• Title/Summary/Keyword: test procedures

Search Result 1,841, Processing Time 0.034 seconds

Development of Vehicle Evaluation System for Pedestrian Protection (보행자 보호를 위한 차량평가시스템 개발)

  • Yong, Boo-Joong;Cho, Hyun-Deog;Lee, Jae-Wan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.53-58
    • /
    • 2006
  • IHRA Pedestrian Working Group has investigated and analyzed the current status of pedestrian-vehicle accidents in IHRA member countries. According to the results, European countries and Japan are working on new regulations to improve passive pedestrian protection on passenger cars significantly. Although IHRA proposed pedestrian test procedures, which may provide a basis of technical regulations in the future, further research and development are necessary to refine the procedures. In order to prepare and satisfy the pedestrian protection requirements, domestic passenger vehicles also should be tested. Among various safety-related studies based on accident data analysis, dealing with pedestrian head injury would be considered one of the keen interests. In this study, the pedestrian headform impact test system is developed. The developed system will be useful to carry out validation study of the test procedures through actual tests using sample vehicles, and to explore the car feasibility level prior to the use of the test methods in legislation.

  • PDF

Nonparametric Procedures for Finding Minimum Effective Dose in a One-Way Layout

  • Kim, Hyeonjeong;Kim, Dongjae
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.3
    • /
    • pp.693-701
    • /
    • 2002
  • When the lowest dose level compared with zero-dose control has significant difference in effect, it is referred as minimum effective dose (MED). In this paper, we discuss several nonparametric methods for finding MED using updated rank at each sequential test step in small sample size and suggest new nonparametric procedures based on placement. Monte Carlo Simulation is adapted to compare power and Familywise Error Rate(FWE) of the new procedures with those of discussed nonparametric tests for finding MED.

A Comparison of Distribution-free Two-sample Procedures Based on Placements or Ranks

  • Kim, Dong-Jae
    • Journal of the Korean Statistical Society
    • /
    • v.23 no.1
    • /
    • pp.135-149
    • /
    • 1994
  • We discussed a comparison of distribution-free two-sample procedures based on placements or ranks. Iterative asymptotic distribution of both two-sample procedures is studies and small sample Monte Carlo simulation results are presented. Also, we proposed the Hodges-Lehmann type location estimator based on linear placement statistics.

  • PDF

A note on the sample size determination of sequential and multistage procedures

  • Choi, Kiheon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.6
    • /
    • pp.1279-1287
    • /
    • 2012
  • We particularly emphasized how to determine the number of replications with sequential and multistage procedures. So, the t-test is used to achieve some predetermined level of accuracy efficiently with loss function in the case of normal, chi-squared, an exponential distributions. We provided that the relevance of procedures are sequential procedure, two-stage procedure, modified two-stage procedure, three-stage procedure and accelerated sequential procedure. Monte Carlo simulation is carried out to obtain the stopping sample size that minimizes the risk.

A Study on The Application of ISO/IEC 17025 Software Accredited Testing Institute Using ISO/IEC/IEEE 29119 and ISO/IEC 25023 (ISO/IEC/IEEE 29119와 ISO/IEC 25023을 이용한 ISO/IEC 17025 소프트웨어 공인시험기관 적용에 관한 연구)

  • Lee, Chang-Hee;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Kim, Myung-Sup;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.97-106
    • /
    • 2020
  • The purpose of this study is to determine how to apply ISO/IEC/IEEE 29119 software test procedures and ISO/IEC 25023 software test evaluation items to software-accredited testing laboratories based on the ISO/IEC 17025 international standard requirements. As a method, the overall requirements for their application to a test laboratory were analyzed by mapping ISO/IEC/IEEE 29119 and ISO/IEC 25023 based on ISO/IEC 17025. According to the mapping analysis, a total of 29 documents were created, including quality manuals, procedures, and test guidelines for the operation of the test laboratory. As a result of the study, a test laboratory management system was developed using Confluence 6.15 software by applying the analyzed results of the overall requirements. The test procedures, documents, and records were stored in, and operated from, this system. Verification of suitability for operation of the test laboratory was conducted by KOLAS evaluators through a document review and an on-site audit at the LG Electronics SW Accredited Test Laboratory in Seoul. In conclusion, it was confirmed through the KOLAS evaluation that the test laboratory management system and the operation of the test laboratory are appropriate and, compared with previous cases, the test laboratory operates effectively, and the overall schedule of accreditation could be shortened.

