• 제목/요약/키워드: thermal vacuum

검색결과 1,509건 처리시간 0.035초

지구 정지궤도 위성의 열해석 모델 보정 (THERMAL MODEL CORRELATION OF A GEOSTATIONARY SATELLITE)

  • 전형열;김정훈
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.59-65
    • /
    • 2011
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and was developed by KARI for communication, ocean and meteorological observations. COMS was tested under vacuum and very low temperature conditions in order to correlate thermal model and to verify thermal design. The test was performed by using KARI large thermal vacuum chamber. The COMS S/C thermal model was successfully correlated versus the 2 thermal balance test phases. After model correlation, temperatures deviation of all individual units were less than $5^{\circ}C$ and global deviation and standard deviation also satisfied the requirements, less than $2^{\circ}C$ and $3^{\circ}C$. The final flight prediction was performed by using the correlated thermal model.

정지궤도위성 전장품의 열설계 검증을 위한 최적 열해석 모델링 연구 (A Study on Optimized Thermal Analysis Modeling for Thermal Design Verification of a Geostationary Satellite Electronic Equipment)

  • 전형열;양군호;김정훈
    • 대한기계학회논문집B
    • /
    • 제29권4호
    • /
    • pp.526-536
    • /
    • 2005
  • A heat dissipation modeling method of EEE parts, or semi-empirical heat dissipation method, is developed for thermal design and analysis an electronic equipment of geostationary satellite. The power consumption measurement value of each functional breadboard is used for the heat dissipation modeling method. For the purpose of conduction heat transfer modeling of EEE parts, surface heat model using very thin ignorable thermal plates is developed instead of conventional lumped capacity nodes. The thermal plates are projected to the printed circuit board and can be modeled and modified easily by numerically preprocessing programs according to design changes. These modeling methods are applied to the thermal design and analysis of CTU (Command and Telemetry Unit) and verified by thermal cycling and vacuum tests.

Commissioning result of the KSTAR in-vessel cryo-pump

  • Chang, Y.B.;Lee, H.J.;Park, Y.M.;Lee, Y.J.;Kwag, S.W.;Song, N.H.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, N.W.;Yang, H.L.;Oh, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.53-58
    • /
    • 2013
  • KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to $LN_2$ one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

우주진공환경에서의 마이크로 추진 (Micro Propulsion under High Altitude Space Environments)

  • 정성철;허환일
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.405-408
    • /
    • 2008
  • From the previous researches about flow characteristic of micro-nozzle, we found that viscosity and back pressure induced heavy losses in micro nozzle. To overcome thess losses, we began to study new conceptual micro propulsion system that is thermal transpiration based micro propulsion system. It has no moving parts and can pump the gaseous propellant by temperature gradient only (cold to hot). Most of previous research on thermal transpiration is in its early stage and mainly studied for application to small vacuum facility or gas chromatography in ambient condition using nanoporous material like aerogel. In this study, we focus on basic research of propulsion system based on thermal transpiration using polyimide material in vacuum conditions.

  • PDF

인공위성 전장품의 열설계 검증을 위한 해석 및 실험적 연구 (An Analysis and Experimental Study for Thermal Design Verification of Satellite Electronic Equipment)

  • 김정훈;전형열;양군호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.91-95
    • /
    • 2005
  • A heat dissipation modeling method of EEE parts is developed for thermal design and analysis of an satellite electronic equipment. The power consumption measurement value of each functional breadboard is used for the heat dissipation modeling method. For the purpose of conduction heat transfer modeling of EEE parts, surface heat model using very thin ignorable thermal plates is developed instead of conventional lumped capacity nodes. The thermal plates are projected to the printed circuit board and can be modeled and modified easily by numerically preprocessing programs according to design changes. These modeling methods are applied to the thermal design and analysis of CTU and verified by thermal cycling and vacuum tests.

