• 제목/요약/키워드: thermal disturbance

검색결과 76건 처리시간 0.026초

Intelligent Tuning of PID Controller With Disturbance RejectionUsing Immune Algorithm

  • Kim, Dong-Hwa;Cho, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.885-890
    • /
    • 2004
  • Strictly maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature, the change of the dynamic characteristics in the reheater. Up to the present time, PID Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on tuning of the Controller with disturbance rejection for thermal power plant using immune based multiobjective approach. An ITSE(Integral of time weighted squared error) is used to decide performance of tuning results.

  • PDF

화력발전소 보일러 드럼 수위 퍼지 제어 (Fuzzy control of drum level of boiler in thermal power plant)

  • 변승현;박두용;김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.195-198
    • /
    • 1996
  • The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant setpoint regardless of disturbance such as main steam flow. The initial response of the drum level loop process is in a direction opposite to the final response. The drum level loop shows inverse response when the power is changed abruptly. We adopt fuzzy controller using knowledge base considering system dynamics for controlling drum level. Finally, the simulation result using the digital simulator for boiler system in Seoul Power Plant Unit 4 shows the validity of fuzzy controller.

  • PDF

연속식 공중합 반응기의 모델링 및 제어기 설계 (Modeling and controller design for a continuous copolymerization reactor)

  • 황우현;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.788-791
    • /
    • 1996
  • A mathematical model is developed for thermal solution copolymerization of styrene and acrylonitrile in a continuous stirred tank reactor(CSTR). Computational studies are carried out with the continuous copolymerization system model developed in this work to give the monomer conversion, copolymer composition and the average molecular weights of the copolymer. By performing the dynamic analysis of the reaction system, the polymer properties against the changes in the operating conditions are determined quantitatively. The cascade PID and fuzzy controller show satisfactory performances for both set point tracking and disturbance rejection. Especially, the fuzzy controller is superior to the PID controller.

  • PDF

화력발전소의 과열기증기의 온도제어 (Temperature Control of Superheater Steam in Thermal Power Plant)

  • 신휘범;이순영
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2006-2011
    • /
    • 2010
  • The superheater in the thermal power plant makes the wet steam into the dry steam with high temperature and high pressure by using the boiler heat. The dry steam pressure rotates the turbine-generator system. The efficiency and life time of the boiler heavily depends on the steam temperature regulation. The steam temperature can be deviated from the reference by the MW demand of the power plant. It is therefore required that the PI(proportional-integral) controller should be robust against the disturbance such as the MW demand. In this paper, the PI controller with the integral state predictor is proposed and applied to regulate the steam temperature of the superheater, and it is compared with the conventional PI controller operated in the thermal power plant in view of control performance.

등온 수평 평판 위를 지나는 층류유동 의 열적 불안전성 및 열전달 상관관계 (Thermal Instability and Heat Transfer Correlations of Laminar Flow over Isothermal Horizontal Flat Plate)

  • 박병완;유정열;최창균;노승탁
    • 대한기계학회논문집
    • /
    • 제9권5호
    • /
    • pp.613-620
    • /
    • 1985
  • 본 연구의 목적은 수평 Blasius유동의 열적 불안정성 문제에서 유동방향 좌표 에도 의존하는 교란양을 최초로 도입함으로써 보다 합리적인 안정성 해석을 수행하고 그 결과를 기존의 실험적 및 이론적인 자료들과 비교하며 이를 토대로 한 보다 실제적 인 열전달 상관관계를 얻고자 하는데 있다.