Statistical Estimation of Specified Concrete Strength by Applying Non-Destructive Test Data (비파괴시험 자료를 적용한 콘크리트 기준강도의 통계적 추정)

  • Paik, Inyeol
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2015
  • The aim of the paper is to introduce the statistical definition of the specified compressive strength of the concrete to be used for safety evaluation of the existing structure in domestic practice and to present the practical method to obtain the specified strength by utilizing the non-destructive test data as well as the limited number of core test data. The statistical definition of the specified compressive strength of concrete in the design codes is reviewed and the consistent formulations to statistically estimate the specified strength for assessment are described. In order to prevent estimating an unrealistically small value of the specified strength due to limited number of data, it is proposed that the information from the non-destructive test data is combined to that of the minimum core test data. The the sample mean, standard deviation and total number of concrete test are obtained from combined test data. The proposed procedures are applied to an example test data composed of the artificial numerical values and the actual evaluation data collected from the bridge assessment reports. The calculation results show that the proposed statistical estimation procedures yield reasonable values of the specified strength for assessment by applying the non-destructive test data in addition to the limited number of core test data.

Reliability Analysis of Degradation Data for LEDs (LED 열화데이터의 신뢰성 분석)

  • Park, Chang-Kyu
    • Journal of Applied Reliability
    • /
    • v.9 no.1
    • /
    • pp.59-69
    • /
    • 2009
  • LEDs have rapidly replaced old light devices such as incandescent or fluorescent lamps, and have been widely applied in general lighting, signals, automobile, signs and others. Since LEDs are for both indoor and outdoor use, temperature and humidity inevitably affect its reliability. We explain the result of the degradation life test on LEDs, and guide to reliability analysis procedure. Analysis on reliability measures are performed by Weibull++6 program, and a common shape parameter of Weibull distribution on the LED is suggested. Also, we make a description of reliability analysis procedures for the degradation data using collected test data from degradation tests. Reliability analysis procedures are consisted of estimating degradation models and failure time, verifying of distribution and parameters of the distribution, and estimating of reliability measures. Finally, this paper suggests reliability analysis method for light characteristics on LEDs.

  • PDF

Classification for intraclass correlation pattern by principal component analysis

  • Chung, Hie-Choon;Han, Chien-Pai
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.3
    • /
    • pp.589-595
    • /
    • 2010
  • In discriminant analysis, we consider an intraclass correlation pattern by principal component analysis. We assume that the two populations are equally likely and the costs of misclassification are equal. In this situation, we consider two procedures, i.e., the test and proportion procedures, for selecting the principal components in classifica-tion. We compare the regular classification method and the proposed two procedures. We consider two methods for estimating error rate, i.e., the leave-one-out method and the bootstrap method.

Establish Selection Process of Performance Management Medical Devices and Test items Based on Risk Management (위험관리기반의 성능관리 의료기기 선정 절차 수립 및 시험 항목 도출)

  • Park, Ho Joon;Jang, Joong Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.20-31
    • /
    • 2019
  • Medical device performance management is an activity that allows a device to be safely used and maintained even after it is put on the market. The purpose of this study is to provide procedures and criteria for selection of medical device items that should manage the safety and performance among medical devices in hospital. Investigate the performance management status of medical devices in hospitals and identify the performance management status by domestic and advanced regulatory agencies. Provides selection procedures and test methods for medical devices subject to performance management in hospitals based on medical device risk management and reliability. In addition, a case study on drug infusion pumps was conducted.

Comparison of Sanitary Codes of Retail Eood Establishments of Korea, (한국, 일본, 중국, 미국의 식품위생법 비교)

  • Roh Pyong-Ui;Bin Sung-Oh
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.2
    • /
    • pp.103-113
    • /
    • 2005
  • Sanitary codes of retail ffod establishment of Korea, Japan, China, and America were reviewed in order to figure out the differences of the codes. The codes of Korea & Japan are similar in many aspects. The code of America regulates food safety procedures in detail and are easy to interpret. The code of China is broad and not specific in the procedures. Korean code deals with many administration affairs and Japanese code deals with food test and business. Chinese code also deals with administration and standards. American code defines 90 different terms while the codes of rest of the countries define only few terms. For sanitization American code specifies the procedures in specific terms in detail but others do not specify the procedures. For facilities, the American code specifies location, material and procedures but other codes also specify the material but the contents of the codes are not so much specific to compare with American code.