• Title/Summary/Keyword: tester channel

Search Result 11, Processing Time 0.03 seconds

The timing do-skew modeling and design in a high speed digital system (고속 디지털 시스템에서 전달 시간차의 보정 모델링 및 구현)

  • Oh, Kwang-Suhk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.601-604
    • /
    • 2002
  • In this paper, the timing do-skew modeling for a high speed logic tester channels is developed. The time delay of each channel in a logic tester are different from other channels and it can produce timing error in a test. To get the best timing accuracy in the test with a logic tester, the timing skew must be compensated. The timing skew of channels is due to the difference of time delay of pin-electronics devices composing channels and length of metal line placed on PCB. The expected timing difference of channels can be calculated according to the specifications of pin electronics devices and strip line modeling of PCB. With the calculated delay time, the timing skew compensation circuit has been designed. With the timing skew compensation circuit, the timing calibration of a logic tester can be peformed easily and automatically without other time measuring instruments. The calibration method can then be directly applied to logic testers in mass production lines.

  • PDF

Design of Tester Apparatus for 48 Channel GM Tube Sensor (48개 채널의 GM Tube 센서 테스터 장치의 설계)

  • Lee, Hee-Yeol;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.310-313
    • /
    • 2016
  • In this paper, we propose the tester apparatus for 48 channel GM Tube sensor. The proposed apparatus can test up to 48 channel GM tube simultaneously to detect the defect and analyze the sensor characteristic. 300-1000V variable high voltage generation circuit is utilized for the apparatus suitable for the sensor characteristic. Thus, the proposed system is useful for various GM Tube sensor characteristic analysis. Multiple sensor testing environment is established for the early detection of the defect and the analysis to reduce the costs for manufacturing and rework. Developed 48 channel GM Tube sensor test is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.

New Test Methods of Retention and Drainage Using Multi-channel Turbidimeter and Balance Recorder

  • Son, Dong-Jin;Kim, Bong-Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.5 s.118
    • /
    • pp.31-37
    • /
    • 2006
  • This study was performed to find effective measuring methods of retention and drainage by comparing traditional measuring methods of Britt jar, Canadian standard freeness tester methods and recently developed RDA-HSF with multi-channel turbidimeter method. At the result, Multi-channel turbidimeter method was useful to measure retention and efficiency of multiple chemical dosing system. A system CSF equipped with the balance recorder was also useful to obtain dynamic drainage information including initial drainage rate and final drainage amount. Therefore, we consider these new measuring systems would be helpful to advance retention and drainage technology.

SOC Test Compression Scheme Sharing Free Variables in Embedded Deterministic Test Environment

  • Wang, Weizheng;Cai, Shuo;Xiang, Lingyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.397-403
    • /
    • 2015
  • This paper presents a new SOC test compression scheme in Embedded Deterministic Test (EDT) compression environment. Compressed test data is brought over the TAM from the tester to the cores in SOC and decompressed in the cores. The proposed scheme allows cores tested at the same time to share some test channels. By sharing free variables in these channels across test cubes of different cores decompressed at the same time, high encoding efficiency is achieved. Moreover, no excess control data is required in this scheme. The ability to reuse excess free variables eliminates the need for high precision in matching the number of test channels with the number of care bits for every core. Experimental results obtained for some SOC designs illustrate effectiveness of the proposed test application scheme.

A Study of Micro-Channel Fabrication by Micro-Milling and Magnetic Abrasive Deburring (마이크로 밀링과 자기디버링을 적용한 마이크로 유동채널 가공)

  • Kwak, Tae-Kyung;Kwak, Jae-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.899-904
    • /
    • 2011
  • This This study aims to verify burr formation and to remove the burrs in micro-channel fabrication using micro-machining tools. The machining processes are combined with micro-milling and magnetic abrasive deburring for AISI316 stainless steel. Depending on the micro-milling conditions that are applied, burrs are formed around the side walls. Magnetic abrasive deburring is used to remove these burrs. AISI316 stainless steel is a nonferrous material and its magnetic flux density, which is an important parameter for efficient magnetic abrasive deburring, is low. To enhance this magnetic flux density, we design and build a magnetic array table. The effect of removing burrs is evaluated via SEM and a surface tester.