등온 으로 가열되는 수평 평판위 를 지나는 블라시우스 유동 의 와류불안정성 해석 (An Analysis on Vortex Instability of Blasius Flow Over Isothermally Heated Horizontal Plates)

  • 이형인;최창균;유정열
    • 대한기계학회논문집
    • /
    • 제6권4호
    • /
    • pp.390-396
    • /
    • 1982
  • The onset of longitudinal vortices in horizontal Blasius flow isothermally heated from below is studied analytically. The assumption that at the onset of thermal instability the thermal disturbances are confined within the thermal boundary layer is employed for the limiting case of large Prandtl number. Polynomial representations for the basic quantities obtained by the integral method of the boundary layer analysis have been used. Then the system of differential equations and boundary conditions for disturbance quantities is reformulated in a convenient form so that the solutions may be constructed as rapidly convergent power series. The critical buoyancy parameter G $r_{x}$ $^{*}$ /R $e^{*1.5}$ falls between 2 and 6, which is about one order of magnitude lower than the existing experimental values. It is also shown that the positions of the onset of instability can be closely predicted by the present theory.y.y.

화력 발전소 보일러 드럼수위 제어기의 자동 동조 (Auto-tuning of boiler drum level controller in Thermal Power Plant)

  • 이주현;주영호;변승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2584-2586
    • /
    • 2000
  • A drum level control is one of the most important control systems in thermal power plant. The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant set-point regardless of disturbance such as main steam flow. The implemented drum level controller is the cascade PI controller. The important factor in drum level controller is the parameters of two PI controllers. The tuning of PI controller parameter is tedious and time-consuming job. In this paper, the relay feedback Ziegler - Nichols tuning method extended to auto-tune cascade PI drum level controller. Finally, the simulation result using boiler model in Power Plant shows the validity of auto-tuned cascade PI controller.

  • PDF

전산해석을 통한 고압열증기압축기 형상변수에 관한 강건 설계 (Robust Design for Shape Parameters of High Pressure Thermal Vapor Compressor by Numerical Analysis)

  • 박일석
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.931-937
    • /
    • 2008
  • A high motive pressure thermal vapor compressor(TVC) for a commercial multi-effect desalination(MED) plant is designed to have a high entraining performance and its robustness is also considered in the respect of operating stability at the abrupt change of the operating pressures like the motive and suction steam pressure which can be easily fluctuated by the external disturbance. The TVC having a good entraining performance of more than entrainment ratio 6.0 is designed through the iterative CFD analysis for the various primary nozzle diameter, mixing tube diameter and mixing tube length. And then for a couple of TVC having a similar entrainment ratio, the changes of the entrainment ratio are checked along the motive and suction pressure change. The system stability is diagnosed through the analyzing the changing pattern of the entrainment ratio.

냉매압축기 성능시험장치의 제어 특성 (Control characteristics of a refrigerant compressor test facility)

  • 이진영;이대영;김광호;남평우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.46-51
    • /
    • 1999
  • This paper describes the control charcteristics of thermal/flow systems. In thermal/flow systems, the transport lag plays as a dead time causing a deterioration of the controllability. Besides this, such many parameters including the temperature, pressure, and flow rate affect the system response that a control scheme which can deal with multi-input is required. Particularly in a refrigerant compressor test facility, the evaporator and condenser interact each other so that the change in the evaporator pressure cause the condenser pressure to change or vice versa. Therefore, to control the evaporator pressure, not only the cooling water flow rate in the evaporator but also the coolant flow rate in the condenser is considered. Meanwhile, the conventional PID controllers, which is suitable for a single input system, shows a large overshoot for a disturbance input. In this work, the predictive control scheme is introduced and its applicability is discussed for thermal/flow systems.

  • PDF

고온 초전도체 팬케이크 코일의 퀜치 해석 (Quench Analysis in HTS Pancake Coil)

  • 박차식;안태길;박경우;김도형;차귀수;서정식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.6-9
    • /
    • 2009
  • The thermal characteristics of quench propagation is a crucial problem for the stability of the superconductor. The objective of this study is to simulate the quench propagation with the variation of disturbance energy in Bi-2223/Ag HTS pancake coil. In this analysis, the temperature-time trace of a point away from heater was calculated under conditions of different quench energy. The critical disturbance energy between quench propagation and quench recovering was calculated, In addition, the minimum quench energy with different transport currents was obtained through the present simulation. These results are significant to the application of HTS.