• Title/Summary/Keyword: tester device

Search Result 98, Processing Time 0.03 seconds

Thermo-ompression Process for High Power LEDs (High Power LED 열압착 공정 특성 연구)

  • Han, Jun-Mo;Seo, In-Jae;Ahn, Yoomin;Ko, Youn-Sung;Kim, Tae-Heon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.4
    • /
    • pp.355-360
    • /
    • 2014
  • Recently, the use of LED is increasing. This paper presents the new package process of thermal compression bonding using metal layered LED chip for the high power LED device. Effective thermal dissipation, which is required in the high power LED device, is achieved by eutectic/flip chip bonding method using metal bond layer on a LED chip. In this study, the process condition for the LED eutectic die bonder system is proposed by using the analysis program, and some experimental results are compared with those obtained using a DST (Die Shear Tester) to illustrate the reliability of the proposed process condition. The cause of bonding failures in the proposed process is also investigated experimentally.

A Study on the Three Phase ZCS(Zero Current Switching) Inverter using Auxiliary Circuit (보조회로를 이용한 3상 ZCS 인버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Kim, Pill-Soo;Choi, Geun-Soo;Lee, Taeck-Kie
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.209-212
    • /
    • 2003
  • This paper proposes a soft-transition control strategy for a three phase ZCS(Zero Current Switching) inverter circuit. Each phase leg of inverter circuit consists of an LC resonant tank, two main switches, and one auxiliary switches. This paper presents design consideration via a study example of a three phase prototype inverter for motor drives. A simple device tester with zero current switching capability is proposed to select eligible auxiliary switches. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 2.2kW 5kHz IGBT based experimental circuit.

  • PDF

Characteristic Analysis and Experiment of Pneumatic Servo Valve (공기압 서보밸브 특성해석 및 실험)

  • Kim, Dong-Soo;Lee, Won-Hee;Choi, Byung-Oh
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.967-973
    • /
    • 2004
  • Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve.

  • PDF

A study on the circuit design for DC characteristic inspection of semiconductor devices (반도체 소자의 DC 특성 검사용 회로설계에 관한 연구)

  • 김준식;이상신;전병준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.105-114
    • /
    • 2004
  • In this paper, we design the circuits for DC parameter test of semiconductor devices. The DC parameter tester is the system which inspects the DC parameters of semiconductor devices. In the designed circuits, voltage(current) forcing current(voltage) sensing methods are used to inspect the parameters. The designed circuits are simulated by OR-CAD. The simulation results have good performance.

Research on the Electric device for the Noncontacting Hardness Tester (비접촉식 경도 측정용 전기 설비에 관한 연구)

  • 이진락;백기남
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.45-47
    • /
    • 1991
  • In this research, we verify the relations between the mechanical hardness of a strip and the output of Residual Magnetic Flux Detector, which is installed in the end side of #2 CAL. First, we install the strip speed detector and get a hardness signal and a speed signal 2 seconds, and then do signal processing and send an output to a printer every 30 seconds. The system that performs above functions is Magnetic Hardness Data Acquisition & Processing System. We got the relation between output current and hardness for the strip of T3 BP through on-line tests. Seconds, we made a hardness Measurement Simulator and observed the speed characteristics of residual magnetic flux, with using it.

  • PDF

The Local Surface Strength Variation of Coated Papers during Printing (인쇄과정에서 코팅 용지의 국부적인 표면강도 변화에 관한 연구)

  • Youn, Jong-Tae
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.22 no.2
    • /
    • pp.101-110
    • /
    • 2004
  • The local surface strength variation of coated papers were measured at various speeds on a number of coated paper samples to study the effects of speed and ink tack on coating pick. Coating pick phenomenon is observed in an ink transfer variation curve as a decrease in the slope of the curve. On the other hand, it causes an actual decrease in net ink transfer to paper with an increase in speed. The effect of speed on coating pick depends on ink tack, ink film thickness and surface properties of coating layer formation of paper. A novel device to measure the surface strength can rate the coating paper in a different order. Comparison are made between dry test of coating paper pick and wet coating pick test of printing in IGT printability tester. Coating formulation is the main key to prevent from coating pick. The binder level increases, the coating pick and the slop decrease. The piling on blanket in printing is a problem when the coating pick is occur on a local area rather than average surface strength of coated papers.