Test Results of Friction Factor for Round-Hole Roughness Surfaces in Closely Spaced Channel Flow of Water

  • Ha, Tae Woong
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1849-1858
    • /
    • 2004
  • For examining friction-factor characteristics of round-hole pattern surfaces which are usually applied on damper seals, flat plate test apparatus is designed and fabricated. The measurement method of leakage and pressure distribution along round-hole pattern specimen with different hole area is described and a method for determining the Fanning friction factor is discussed. Results show that the round-hole pattern surfaces provide a much larger friction factor than smooth surface, and the friction factor vs. clearance behavior yields that the friction factor generally decreases as the clearance increases unlike the results of Nava's flat plate test. As the hole depth is decreased, the friction factor is increased, and maximum friction factor is obtained for 50% of hole area. Since the present experimental friction factor results show coincident characteristics with Moody's friction factor model, empirical friction factors for round-hole pattern surfaces are obtained by using the Moody's formula based on curve-fit of the experimental data. Results of Villasmil's 2D CFD simulation support the present experimental test result.

The Development of Multi-channel Temp & Humi Distribution Tester (다채널 온습도 측정기 개발)

  • 김성환;지용주;이성수;김태훈;김묘향;한화택
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.211-215
    • /
    • 2001
  • 실내나 의복내 열적쾌적성을 평가하기 위해서는 정밀하고, 안정성이 높으며 빠른 응답특성을 갖는 센서와 측정시스템이 필요하다. 더욱이 의복내의 온도를 측정하기 위해서는 소형, 경량으로 인체에 부착하기 쉬워야하며 측정기의 부착이 피험자에게 부담을 주어서는 안된다. 본 연구에서는 이러한 요구사항을 만족할 수 있으면서도 이동이 자유롭고 장시간 측정이 가능한 큰 Data 저장용량, 실시간 측정 기능, 손쉬운 온습도 변환장치등을 갖춘 의복내 및 실내 온습도 측정등의 다양한 분야에 활용이 가능한 온습도 측정기와 이에 필요한 센서를 개발하고 개발된 측정기의 선형특성을 평가하였다.

  • PDF

Thermal and Mechanical Properties of Poly(lactic acid) Specimens Fabricated by Various Equal-channel Angular Extrusion Processes (다양한 방식의 등통로각압축공정으로 가공된 Poly(lactic acid) 시편들의 열 및 기계적 물성)

  • Liu, Xu-Yan;Jung, Si-In;Choi, Ho-Suk;Oh, Jun-Taek;Kim, Jong-Kuk
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.206-210
    • /
    • 2011
  • We fabricated rod-like poly(lactic acid)(PLA) specimens through applying various methods of equal-channel angular extrusion(ECAE) process and investigated the change of thermal and mechanical properties of specimens before and after each ECAE process. Combining three re-injection routes(A, BC, and C) and three pass counts(1, 2 and 4) allowed us to fabricate 7 different PLA specimens. Thermal properties of each specimen were measured by both differential scanning calorimeter and thermo-gravimetric analyzer. Shear strains of each specimen with respect to applied loads were measured by indentation hardness tester. Field emmision scanning electron microscopy was used to observe internal microstructure of cross-section of each specimen. The observed microstructures qualitatively supported the explanation of hardness test results. Among 7 specimens, PLA-P2A showed the biggest shear strain probably due to its dense microstructure.

A Design Experience of Propeller Open Water Testing Dynamometer (소형 프로펠러 단독시험기 설계)

  • J.S. Kim;M. Song;H. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.4
    • /
    • pp.48-54
    • /
    • 1995
  • A new propeller open water testing device is developed and tested in a tow tank. The devised dynamometer consists of a torque measuring part, a thrust measuring part and a driving motor with an RPM counter. Torque is designed to be measured directly from the torsion of the structure holding the motor by using strain gauges and, consequently, conventional slip ring is removed. Also, in order to make the device fit in relatively small model ships, the weight and the size of the whole integrated structure are reduced in various ways. The developed tester is proved to be easily utilized in small circulating water channel experiments and is believed to have provided us with essential information for future design of various types of conventional or object oriented force measuring device.

  • PDF

A Study on Big Data Processing Technology Based on Open Source for Expansion of LIMS (실험실정보관리시스템의 확장을 위한 오픈 소스 기반의 빅데이터 처리 기술에 관한 연구)

  • Kim, Soon-Gohn
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.2
    • /
    • pp.161-167
    • /
    • 2021
  • Laboratory Information Management System(LIMS) is a centralized database for storing, processing, retrieving, and analyzing laboratory data, and refers to a computer system or system specially designed for laboratories performing inspection, analysis, and testing tasks. In particular, LIMS is equipped with a function to support the operation of the laboratory, and it requires workflow management or data tracking support. In this paper, we collect data on websites and various channels using crawling technology, one of the automated big data collection technologies for the operation of the laboratory. Among the collected test methods and contents, useful test methods and contents useful that the tester can utilize are recommended. In addition, we implement a complementary LIMS platform capable of verifying the collection channel by managing the feedback.