Patients Setup Verification Tool for RT (PSVTS) : DRR, Simulation, Portal and Digital images |
Lee Suk
(Department of Medical Physics, Kyonggi University)
Seong Jinsil (Brain Korea 21 Project for Medical Science) Kwon Soo I1 (Department of Medical Physics, Kyonggi University) Chu Sung Sil (Department of Radiation Oncology, Collage of Medicine, Yonsei University) Lee Chang Geol (Department of Radiation Oncology, Collage of Medicine, Yonsei University) Suh Chang Ok (Department of Radiation Oncology, Collage of Medicine, Yonsei University) |
1 | Herman MG, Abrams RA, Mayer RR. Clinical use of on-line portal imaging for daily patient treatment verification. Int J Radiat Oncol Biol Phys 1994;28:1017-1023 DOI PUBMED ScienceOn |
2 | Curtin-Savard A, Podgorsak EB. An electronic portal imaging device as a physics tool. Medical Dosimetry 1997;22:101-105 DOI ScienceOn |
3 | 조병철, 오도훈, 배훈식. 디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인. 대한방사선종약학회지 1999;17:84-88 |
4 | Hilt G, Wolf D, Aletli P. Preprocessing of control portal images for patient setup verification during the treatments in external radiotherapy. Med Phys 1999;26:2539-2549 DOI ScienceOn |
5 | Hendee WR, Trueblood JH. Digital Imaging. American Association of Physicists in Medicine by Medical Physics Publishing Corporation, 1993:195-280 |
6 | See A, Kron T, Johansen J, et al. Decision-making models in the analysis of portal films: a clinical pilot study. Australasian Radiology 2000;44:72-83 DOI ScienceOn |
7 | Lujan A, Balter M, Haken RK. Determination of rotations in three dimensions using two-dimensional portal image registration. Med Phys 1998;25:703-708 DOI ScienceOn |
8 | Zhu Y, Jiang XQ, van Dyk J. Portal dosimetry using a liquid ion chamber matrix: dose response studies. Med Phys 1995;22:1101-1106 DOI ScienceOn |
9 | ICRU Report 50: Prescribing, Recording and Reporting Photon Beam Therapy. International Commission in Radiation Units and Measurements, Bethesda, MD (1993) |
10 | S Lee, HS Chang, EK Choi et al. On-line quality assurance of linear accelerator with electronic portal imaging system. Med Phys 1998;25:1582 |
11 | Siddon RL. Fast calculation of the exact radiological path for a three-dimensional CT array. Med Phys 1985;12:138-144 |
12 | Sirois LM, Hristov DH, Fallone BG. Three-dimensional anatomy setup verification by correlation of orthogonal portal images and digitally reconstructed radiographs. Med Phys 1999;26:2422-2428 DOI ScienceOn |
13 | Gilhuijs KA, Vijlbrief RE. Optimization of automatic portal image analysis. Med Phys 1995;22:1089-1099 DOI ScienceOn |
14 | S Lee, BY Yi, JG Cho, et al. Geometrical QC/QA for medical linear accelerator using electronic portal imaging device (EPID). Korean Journal of Medical Physics 1997;8:59-65 |
15 | ohnson LS, Miliken BD, Hadley SW, et al. Initial clinical experience with a video-based patient positioning system. Int J Radiat Oncol Biol Phys 1999;45:205-213 |
16 | Luchka K, Chen D, Shalev S. Assessing radiation and light field congruence with a video based electronic portal imaging device. Med Phys 1996;23:1245-1252 DOI ScienceOn |
17 | Lemieux L, Kitchen ND, Thomas DGT. A patient-tocomputed tomography image registration method based on digitally reconstructed radiographs. Med Phys 1994;21:1749-1760 DOI ScienceOn |
18 | S Lee, DH Lee, MS Kim et al. On-line setup verification for fractionated stereotactic radiotherapy (FSRT) using electronic portal imaging device (EPID) system: DRR, simulation image vs. portal image. Int J Radiat Oncol Biol Phys 2000:48:344 |
19 | Hristov DH, Fallone BG. A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs. Med Phys 1996;23:75-84 DOI ScienceOn |
20 | Hashimoto S, Shirato H, Nishioka T, et al. Remote verification in radiotherapy using digitally reconstructed radiography (DRR) and portal images: a pilot study. Int J Radiat Oncol Biol Phys 2001;50:579-585 DOI ScienceOn |
21 | Gilhuijs KGA, van de Ven PJH, van Herk M. Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data. Med Phys 1996;23:389-399 DOI ScienceOn |
22 | Hatherly KE, Smylie J, Rodger A. A comparison of fieldonly electronic portal imaging hard copies with double exposed port films in radiation therapy treatment setup confirmation to determine its clinical application in a radiotherapy center. Int J Radiat Oncol Biol Phys 1999;45:791-796 DOI ScienceOn |
23 | Boxwala AA, Chaney EL, Fritsch DS, et al. Comparison of computer workstation with light box for detecting setup errors from portal images. Int J Radiat Oncol Biol Phys 1999;44:711-716 DOI PUBMED ScienceOn |
24 | Hatherly KE, Smylie JC, Rodger A, et al. A double exposed portal image comparison between electronic portal imaging hard copies and port films in radiation therapy treatment setup confirmation to determine its clinical application in a radiotherapy center. Int J Radiat Oncol Biol Phys 2001;49:191-198 DOI PUBMED ScienceOn |