  • PDF

STM 열진공 시험 결과를 이용한 EOS-C Ver.3.0 열제어계 설계 검증 (Design Verification of Thermal Control Subsystem for EOS-C Ver.3.0 using STM Thermal Vacuum Test Result)

  • 장진수;양승욱;정연황
    • 한국항공우주학회지
    • /
    • 제38권12호
    • /
    • pp.1232-1239
    • /
    • 2010
  • (주)쎄트렉아이는 지구관측위성의 주 탑재체로 사용될 고해상도 전자광학카메라, EOS-C Ver.3.0을 개발 중이다. EOS-C Ver.3.0은 현재 운용중인 DubaiSat-1의 주 탑재체인 EOS-C Ver.2.0 개발 경험을 바탕으로 능동 열제어 방식과 수동 열제어 방식을 적절하게 혼용하여 보다 향상된 성능을 갖도록 설계되었다. 설계를 바탕으로 STM을 개발하여 인증(qualification) 수준의 열진공 시험을 수행하여 설계 여유(design margin)를 확인하였다. 또한 열평형 시험 결과를 이용하여 열제어계 설계에 사용한 열-수치 모델에 대한 검증 작업을 수행하였으며, 열-수치 모델이 실제 열적 특성을 잘 모사하고 있음을 확인하였다.

EOS-C Ver.3.0 비행모델의 열제어계 개발 및 설계 검증 (Development and Design Verification of Thermal Control Subsystem for EOS-C Ver.3.0 Flight Model)

  • 장진수;양승욱;김이을
    • 한국항공우주학회지
    • /
    • 제40권10호
    • /
    • pp.872-881
    • /
    • 2012
  • (주)쎄트렉아이는 지구관측위성의 주 탑재체로 사용될 고해상도 전자광학카메라, EOS-C Ver.3.0의 FM 개발을 완료하였다. EOS-C Ver.3.0 FM은 STM 열진공 시험 결과를 이용한 설계 최적화를 통해 STM 대비 향상된 열제어 성능을 갖도록 설계되었다. FM 개발 후, 인수(acceptance) 수준의 열진공 시험 수행을 통해 작업도(workmanship) 확인을 완료하였다. 또한 열평형 시험 결과를 이용하여 열-수치 모델에 대한 검증 작업을 수행, 열-수치 모델이 EOS-C Ver.3.0 FM의 실제 열적 특성을 잘 모사하고 있음을 확인하였다.

PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구 (An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

Dichlorosilane Gas를 이용한 High Temperature Oxide Thin Film의 특성 (Characteristics of High Temperature Oxide Thin Film Using Dichlorosilane Gas)

  • 이승석;이석희;김종철;박헌섭;오계환
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.190-197
    • /
    • 1992
  • In this study we have investigated physical and electrical properties of high temperature oxide (HTO) thin film using dichlorosilane (DCS) gas. This film had low etch rate and excellent step coverage, and its characteristics of Si-O bond were similar to those of thermal oxide. I-V curves also showed similar electrical properties to those of thermally grown oxide (SiO2) while time dependent dielectric breakdown (TDDB) results revealed 1/4 value of thermal oxide. However, defect density was measured to be much lower value than that of thermal oxide.

  • PDF

반실험적 열소산 방법을 이용한 위성용 전장품 열해석 (A SATELLITE ELECTRONIC EQUIPMENT THERMAL ANALYSIS USING SEMI-EMPERICAL HEAT DISSIPATION METHOD)

  • 김정훈;전형열;양군호
    • 한국전산유체공학회지
    • /
    • 제11권2호
    • /
    • pp.32-39
    • /
    • 2006
  • A heat dissipation modeling method of EEE parts is developed for thermal design and analysis of an satellite electronic equipment. The power consumption measurement value of each functional breadboard is used for the heat dissipation modeling method. For the purpose of conduction heat transfer modeling of EEE parts, surface heat model using very thin ignorable thermal plates is considered instead of conventional lumped capacity nodes. These modeling methods are applied to the thermal design and analysis of CTU EM and EQM and verified by thermal cycling and vacuum tests.