  • PDF

A Study on the Effects of the Period Control Device of Anti-Rolling Tanks (감요수조의 주기조절 장치 효과에 관한 연구)

  • 유재문;김효철;이현엽
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The effect of the passive anti-rolling tanks(ART) decreases when the roll period of the vessel does not match the designed oscillating period of the fluid in the tank. In order to improve the effect of the passive ART, the damping plates are installed in the lower duct of the ART to adjust the oscillating period of the fluid. The effects of the damping plates on the oscillating period of the fluid and the changes of the stabilizing moments are examined through the series of bench tests. Acryl model tank larger than 1m breadth is made to minimize the viscous effect of the tank and the stabilizing moments of the tank are measured for various roll angles. Using the obtained tank damping coefficient, RAO(Response Amplitude Operator) value in the resonance range is computed and the stabilizing effect of a ART has been estimated.

A Study on the Three Phase Inverter using Auxiliary Switches (보조 스위치를 이용한 3상 ZCS 인버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.155-158
    • /
    • 2004
  • This paper proposes a soft-transition control strategy for a three phase ZCS(Zero Current Switching) inverter circuit. Each phase leg of inverter circuit consists of an LC resonant tank, two main switches, and two auxiliary switches. This paper presents design consideration via a study example of a three phase prototype inverter for motor drives. A simple device tester with zero current switching capability is proposed to select eligible auxiliary switches. The principle of operation, feature and design consideration is illustrated and verified through the experiment with a 2.2kW 5kHz IGBT based experimental circuit.

  • PDF

Thermal Shock Resistance of $Al_{2}O_{3}$- and Fe-$Al_{2}TiO_{5}$-based Castable Refractories

  • Liu, T.;Latella, B.A.;Bendeich, P.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.345-351
    • /
    • 1998
  • Thermal shock resistance of $Al_2O_3$- and Fe-$Al_2TiO_5$-based Castable Refractories was studied using a central heating technique. Ring type specimens, 10mm thick and 20 and 100mm inner and outer diameters, respectively, were rapidly heated on the internal surface of the centre hole using a high power electrical heating element. The temperature field was measured experimentally and modelled using finite element analysis (FEA). The thermal stress field was also modelled using FEA. A radial notch was introduced to the ring specimens to enable calculation of the thermal stress intensity factors (SIF). A special LVDT device was incorporated in the thermal shock tester to monitor crack mouth opening displacement (COD). The thermal shock fracture initiation and crack propagation behaviour of the castable refractories were ascertained using the COD measurements and the fracture mechanics analysis data.

  • PDF

Study on Salt-Proof Characteristics of Copper Clad Aluminum (동복알루미늄의 내염특성 연구)

  • Kim, Jin-Sa;Bae, Duck-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1764-1768
    • /
    • 2009
  • As the demand of electric power is increasing rapidly, the need of the compact and light electric power device is also increased. Copper clad aluminum (CCA) is newly proposed electrical conductor, because of its light-weight and low-cost characteristics, to replace the existing conductor made of copper. This paper presents the salt-proof characteristics of the copper clad aluminum (CCA) to certificate long time safe operation of the newly proposed electrical conductor. The two types of the CCA conductor were tested in the neutral salt spray tester. The experimental results of two types of the CCA with salt spray were presented in this paper. The results comprise resistance measured data, micro picture of the selected surface, and component measured data according to the elapsed time. The period of the experiment was 1,000 hours. There was no evidence to show the corrosion of CCA during the whole period of the experiments.