성 있음을 알 수 있었다. 결론 : 환자자세의 재현성 및 종양중심점과 기계중심점의 일치여부를 파악할 수 있는 환자자세검증도구를 개발하였고, DRR 영상의 질 증진, 사용자편의방식의 소프트웨어를 보완한다면 임상응용에 가능할 것으로 사료된다.

간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정 (Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma)

  • 금기창;이상욱;신현수;김귀언;성진실;이창걸;추성실;장세경;서창옥
    • Radiation Oncology Journal
    • /
    • 제18권2호
    • /
    • pp.107-113
    • /
    • 2000
  • 목적 : 간암의 3차원 입체조형치료계획시 electronic portal imaging device (EPID)를 이용한 검증영상으로 경계여유 결정에 필요한 객관적 기초자료를 얻으므로써 방사선치료의 정확성을 높이고 본 기기를 이용하여 방사선치료의 정도관리 측면에서의 유용성을 알아보고자 하였다. 대상 및 방법: 10명의 간암 환자에서 EPID를 이용하여 1회 방사선 치료 중 약 4극회의 검증영상을 획득하였고 총 10회 분할 치료기간 동안 반복하여 시행하였다. 방사선치료 자세 고정시 발생할 수 있는 각 개인의 자세 오차를 구하여 치료간 발생하는 환자의 위치 이동을 분석하였고, 호흡으로 인한 간의 상하 움직임의 정도를 측정하여 계획용표적체적(Planning Target Volume, PTV)의 결정시 필요한 적정 경계 여유를 구하였다. 결과 : 검증영상 분석 결과 간암의 치료시 자세이동에 의한 자세 오차는 x축으로 3.0 mm, 표준편차는 1.70 mm 였고 y축으로 3.7 mm, 표준편차 1.88 mm 였다. 따라서 각 축을 중심으로 5 mm 이내였다. 또한 호흡에 의한 간의 상하 운동 범위는 평균 8.63 mm이었고 표준편차는 1.48 mm 였다. 따라서 계획용표적체적 결정시 종양에 적어도 15 mm의 경계여유가 더 필요하다 결론 : EPID는 3차원 입체조형치료계획시 종양의 경계여유 결정에 매우 유용하며 나아가서 방사선치료의 정도관리에도 크게 기여할 것이다

  • PDF